    Structured Review

    ADInstruments single lead body surface ecg signals
    Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the <t>ECG</t> cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.
    Single Lead Body Surface Ecg Signals, supplied by ADInstruments, used in various techniques. Bioz Stars score: 99/100, based on 8135 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/PowerLab/pmc10762020-207-0-18
    Average 99 stars, based on 8135 article reviews
    single lead body surface ecg signals - by Bioz Stars, 2026-11
    99/100 stars

    Images

    1) Product Images from "Open-source software for respiratory rate estimation using single-lead electrocardiograms"

    Article Title: Open-source software for respiratory rate estimation using single-lead electrocardiograms

    Journal: Scientific Reports

    doi: 10.1038/s41598-023-50470-0

    Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the ECG cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.
    Figure Legend Snippet: Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the ECG cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.

    Techniques Used: Comparison

    Block diagram of respiration rate estimation algorithm. Raw single-lead ECG data are filtered (panels a and b ), R-peaks are detected (red symbols, panel c ), R-peak intervals are determined, QRS complexes are extracted (panel d ) and their root mean square amplitude (RMS) values are calculated (panel e ), a power spectrum is generated for a moving window of 16 QRS RMS values incremented one value at a time (panel f ), and its peak frequency and the R-peak interval data within the window are used to calculate the respiratory rate (RR) using the equation shown.
    Figure Legend Snippet: Block diagram of respiration rate estimation algorithm. Raw single-lead ECG data are filtered (panels a and b ), R-peaks are detected (red symbols, panel c ), R-peak intervals are determined, QRS complexes are extracted (panel d ) and their root mean square amplitude (RMS) values are calculated (panel e ), a power spectrum is generated for a moving window of 16 QRS RMS values incremented one value at a time (panel f ), and its peak frequency and the R-peak interval data within the window are used to calculate the respiratory rate (RR) using the equation shown.

    Techniques Used: Blocking Assay, Generated

    Related Articles

    Software:

    Article Title: Renin–Angiotensin System Activation Drives Early Cardiorenal Dysfunction in Normotensive Prediabetes
    Article Snippet: .. PowerLab hardware and LabChart Pro 8 software (AD Instruments Ltd., Dunedin, New Zealand) were utilised for data acquisition. ..

    Article Title: Channelrhodopsin ion selectivity determines mechanisms and efficacy of optogenetic defibrillation in human atria and ventricles
    Article Snippet: .. Membrane potential signals were fed through a 50/60 Hz noise eliminator (HumBug; Digitimer, Welwyn Garden City, United Kingdom) and recorded at 2 kHz using a software-controlled (LabChart; ADInstruments, Sydney, Australia) analog-to-digital data acquisition system (PowerLab; ADInstruments). ..

    Article Title: Probing the role of left inferior frontal gyrus in vocal motor control: Evidence from TMS and causal inference analysis.
    Article Snippet: .. REAGENT or RESOURCE SOURCE IDENTIFIER Deposited data CIA analysis code This paper https://github.com/zhaoshuhzi/CIA-IFG Software and algorithms G*Power 3.1 Heinrich Heine University Düsseldorf https://www.psychologie.hhu.de/arbeitsgruppen/ allgemeine-psychologie-und-arbeitspsychologie/gpower Visor 2.0 ANT Neuro https://www.ant-neuro.com/products/visor2 Max/MSP 6.1 Cycling ’74 https://cycling74.com/downloads/older LabChart 7.0 ADInstruments https://www.adinstruments.com/labchart NetStation 4.5 Electrical Geodesics Inc. https://www.egi.com/ IGOR Pro 6.0 WaveMetrics Inc. https://www.wavemetrics.com/downloads Praat Boersma https://www.fon.hum.uva.nl/praat/ SPSS 20.0 IBM https://www.ibm.com/products/spss-statistics Brainstorm 3.2 University of Southern California and McGill University https://neuroimage.usc.edu/brainstorm/ OpenMEEG INRIA Sophia-Antipolis https://openmeeg.github.io/ Other MRI scanner (3 T) Siemens Verio TMS stimulator YIRUIDE Co. CCY-I Optical motion tracking system Northern Digital Inc. Polaris Spectra Dynamic microphone Takstar Inc. DM2200 Pitch-shifting processor Eventide Eclipse Harmonizer Audio interface MOTU UltraLite-mk3 FireWire Headphone amplifier ICON NeoAmp Insert earphones Etymotic Research Inc. ER-1 A/D converter ADInstruments PowerLab ML880 Geodesic Sensor Net Electrical Geodesics Inc. N/A EEG amplifier Electrical Geodesics Inc. Net Amps 300 14 iScience 29, 117790, November 20, 2026 .. As a prerequisite for neuronavigated TMS, all participants underwent structural MRI scanning (Siemens Verio 3-T scanner, Germany).

    Article Title: Microglial Ring1 enhances post-phagocytic myelin debris processing: Attenuation of cognitive dysfunction after hemorrhagic shock and reperfusion
    Article Snippet: .. During the subsequent 30-minute hypotension-maintenance period and the 30-minute blood-reinfusion period, MAP was monitored continuously using a PowerLab data acquisition system and LabChart software (ADInstruments, Bella Vista, Australia). ..

    Article Title: The AIM2 inflammasome drives age-dependent cardiac dysfunction following ischemia-reperfusion in mice
    Article Snippet: .. The m ost up-to-date-version is available at doi.org/10.1042/C S20260997 6 maximal first derivative of left ventricular pressure (+dP/dTmax), and minimal first 129 derivative of left ventricular pressure (−dP/dTmin) were constantly monitored and 130 recorded using PowerLab Chart 8 software (AD-Instruments). ..

    Membrane:

    Article Title: Channelrhodopsin ion selectivity determines mechanisms and efficacy of optogenetic defibrillation in human atria and ventricles
    Article Snippet: .. Membrane potential signals were fed through a 50/60 Hz noise eliminator (HumBug; Digitimer, Welwyn Garden City, United Kingdom) and recorded at 2 kHz using a software-controlled (LabChart; ADInstruments, Sydney, Australia) analog-to-digital data acquisition system (PowerLab; ADInstruments). ..

    other:

    Article Title: Lactate-driven histone lactylation by AARS1 promotes pulmonary arterial hypertension.
    Article Snippet: RV systolic pressure (RVSP) was recorded in real-time after stabilization of the pressure waveform using a Powerlab-ML221 data acquisition system (AD Instruments Pvt Ltd, Bella Vista, New South Wales, Australia).

    Article Title: Technical safety and efficacy of PFA catheter electrode for airway ablation in a rat model of COPD.
    Article Snippet: Electrocardiographic (ECG) monitoring was performed using a small animal electrocardiogram monitor (PowerLab DAQ, AD Instruments, Australia).

    Analysis:

    Article Title: Probing the role of left inferior frontal gyrus in vocal motor control: Evidence from TMS and causal inference analysis.
    Article Snippet: .. REAGENT or RESOURCE SOURCE IDENTIFIER Deposited data CIA analysis code This paper https://github.com/zhaoshuhzi/CIA-IFG Software and algorithms G*Power 3.1 Heinrich Heine University Düsseldorf https://www.psychologie.hhu.de/arbeitsgruppen/ allgemeine-psychologie-und-arbeitspsychologie/gpower Visor 2.0 ANT Neuro https://www.ant-neuro.com/products/visor2 Max/MSP 6.1 Cycling ’74 https://cycling74.com/downloads/older LabChart 7.0 ADInstruments https://www.adinstruments.com/labchart NetStation 4.5 Electrical Geodesics Inc. https://www.egi.com/ IGOR Pro 6.0 WaveMetrics Inc. https://www.wavemetrics.com/downloads Praat Boersma https://www.fon.hum.uva.nl/praat/ SPSS 20.0 IBM https://www.ibm.com/products/spss-statistics Brainstorm 3.2 University of Southern California and McGill University https://neuroimage.usc.edu/brainstorm/ OpenMEEG INRIA Sophia-Antipolis https://openmeeg.github.io/ Other MRI scanner (3 T) Siemens Verio TMS stimulator YIRUIDE Co. CCY-I Optical motion tracking system Northern Digital Inc. Polaris Spectra Dynamic microphone Takstar Inc. DM2200 Pitch-shifting processor Eventide Eclipse Harmonizer Audio interface MOTU UltraLite-mk3 FireWire Headphone amplifier ICON NeoAmp Insert earphones Etymotic Research Inc. ER-1 A/D converter ADInstruments PowerLab ML880 Geodesic Sensor Net Electrical Geodesics Inc. N/A EEG amplifier Electrical Geodesics Inc. Net Amps 300 14 iScience 29, 117790, November 20, 2026 .. As a prerequisite for neuronavigated TMS, all participants underwent structural MRI scanning (Siemens Verio 3-T scanner, Germany).

    Magnetic Resonance Imaging:

    Article Title: Probing the role of left inferior frontal gyrus in vocal motor control: Evidence from TMS and causal inference analysis.
    Article Snippet: .. REAGENT or RESOURCE SOURCE IDENTIFIER Deposited data CIA analysis code This paper https://github.com/zhaoshuhzi/CIA-IFG Software and algorithms G*Power 3.1 Heinrich Heine University Düsseldorf https://www.psychologie.hhu.de/arbeitsgruppen/ allgemeine-psychologie-und-arbeitspsychologie/gpower Visor 2.0 ANT Neuro https://www.ant-neuro.com/products/visor2 Max/MSP 6.1 Cycling ’74 https://cycling74.com/downloads/older LabChart 7.0 ADInstruments https://www.adinstruments.com/labchart NetStation 4.5 Electrical Geodesics Inc. https://www.egi.com/ IGOR Pro 6.0 WaveMetrics Inc. https://www.wavemetrics.com/downloads Praat Boersma https://www.fon.hum.uva.nl/praat/ SPSS 20.0 IBM https://www.ibm.com/products/spss-statistics Brainstorm 3.2 University of Southern California and McGill University https://neuroimage.usc.edu/brainstorm/ OpenMEEG INRIA Sophia-Antipolis https://openmeeg.github.io/ Other MRI scanner (3 T) Siemens Verio TMS stimulator YIRUIDE Co. CCY-I Optical motion tracking system Northern Digital Inc. Polaris Spectra Dynamic microphone Takstar Inc. DM2200 Pitch-shifting processor Eventide Eclipse Harmonizer Audio interface MOTU UltraLite-mk3 FireWire Headphone amplifier ICON NeoAmp Insert earphones Etymotic Research Inc. ER-1 A/D converter ADInstruments PowerLab ML880 Geodesic Sensor Net Electrical Geodesics Inc. N/A EEG amplifier Electrical Geodesics Inc. Net Amps 300 14 iScience 29, 117790, November 20, 2026 .. As a prerequisite for neuronavigated TMS, all participants underwent structural MRI scanning (Siemens Verio 3-T scanner, Germany).

    Transcranial Magnetic Stimulation:

    Article Title: Probing the role of left inferior frontal gyrus in vocal motor control: Evidence from TMS and causal inference analysis.
    Article Snippet: .. REAGENT or RESOURCE SOURCE IDENTIFIER Deposited data CIA analysis code This paper https://github.com/zhaoshuhzi/CIA-IFG Software and algorithms G*Power 3.1 Heinrich Heine University Düsseldorf https://www.psychologie.hhu.de/arbeitsgruppen/ allgemeine-psychologie-und-arbeitspsychologie/gpower Visor 2.0 ANT Neuro https://www.ant-neuro.com/products/visor2 Max/MSP 6.1 Cycling ’74 https://cycling74.com/downloads/older LabChart 7.0 ADInstruments https://www.adinstruments.com/labchart NetStation 4.5 Electrical Geodesics Inc. https://www.egi.com/ IGOR Pro 6.0 WaveMetrics Inc. https://www.wavemetrics.com/downloads Praat Boersma https://www.fon.hum.uva.nl/praat/ SPSS 20.0 IBM https://www.ibm.com/products/spss-statistics Brainstorm 3.2 University of Southern California and McGill University https://neuroimage.usc.edu/brainstorm/ OpenMEEG INRIA Sophia-Antipolis https://openmeeg.github.io/ Other MRI scanner (3 T) Siemens Verio TMS stimulator YIRUIDE Co. CCY-I Optical motion tracking system Northern Digital Inc. Polaris Spectra Dynamic microphone Takstar Inc. DM2200 Pitch-shifting processor Eventide Eclipse Harmonizer Audio interface MOTU UltraLite-mk3 FireWire Headphone amplifier ICON NeoAmp Insert earphones Etymotic Research Inc. ER-1 A/D converter ADInstruments PowerLab ML880 Geodesic Sensor Net Electrical Geodesics Inc. N/A EEG amplifier Electrical Geodesics Inc. Net Amps 300 14 iScience 29, 117790, November 20, 2026 .. As a prerequisite for neuronavigated TMS, all participants underwent structural MRI scanning (Siemens Verio 3-T scanner, Germany).

    Electroencephalography:

    Article Title: Probing the role of left inferior frontal gyrus in vocal motor control: Evidence from TMS and causal inference analysis.
    Article Snippet: .. REAGENT or RESOURCE SOURCE IDENTIFIER Deposited data CIA analysis code This paper https://github.com/zhaoshuhzi/CIA-IFG Software and algorithms G*Power 3.1 Heinrich Heine University Düsseldorf https://www.psychologie.hhu.de/arbeitsgruppen/ allgemeine-psychologie-und-arbeitspsychologie/gpower Visor 2.0 ANT Neuro https://www.ant-neuro.com/products/visor2 Max/MSP 6.1 Cycling ’74 https://cycling74.com/downloads/older LabChart 7.0 ADInstruments https://www.adinstruments.com/labchart NetStation 4.5 Electrical Geodesics Inc. https://www.egi.com/ IGOR Pro 6.0 WaveMetrics Inc. https://www.wavemetrics.com/downloads Praat Boersma https://www.fon.hum.uva.nl/praat/ SPSS 20.0 IBM https://www.ibm.com/products/spss-statistics Brainstorm 3.2 University of Southern California and McGill University https://neuroimage.usc.edu/brainstorm/ OpenMEEG INRIA Sophia-Antipolis https://openmeeg.github.io/ Other MRI scanner (3 T) Siemens Verio TMS stimulator YIRUIDE Co. CCY-I Optical motion tracking system Northern Digital Inc. Polaris Spectra Dynamic microphone Takstar Inc. DM2200 Pitch-shifting processor Eventide Eclipse Harmonizer Audio interface MOTU UltraLite-mk3 FireWire Headphone amplifier ICON NeoAmp Insert earphones Etymotic Research Inc. ER-1 A/D converter ADInstruments PowerLab ML880 Geodesic Sensor Net Electrical Geodesics Inc. N/A EEG amplifier Electrical Geodesics Inc. Net Amps 300 14 iScience 29, 117790, November 20, 2026 .. As a prerequisite for neuronavigated TMS, all participants underwent structural MRI scanning (Siemens Verio 3-T scanner, Germany).

    Injection:

    Article Title: The effect of resveratrol on the hippocampus in the pentylenetetrazol (PTZ) - dependent kindling model of epilepsy.
    Article Snippet: .. Recordings from digital electrocorticography were taken for 30 min utilizing the PowerLab data acquisition system (ADInstruments, Sydney, Australia) 24 h following the final injection administered to animals that had received analgesics (Buprenorphine, 0.1 mg/kg) and antibiotics (Ampicillin, 50 mg/kg) during the post-surgical period. ..



    Similar Products

    86
    Philips Healthcare resting 12 lead surface ecg
    Resting 12 Lead Surface Ecg, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/12+ecg+lead/pmc12786989-122-1-6
    Average 86 stars, based on 1 article reviews
    resting 12 lead surface ecg - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Philips Healthcare monitoring • 12 lead surface electrocardiogram
    Monitoring • 12 Lead Surface Electrocardiogram, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/12+ecg+lead/pm41342816-169-25-30
    Average 86 stars, based on 1 article reviews
    monitoring • 12 lead surface electrocardiogram - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Philips Healthcare lead surface ecg
    Lead Surface Ecg, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/12+ecg+lead/pm41084955-48-3-13
    Average 86 stars, based on 1 article reviews
    lead surface ecg - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Fukuda Denshi Co standard 12 lead surface digital ecgs
    Standard 12 Lead Surface Digital Ecgs, supplied by Fukuda Denshi Co, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/12+digital+ecgs+lead+standard+surface/pmc12328242-138-5-37
    Average 86 stars, based on 1 article reviews
    standard 12 lead surface digital ecgs - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Boston Scientific Corporation surface 12 lead ecg p waves
    Surface 12 Lead Ecg P Waves, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/clinical+devices+ecg+grade+lead+single/pm39880539-50-0-23
    Average 86 stars, based on 1 article reviews
    surface 12 lead ecg p waves - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Roche lead surface ecg
    Lead Surface Ecg, supplied by Roche, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/pm38329882-49-8-39
    Average 86 stars, based on 1 article reviews
    lead surface ecg - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    99
    ADInstruments single lead body surface ecg signals
    Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the <t>ECG</t> cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.
    Single Lead Body Surface Ecg Signals, supplied by ADInstruments, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/PowerLab/pmc10762020-207-0-18
    Average 99 stars, based on 1 article reviews
    single lead body surface ecg signals - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    90
    PRUCKA ENGINEERING INC 12-lead surface electrocardiogram (ecg)
    Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the <t>ECG</t> cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.
    12 Lead Surface Electrocardiogram (Ecg), supplied by PRUCKA ENGINEERING INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/12+lead+ecg/pm38151978-38-11-20
    Average 90 stars, based on 1 article reviews
    12-lead surface electrocardiogram (ecg) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Boston Scientific Corporation surface rhythm strips (1-lead ecg)
    Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the <t>ECG</t> cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.
    Surface Rhythm Strips (1 Lead Ecg), supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/lead+surface+ecg/surface+rhythm+strips++1+lead+ecg+/pmc10779836-72-3-21
    Average 90 stars, based on 1 article reviews
    surface rhythm strips (1-lead ecg) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the ECG cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.

    Journal: Scientific Reports

    Article Title: Open-source software for respiratory rate estimation using single-lead electrocardiograms

    doi: 10.1038/s41598-023-50470-0

    Figure Lengend Snippet: Respiratory rate (RR) estimation in spontaneously breathing humans. ( A ) RR estimates, in breaths per minute (bpm), during 3 levels of exercise in one subject. Algorithm-estimated RRs (estimated, blue) are compared with RR measured from the subject using the respiratory inductive plethysmography based Hexoskin monitor (expected, red) while performing three consecutive tasks: (1) resting, standing upright on a treadmill (Int 1); (2) walking on the treadmill at a moderate speed (1.2 m/s) (int 2); and (3) walking on the treadmill with 15% track inclination at the moderate speed (Int 3). ( B ) Summary results of algorithm-estimated and reference RRs (blue and red, respectively) during each subject-task interval. The data are from seven subjects, each performing either or all the three levels of exercise described above (subject-tasks), and presented in order of increasing average expected RR values. ( C ) The absolute errors (black) and relative errors (gray) of the algorithmic RR estimations across the subject-task intervals described above. Equivalence testing revealed that the expected and estimated RRs were the same ( p < 0.0001) for all subject-task intervals. ( D ) A comparison of the ECG cycle-to-cycle estimated and expected RR for all subjects and tasks with the indicated R 2 value (0.9092) and low root mean square error (RMSE, 2.2bpm) support a close linear relationship between the values. ( E ) Absolute error (bpm) and ( F ) relative error (%) distributions across all subjects.

    Article Snippet: Single-lead body surface ECG signals were obtained during the procedure and 90 min after coil placement using the AD Instruments PowerLab 4/35 system with Labchart 8 software.

    Techniques: Comparison

    Block diagram of respiration rate estimation algorithm. Raw single-lead ECG data are filtered (panels a and b ), R-peaks are detected (red symbols, panel c ), R-peak intervals are determined, QRS complexes are extracted (panel d ) and their root mean square amplitude (RMS) values are calculated (panel e ), a power spectrum is generated for a moving window of 16 QRS RMS values incremented one value at a time (panel f ), and its peak frequency and the R-peak interval data within the window are used to calculate the respiratory rate (RR) using the equation shown.

    Journal: Scientific Reports

    Article Title: Open-source software for respiratory rate estimation using single-lead electrocardiograms

    doi: 10.1038/s41598-023-50470-0

    Figure Lengend Snippet: Block diagram of respiration rate estimation algorithm. Raw single-lead ECG data are filtered (panels a and b ), R-peaks are detected (red symbols, panel c ), R-peak intervals are determined, QRS complexes are extracted (panel d ) and their root mean square amplitude (RMS) values are calculated (panel e ), a power spectrum is generated for a moving window of 16 QRS RMS values incremented one value at a time (panel f ), and its peak frequency and the R-peak interval data within the window are used to calculate the respiratory rate (RR) using the equation shown.

    Article Snippet: Single-lead body surface ECG signals were obtained during the procedure and 90 min after coil placement using the AD Instruments PowerLab 4/35 system with Labchart 8 software.

    Techniques: Blocking Assay, Generated