Review



beckman i7 automated liquid handler platform  (Danaher Inc)


Bioz Verified Symbol Danaher Inc is a verified supplier
Bioz Manufacturer Symbol Danaher Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    Danaher Inc beckman i7 automated liquid handler platform

    Beckman I7 Automated Liquid Handler Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 362 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/pmc11872463-398-9-15
    Average 96 stars, based on 362 article reviews
    beckman i7 automated liquid handler platform - by Bioz Stars, 2026-10
    96/100 stars

    Images

    1) Product Images from "Identification of a group of 9-amino-acridines that selectively downregulate regulatory T cell functions through FoxP3"

    Article Title: Identification of a group of 9-amino-acridines that selectively downregulate regulatory T cell functions through FoxP3

    Journal: iScience

    doi: 10.1016/j.isci.2025.111931


    Figure Legend Snippet:

    Techniques Used: Control, Binding Assay, Staining, Virus, Recombinant, Avidin-Biotin Assay, Cell Isolation, Activation Assay, Amplified Luminescent Proximity Homogenous Assay, cDNA Synthesis, ChIP-qPCR, Software

    Related Articles

    High Content Screening:

    Article Title: High-throughput, amplification-free detection of endogenous gene expression perturbations via fluorescence anisotropy.
    Article Snippet: Luminescence readout (Agilent BioTek Synergy Neo2) from drug treated wells were normalized against control wells and expressed as percentage cell viability. .. REAGENT or RESOURCE SOURCE IDENTIFIER Other TransBlot Turbo System Bio-Rad N/A BioTek Synergy Neo2 microplate reader Agilent Cat #N2MABT-SN Opera Phenix Plus High Content Screening System Revvity N/A Echo555 acoustic liquid transfer system Beckman Coulter N/A BioTek MultiFlo Dispenser Agilent N/A Biomek i7 automated workstation Beckman Coulter N/A Nanodrop spectrophotometer Thermo Fisher Scientific N/A 384-well Small VolumeTM HiBase Microplate Greiner Cat# 784076 e3 Cell Reports Methods 6, 101616, December 21, 2026 Article ll OPEN ACCESS ..

    Automated:

    Article Title: High-throughput, amplification-free detection of endogenous gene expression perturbations via fluorescence anisotropy.
    Article Snippet: Luminescence readout (Agilent BioTek Synergy Neo2) from drug treated wells were normalized against control wells and expressed as percentage cell viability. .. REAGENT or RESOURCE SOURCE IDENTIFIER Other TransBlot Turbo System Bio-Rad N/A BioTek Synergy Neo2 microplate reader Agilent Cat #N2MABT-SN Opera Phenix Plus High Content Screening System Revvity N/A Echo555 acoustic liquid transfer system Beckman Coulter N/A BioTek MultiFlo Dispenser Agilent N/A Biomek i7 automated workstation Beckman Coulter N/A Nanodrop spectrophotometer Thermo Fisher Scientific N/A 384-well Small VolumeTM HiBase Microplate Greiner Cat# 784076 e3 Cell Reports Methods 6, 101616, December 21, 2026 Article ll OPEN ACCESS ..

    Article Title: Species-specific liver microtissues reveal divergent adverse responses to fialuridine treatment
    Article Snippet: .. In brief, total RNA from a single microtissue was extracted using Biomek i7 Automated Workstation with dual head (Beckman Coulter, CA, USA) combined with an RNAdvance Tissue Total RNA Isolation Kit AR TIC LE IN PR ES S (Beckman Coulter). .. Sequencing libraries were generated using the Corall Library Prep Kit (Lexogen, Vienna, Austria) with mRNA capture module (i.e., selection for poly(A) transcripts).

    Article Title: Pharmacologically targeting CDK12 induces BRCAness and synergizes with merestinib to exacerbate DNA damage in high-risk neuroblastoma.
    Article Snippet: CDK12-targeting compounds BSJ-4-116 and SR-4835 were added at GI50 concentrations using a 4000x concentration (10 nL, final DMSO concentration of 0.025%) using the D300e digital dispenser (Tecan). .. Subsequently, 100 nL of each compound within the Máxima library (in DMSO or saline) was added to the wells using the Biomek i7 Automated Workstation (Beckman Coulter) and Echo 550 acoustic liquid handler (Beckman Coulter) yielding final concentrations of 0.1, 1, 10, 100, 1000 and 10000 nM (additional 0.25% DMSO or saline) (Table S4). ..

    Article Title: eDNA Analysis for Native Cavity‐Nesting Bee Ecology: A Comparison of Data From Brood Cells Contents and Larval DNA
    Article Snippet: .. Extracted DNA templates (2 μL) were dispensed into pre- made PCR1 96- well plates using the Biomek I7 Automated Workstation (Beckman Coulter). ..

    Spectrophotometry:

    Article Title: High-throughput, amplification-free detection of endogenous gene expression perturbations via fluorescence anisotropy.
    Article Snippet: Luminescence readout (Agilent BioTek Synergy Neo2) from drug treated wells were normalized against control wells and expressed as percentage cell viability. .. REAGENT or RESOURCE SOURCE IDENTIFIER Other TransBlot Turbo System Bio-Rad N/A BioTek Synergy Neo2 microplate reader Agilent Cat #N2MABT-SN Opera Phenix Plus High Content Screening System Revvity N/A Echo555 acoustic liquid transfer system Beckman Coulter N/A BioTek MultiFlo Dispenser Agilent N/A Biomek i7 automated workstation Beckman Coulter N/A Nanodrop spectrophotometer Thermo Fisher Scientific N/A 384-well Small VolumeTM HiBase Microplate Greiner Cat# 784076 e3 Cell Reports Methods 6, 101616, December 21, 2026 Article ll OPEN ACCESS ..

    Tissue:

    Article Title: Species-specific liver microtissues reveal divergent adverse responses to fialuridine treatment
    Article Snippet: .. In brief, total RNA from a single microtissue was extracted using Biomek i7 Automated Workstation with dual head (Beckman Coulter, CA, USA) combined with an RNAdvance Tissue Total RNA Isolation Kit AR TIC LE IN PR ES S (Beckman Coulter). .. Sequencing libraries were generated using the Corall Library Prep Kit (Lexogen, Vienna, Austria) with mRNA capture module (i.e., selection for poly(A) transcripts).

    Isolation:

    Article Title: Species-specific liver microtissues reveal divergent adverse responses to fialuridine treatment
    Article Snippet: .. In brief, total RNA from a single microtissue was extracted using Biomek i7 Automated Workstation with dual head (Beckman Coulter, CA, USA) combined with an RNAdvance Tissue Total RNA Isolation Kit AR TIC LE IN PR ES S (Beckman Coulter). .. Sequencing libraries were generated using the Corall Library Prep Kit (Lexogen, Vienna, Austria) with mRNA capture module (i.e., selection for poly(A) transcripts).

    Sequencing:

    Article Title: RNase-mediated defence and its association with SCCmec in Staphylococcus aureus.
    Article Snippet: S. aureus DNA was purified using the Agencourt AMPure XP kit (Beckman Coulter, Brea, CA, USA) according to the manufacturer’s protocol. .. Sequencing libraries were prepared using Enzymatic 5 ×WGS reagents (BioStream, Tokyo, Japan) on a Biomek i7 Workstation (Beckman Coulter). .. Paired-end reads (2 × 150bp) were generated using an Illumina HiSeq X Five platform (Macrogen, Tokyo, Japan).

    Whole Complete genome sequencing:

    Article Title: RNase-mediated defence and its association with SCCmec in Staphylococcus aureus.
    Article Snippet: S. aureus DNA was purified using the Agencourt AMPure XP kit (Beckman Coulter, Brea, CA, USA) according to the manufacturer’s protocol. .. Sequencing libraries were prepared using Enzymatic 5 ×WGS reagents (BioStream, Tokyo, Japan) on a Biomek i7 Workstation (Beckman Coulter). .. Paired-end reads (2 × 150bp) were generated using an Illumina HiSeq X Five platform (Macrogen, Tokyo, Japan).

    Saline:

    Article Title: Pharmacologically targeting CDK12 induces BRCAness and synergizes with merestinib to exacerbate DNA damage in high-risk neuroblastoma.
    Article Snippet: CDK12-targeting compounds BSJ-4-116 and SR-4835 were added at GI50 concentrations using a 4000x concentration (10 nL, final DMSO concentration of 0.025%) using the D300e digital dispenser (Tecan). .. Subsequently, 100 nL of each compound within the Máxima library (in DMSO or saline) was added to the wells using the Biomek i7 Automated Workstation (Beckman Coulter) and Echo 550 acoustic liquid handler (Beckman Coulter) yielding final concentrations of 0.1, 1, 10, 100, 1000 and 10000 nM (additional 0.25% DMSO or saline) (Table S4). ..

    Extraction:

    Article Title: Apparentness of Unseen Rejection Episodes Post Lung rLTx Is Reliably Enabled by ddcfDNA Detection.
    Article Snippet: .. Extraction was done using GenFind V3 Reagent Kit 384 preps (Beckman Coulter, Brea, USA) with Biomek i7 robot (Beckman Coulter) according to the manufacturer's instructions. .. gDNA concentration was determined using Qubit 1X dsDNA Assay- Kit with High Sensitivity (HS) (Thermo Fisher Scientific, Waltham, USA) by measurement on Qubit Flex Fluorometer (Thermo Fisher Scientific) and diluted to 1 ng/μL with Dilution buffer (Devyser, Stockholm, Sweden) for library preparation.

    96 Well Plates:

    Article Title: eDNA Analysis for Native Cavity‐Nesting Bee Ecology: A Comparison of Data From Brood Cells Contents and Larval DNA
    Article Snippet: .. Extracted DNA templates (2 μL) were dispensed into pre- made PCR1 96- well plates using the Biomek I7 Automated Workstation (Beckman Coulter). ..

    Article Title: Proteome-guided drug discovery maps and mitigates therapeutic degrader toxicity.
    Article Snippet: .. HepG2 cells were cultivated and treated in 96-well plates, followed by semi-automated sample preparation using a liquid-handling robot (i7; Beckmann Coulter) to generate tryptic peptides26. .. Peptides were extracted and cleaned using solid-phase extraction, followed by separation using analytical flow-rate chromatography at flow rates of 500 and 800 μl min−1 using Infinity II systems (Agilent Technologies) to achieve fast runtimes, fast column regeneration and maximize reproducibility of peptide separation (Methods).

    Sample Prep:

    Article Title: Proteome-guided drug discovery maps and mitigates therapeutic degrader toxicity.
    Article Snippet: .. HepG2 cells were cultivated and treated in 96-well plates, followed by semi-automated sample preparation using a liquid-handling robot (i7; Beckmann Coulter) to generate tryptic peptides26. .. Peptides were extracted and cleaned using solid-phase extraction, followed by separation using analytical flow-rate chromatography at flow rates of 500 and 800 μl min−1 using Infinity II systems (Agilent Technologies) to achieve fast runtimes, fast column regeneration and maximize reproducibility of peptide separation (Methods).

    Amplification:

    Article Title: Fermented food matrix influences gut microbiota responses in mice
    Article Snippet: The plate was spun briefly, and amplification was performed according to the 16S metagenomic library preparation guide (Illumina) with 30 cycles in place of 25. .. Following amplification, the volume of each sample was increased to 20 μl using molecular grade water and the samples were cleaned using a 0.8 X ratio of Ampure beads (Beckman Coulter) on a Biomek i7 (Beckman Coulter). .. The index PCR was again set up using the Echo 525 to dispense the reagents as follows: 1 μl cleaned PCR product, 2 μl Unique Dual Indices (IDT), 5 μl KapaHifiHotStart ReadyMix, 2 μlmolecular gradewater.



    Similar Products

    96
    Danaher Inc biomek i7 platform
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Biomek I7 Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/bio_rxiv__64898__2025__12__13__694144-27-14-21
    Average 96 stars, based on 1 article reviews
    biomek i7 platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc biomek i7 liquid handling platform
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Biomek I7 Liquid Handling Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/pm40865518-570-15-13
    Average 96 stars, based on 1 article reviews
    biomek i7 liquid handling platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc biomek i7 robotic pipetting platform
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Biomek I7 Robotic Pipetting Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/pmc12491457-324-11-16
    Average 96 stars, based on 1 article reviews
    biomek i7 robotic pipetting platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc biomek i5 platform
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Biomek I5 Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i5+Automated+Workstation/pm40697012-66-1-4
    Average 96 stars, based on 1 article reviews
    biomek i5 platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc liquid handling robot platform
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Liquid Handling Robot Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/pmc12380616__41375_2025_2707_MOESM1_ESM-6-8-14
    Average 96 stars, based on 1 article reviews
    liquid handling robot platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc biomek i5 automated liquid handling platform
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Biomek I5 Automated Liquid Handling Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i5+Automated+Workstation/pm40505827-128-25-31
    Average 96 stars, based on 1 article reviews
    biomek i5 automated liquid handling platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc biomek i7 automated workstation
    A. Hardware layout of the <t>Biomek</t> <t>i7</t> Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.
    Biomek I7 Automated Workstation, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/custom%40aut-bio-i7%4040435495
    Average 96 stars, based on 1 article reviews
    biomek i7 automated workstation - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    96
    Danaher Inc beckman i7 automated liquid handler platform

    Beckman I7 Automated Liquid Handler Platform, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/Biomek+i7+Automated+Workstation/pmc11872463-398-9-15
    Average 96 stars, based on 1 article reviews
    beckman i7 automated liquid handler platform - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    90
    Tecan Systems automated liquid handler platform freedom evo 100

    Automated Liquid Handler Platform Freedom Evo 100, supplied by Tecan Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/liquid+handler+platforms/tecan+robot/pmc12163217-120-2-8
    Average 90 stars, based on 1 article reviews
    automated liquid handler platform freedom evo 100 - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    A. Hardware layout of the Biomek i7 Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.

    Journal: bioRxiv

    Article Title: Automation workflow for high-throughput arrayed plasmid DNA preparation and quantification

    doi: 10.64898/2025.12.13.694144

    Figure Lengend Snippet: A. Hardware layout of the Biomek i7 Hybrid automated workstation. B. Schematic overview of arrayed bacterial inoculation. ① Four empty 96-deep-well plates were initially placed on the Biomek deck. ② 1.2 mL of terrific broth (TB) were transferred from reservoirs to the 96-deep-well plates using the 96-channel pipette head. ③ Four 96-well round-bottom plates containing freshly thawed bacteria glycerol stocks were transferred to the Biomek i7 deck via the servo shuttle and track gripper. The lids were removed and placed on the deck by the gripper. ④ 50 µL of bacteria glycerol solution was transferred from the round-bottom plates to the deep-well plates and mixed thoroughly using the 96-channel pipette head. ⑤ The lids were replaced, and the plates containing leftover bacterial glycerol stocks were returned to the incubator. C. Pipeline overview under the SAMI EX interface. SAMI EX software was utilized for the method creation and pipeline design. D. SAMI’s scheduling and time estimation for the pipeline illustrated the chronological timestamps of each labware. E. The labware setup report provided a reference point and summarizes the SAMI EX deck layout, labware, and associated conditions.

    Article Snippet: The automation workflow for high throughput arrayed plasmid DNA preparation and quantification on the Biomek i7 platform was established using the Beckman Coulter software suite.

    Techniques: Transferring, Bacteria, Software

    A. Schematic overview of arrayed plasmid isolation using Biomek i7 liquid handler and BioShake. ① RES buffer was transferred from a reservoir to a 96-deep-well plate containing dry bacterial pellets on the Biomek deck. ② The plate was moved to the shaker by the gripper for vortexing, followed by pipetting up and down using the 96-channel pipette head to fully resuspend the bacteria. ③ LYS buffer was then transferred from a reservoir to the plate, followed by pipetting up and down to ensure complete bacterial lysis. ④ NEU buffer was added from a reservoir to the plate, followed by pipetting up and down to neutralize the alkaline lysate. Biomek 5 method node: asterisk symbol; SAMI EX method node: black dot symbol. B. Pipeline overview under the SAMI EX interface. Both SAMI EX and Biomek 5 software were utilized for the method development. C. Scheduling and time estimation of the entire pipeline in SAMI EX, showing the chronological timestamps of each labware item. D. Deck layout for RES buffer transfer and plate vortexing, indicated by the asterisk in . E. Biomek 5 method for RES buffer transfer and plate vortexing (asterisk in ). F. Labware setup report, indicated by the dagger symbol in , providing an overview of the SAMI EX deck layout, including labware details and conditions.

    Journal: bioRxiv

    Article Title: Automation workflow for high-throughput arrayed plasmid DNA preparation and quantification

    doi: 10.64898/2025.12.13.694144

    Figure Lengend Snippet: A. Schematic overview of arrayed plasmid isolation using Biomek i7 liquid handler and BioShake. ① RES buffer was transferred from a reservoir to a 96-deep-well plate containing dry bacterial pellets on the Biomek deck. ② The plate was moved to the shaker by the gripper for vortexing, followed by pipetting up and down using the 96-channel pipette head to fully resuspend the bacteria. ③ LYS buffer was then transferred from a reservoir to the plate, followed by pipetting up and down to ensure complete bacterial lysis. ④ NEU buffer was added from a reservoir to the plate, followed by pipetting up and down to neutralize the alkaline lysate. Biomek 5 method node: asterisk symbol; SAMI EX method node: black dot symbol. B. Pipeline overview under the SAMI EX interface. Both SAMI EX and Biomek 5 software were utilized for the method development. C. Scheduling and time estimation of the entire pipeline in SAMI EX, showing the chronological timestamps of each labware item. D. Deck layout for RES buffer transfer and plate vortexing, indicated by the asterisk in . E. Biomek 5 method for RES buffer transfer and plate vortexing (asterisk in ). F. Labware setup report, indicated by the dagger symbol in , providing an overview of the SAMI EX deck layout, including labware details and conditions.

    Article Snippet: The automation workflow for high throughput arrayed plasmid DNA preparation and quantification on the Biomek i7 platform was established using the Beckman Coulter software suite.

    Techniques: Plasmid Preparation, Isolation, Transferring, Bacteria, Lysis, Software

    A. Schematic overview of arrayed plasmid DNA purification using the Biomek i7 liquid handler, BioShake, microplate centrifuge, and magnetic plate. All steps (① - ⑬) were performed within the Biomek i7 system. ① Molecular-grade water was added to the 96-deep-well plate containing dry DNA pellets. ② The plate was transferred to the BioShake for vortexing.③ The plate was transferred to the centrifuge to spin down DNA suspension. ④ The plate was returned to the BioShake and remained there for the next two steps. ⑤ Bead buffer was added to the plate, and then vortexed. ⑥ Bead solution was added to the plate, followed by vortexing and incubation to enable DNA-bead binding. ⑦ The plate was transferred to the centrifuge for a brief spin-down. ⑧ The plate was placed on the magnetic plate for DNA-bead isolation and remained there for the subsequent steps, except step 10. ⑨ After liquid removal by pipetting, 70% ethanol (ETOH) was added to the plate for DNA washing, followed by liquid removal and a repeat wash. ⑩ After removing the second wash, the plate was transferred from the magnetic plate to the pre-warmed BioShake. ⑪ TE buffer was added to the plate, followed by vortexing and incubation on the BioShake for DNA elution. ⑫ The plate was then placed back onto the magnetic plate for DNA-bead separation. ⑬ The supernatant containing plasmid DNA was transferred to a new 96-well conical-bottom plate, followed by a secondary transfer to another plate to remove any residual beads. B. Pipeline overview displayed in the SAMI EX interface. Method development and pipeline design were performed using the SAMI EX and Biomek 5 software platforms. C. SAMI EX provides scheduling and time estimation for the entire pipeline, displaying the chronological timestamps for each labware item. D. Overview and deck layout of the three Biomek 5 methods: buffer and bead treatment for DNA-bead binding (top-left panel), ethanol wash and TE addition for DNA washing and elution (right panel), and DNA solution clarification through bead removal (bottom-left panel), as indicated by the asterisk in . E. The labware setup report, marked by the dagger symbol in , outlines the SAMI EX deck layout and labware conditions.

    Journal: bioRxiv

    Article Title: Automation workflow for high-throughput arrayed plasmid DNA preparation and quantification

    doi: 10.64898/2025.12.13.694144

    Figure Lengend Snippet: A. Schematic overview of arrayed plasmid DNA purification using the Biomek i7 liquid handler, BioShake, microplate centrifuge, and magnetic plate. All steps (① - ⑬) were performed within the Biomek i7 system. ① Molecular-grade water was added to the 96-deep-well plate containing dry DNA pellets. ② The plate was transferred to the BioShake for vortexing.③ The plate was transferred to the centrifuge to spin down DNA suspension. ④ The plate was returned to the BioShake and remained there for the next two steps. ⑤ Bead buffer was added to the plate, and then vortexed. ⑥ Bead solution was added to the plate, followed by vortexing and incubation to enable DNA-bead binding. ⑦ The plate was transferred to the centrifuge for a brief spin-down. ⑧ The plate was placed on the magnetic plate for DNA-bead isolation and remained there for the subsequent steps, except step 10. ⑨ After liquid removal by pipetting, 70% ethanol (ETOH) was added to the plate for DNA washing, followed by liquid removal and a repeat wash. ⑩ After removing the second wash, the plate was transferred from the magnetic plate to the pre-warmed BioShake. ⑪ TE buffer was added to the plate, followed by vortexing and incubation on the BioShake for DNA elution. ⑫ The plate was then placed back onto the magnetic plate for DNA-bead separation. ⑬ The supernatant containing plasmid DNA was transferred to a new 96-well conical-bottom plate, followed by a secondary transfer to another plate to remove any residual beads. B. Pipeline overview displayed in the SAMI EX interface. Method development and pipeline design were performed using the SAMI EX and Biomek 5 software platforms. C. SAMI EX provides scheduling and time estimation for the entire pipeline, displaying the chronological timestamps for each labware item. D. Overview and deck layout of the three Biomek 5 methods: buffer and bead treatment for DNA-bead binding (top-left panel), ethanol wash and TE addition for DNA washing and elution (right panel), and DNA solution clarification through bead removal (bottom-left panel), as indicated by the asterisk in . E. The labware setup report, marked by the dagger symbol in , outlines the SAMI EX deck layout and labware conditions.

    Article Snippet: The automation workflow for high throughput arrayed plasmid DNA preparation and quantification on the Biomek i7 platform was established using the Beckman Coulter software suite.

    Techniques: Plasmid Preparation, DNA Purification, Suspension, Incubation, Binding Assay, Isolation, Software, Clarification Assay

    A. Overview of arrayed plasmid DNA quantification using the Biomek i7 liquid handler and microplate centrifuge. All steps (① - ⑩) were performed within the Biomek i7 system. ① A 96-well plate containing 2 ng/µL standard DNA in well A1 and PicoGreen reagent in columns 2-4 was designated as the reagent plate. TE buffer, stored in a reservoir, was used as the diluent to perform a six-point, three-fold serial dilution from wells A1 to G1 in column 1. The negative control well, H1, contained TE buffer without DNA. ② Twenty microliters of the serially diluted DNA and TE buffer in column 1 were transferred from the reagent plate to the quadruple 1 (Q1) well positions in columns 1, 3, and 5 of a new 384-well assay plate as the standard and negative controls, each in triplicate. ③ TE buffer was transferred from the reservoir to a new 96-well conical-bottom plate (designated as the 1:20 dilution plate) to serve as the diluent for the first DNA sample dilution. ④ TE buffer was also transferred from the reservoir to another 96-well conical-bottom plate (designated as the 1:400 dilution plate) to serve as the diluent for the second dilution. ⑤ Purified plasmid DNA samples in a 96-well plate were transferred to the 1:20 dilution plate to generate an intermediate dilution stock. ⑥ The intermediately diluted DNA was transferred to the 1:400 dilution plate to achieve the final dilution. ⑦ The final diluted DNA samples from the 1:400 dilution plate were transferred to the Q3 and Q4 wells of the assay plate in duplicate. ⑧ PicoGreen reagent was transferred from the reagent plate to the Q1, Q3, and Q4 well positions of the assay plate. ⑨ The assay plate was subjected to a brief spin-down. ⑩ The assay plate was then placed on the BioShake for sample mixing prior to measurement. B. Pipeline overview as displayed in the SAMI EX interface. Method development and pipeline design were carried out using the SAMI EX and Biomek 5 software. C. SAMI EX generated a schedule and time estimate for the entire pipeline, including chronological timestamps for each labware item. D. Overview and deck layout of the four Biomek 5 methods: serial dilution of the standard DNA (top-left panel), spotting of the standard and negative controls (bottom-left panel), dilution of the plasmid DNA samples (top-right panel), and dispensing of the PicoGreen reagent (bottom-right panel), as indicated by the asterisk in . E. The labware setup report, marked by the dagger in , outlines the SAMI EX deck layout and labware conditions.

    Journal: bioRxiv

    Article Title: Automation workflow for high-throughput arrayed plasmid DNA preparation and quantification

    doi: 10.64898/2025.12.13.694144

    Figure Lengend Snippet: A. Overview of arrayed plasmid DNA quantification using the Biomek i7 liquid handler and microplate centrifuge. All steps (① - ⑩) were performed within the Biomek i7 system. ① A 96-well plate containing 2 ng/µL standard DNA in well A1 and PicoGreen reagent in columns 2-4 was designated as the reagent plate. TE buffer, stored in a reservoir, was used as the diluent to perform a six-point, three-fold serial dilution from wells A1 to G1 in column 1. The negative control well, H1, contained TE buffer without DNA. ② Twenty microliters of the serially diluted DNA and TE buffer in column 1 were transferred from the reagent plate to the quadruple 1 (Q1) well positions in columns 1, 3, and 5 of a new 384-well assay plate as the standard and negative controls, each in triplicate. ③ TE buffer was transferred from the reservoir to a new 96-well conical-bottom plate (designated as the 1:20 dilution plate) to serve as the diluent for the first DNA sample dilution. ④ TE buffer was also transferred from the reservoir to another 96-well conical-bottom plate (designated as the 1:400 dilution plate) to serve as the diluent for the second dilution. ⑤ Purified plasmid DNA samples in a 96-well plate were transferred to the 1:20 dilution plate to generate an intermediate dilution stock. ⑥ The intermediately diluted DNA was transferred to the 1:400 dilution plate to achieve the final dilution. ⑦ The final diluted DNA samples from the 1:400 dilution plate were transferred to the Q3 and Q4 wells of the assay plate in duplicate. ⑧ PicoGreen reagent was transferred from the reagent plate to the Q1, Q3, and Q4 well positions of the assay plate. ⑨ The assay plate was subjected to a brief spin-down. ⑩ The assay plate was then placed on the BioShake for sample mixing prior to measurement. B. Pipeline overview as displayed in the SAMI EX interface. Method development and pipeline design were carried out using the SAMI EX and Biomek 5 software. C. SAMI EX generated a schedule and time estimate for the entire pipeline, including chronological timestamps for each labware item. D. Overview and deck layout of the four Biomek 5 methods: serial dilution of the standard DNA (top-left panel), spotting of the standard and negative controls (bottom-left panel), dilution of the plasmid DNA samples (top-right panel), and dispensing of the PicoGreen reagent (bottom-right panel), as indicated by the asterisk in . E. The labware setup report, marked by the dagger in , outlines the SAMI EX deck layout and labware conditions.

    Article Snippet: The automation workflow for high throughput arrayed plasmid DNA preparation and quantification on the Biomek i7 platform was established using the Beckman Coulter software suite.

    Techniques: Plasmid Preparation, Serial Dilution, Negative Control, Purification, Software, Generated

    A. Plasmid DNA quantities from five 96-well plates (480 samples from the T. gonfio library), generated using the Biomek i7 and measured by the NanoDrop, are presented as overlapping scatter and box plots. The median value is indicated by a red line, and the green box denotes the interquartile range. The gray solid line marks the high-titer threshold of 10 µg of DNA. B. Comparison of DNA concentration measurements between the NanoDrop and PicoGreen assay across four 96-well plates. The median is shown in red, while the gray solid line represents the 10 µg DNA threshold. C. Scatter plots depicting the correlation (R²) between DNA concentrations measured by the NanoDrop and the PicoGreen assay across four plates. The values on the X- and Y-axes represent individual DNA concentrations measured by the two methods. D. Gel electrophoresis image showing the migration pattern of equal amounts of plasmid DNA (60 ng per lane) after PicoGreen-based concentration normalization, alongside 1 kb DNA ladders. The intensities of the 6 kb and 8 kb ladder bands each represent 2.8 ng of DNA.

    Journal: bioRxiv

    Article Title: Automation workflow for high-throughput arrayed plasmid DNA preparation and quantification

    doi: 10.64898/2025.12.13.694144

    Figure Lengend Snippet: A. Plasmid DNA quantities from five 96-well plates (480 samples from the T. gonfio library), generated using the Biomek i7 and measured by the NanoDrop, are presented as overlapping scatter and box plots. The median value is indicated by a red line, and the green box denotes the interquartile range. The gray solid line marks the high-titer threshold of 10 µg of DNA. B. Comparison of DNA concentration measurements between the NanoDrop and PicoGreen assay across four 96-well plates. The median is shown in red, while the gray solid line represents the 10 µg DNA threshold. C. Scatter plots depicting the correlation (R²) between DNA concentrations measured by the NanoDrop and the PicoGreen assay across four plates. The values on the X- and Y-axes represent individual DNA concentrations measured by the two methods. D. Gel electrophoresis image showing the migration pattern of equal amounts of plasmid DNA (60 ng per lane) after PicoGreen-based concentration normalization, alongside 1 kb DNA ladders. The intensities of the 6 kb and 8 kb ladder bands each represent 2.8 ng of DNA.

    Article Snippet: The automation workflow for high throughput arrayed plasmid DNA preparation and quantification on the Biomek i7 platform was established using the Beckman Coulter software suite.

    Techniques: Plasmid Preparation, Generated, Comparison, Concentration Assay, Picogreen Assay, Nucleic Acid Electrophoresis, Migration

    Journal: iScience

    Article Title: Identification of a group of 9-amino-acridines that selectively downregulate regulatory T cell functions through FoxP3

    doi: 10.1016/j.isci.2025.111931

    Figure Lengend Snippet:

    Article Snippet: All the liquid handling procedures were performed by the Beckman i7 Automated Liquid Handler platform (Beckman Coulter).

    Techniques: Control, Binding Assay, Staining, Virus, Recombinant, Avidin-Biotin Assay, Cell Isolation, Activation Assay, Amplified Luminescent Proximity Homogenous Assay, cDNA Synthesis, ChIP-qPCR, Software