Review



ix83 yokogawa spinning disc confocal microscope  (Yokogawa Electric)


Bioz Verified Symbol Yokogawa Electric is a verified supplier
Bioz Manufacturer Symbol Yokogawa Electric manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Yokogawa Electric ix83 yokogawa spinning disc confocal microscope
    Ix83 Yokogawa Spinning Disc Confocal Microscope, supplied by Yokogawa Electric, used in various techniques. Bioz Stars score: 99/100, based on 7168 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/CSU-X1/pm41594613-53-6-7
    Average 99 stars, based on 7168 article reviews
    ix83 yokogawa spinning disc confocal microscope - by Bioz Stars, 2026-10
    99/100 stars

    Images

    Related Articles

    Microscopy:

    Article Title: Taxane-induced conformational changes in the microtubule lattice activate GEF-H1-dependent RhoA signalling.
    Article Snippet: Cells were imaged either on a custom Yokogawa spinning disc or an Andor Dragonfly spinning disc. .. The Yokogawa spinning disc microscope had an Eclipse Ti-E body (Nikon) with perfect focus, a MS-2000-XYZ stage with Piexo Top Plate (ASI), a CSU-X1-A1 spinning disc unit (Yokogawa) and STXG-PLAMX-SETZ21L temperature and CO2 control (TokaiHit). .. An S Fluor ×100 oil objective (Nikon) was used to acquire images.

    Article Title: Structural mechanism of Gasdermin E-mediated mtDNA release from apoptotic mitochondria
    Article Snippet: .. Cells were imaged before apoptosis induction and every 30 min after induction using 1 μM ABT-737 and 1 μM S63845 with a fully motorized inverted spinning disc microscope based on a Zeiss Cell Observer.Z1 and a CSU-X1 spinning disc unit (Yokogawa) with a 63x, oil immersion objective (Alpha Plan-Apochromat, NA 1.46). ..

    Article Title: Endogenous Expression of the Class I Phosphatidylinositol Transfer Protein PPIT-2 in Caenorhabditis elegans
    Article Snippet: .. Microscopy All fluorescence imaging was performed using a spinning-disk confocal system equipped with a Nikon 60× 1.2 NA water-immersion objective, a Hamamatsu C15440 ORCA-Fusion BT Digital camera, and a Yokogawa CSU-X1 confocal scanner unit. .. Imaging acquisition was controlled by Nikon's NIS-Element software (Version 6.10).

    Article Title: Tall adhesions overcome cell surface steric interference and rescue antibody-dependent phagocytosis in macrophages
    Article Snippet: .. Imaging and measurement of enrichment index at GUV-GUV interface The formed GUV-GUV pairs are then imaged in their equatorial plane on a Nikon Ti-2 microscope equipped with a spinning-disk unit (Yokogawa CSU-X1) through an SR plan Apo IR 60X/1.27 WI objective. ..

    Article Title: cGMP Signaling in Arterioles Revealed by FRET-Based Real-Time Measurement in Mice In Vivo.
    Article Snippet: .. It comprised an upright microscope (Axio Examiner Z1, Zeiss), a Yokogawa CSU- X1 spinning disk confocal scanner, a DualView beam splitter with appropriate filters, and EM- CCD cameras (QuantEM 512, Photometrics) to record images of CFP and YFP emission simultaneously. .. A pE- 2 LED system (CoolLED) was used for epifluorescence illumination.

    Mass Spectrometry:

    Article Title: Taxane-induced conformational changes in the microtubule lattice activate GEF-H1-dependent RhoA signalling.
    Article Snippet: Cells were imaged either on a custom Yokogawa spinning disc or an Andor Dragonfly spinning disc. .. The Yokogawa spinning disc microscope had an Eclipse Ti-E body (Nikon) with perfect focus, a MS-2000-XYZ stage with Piexo Top Plate (ASI), a CSU-X1-A1 spinning disc unit (Yokogawa) and STXG-PLAMX-SETZ21L temperature and CO2 control (TokaiHit). .. An S Fluor ×100 oil objective (Nikon) was used to acquire images.

    Control:

    Article Title: Taxane-induced conformational changes in the microtubule lattice activate GEF-H1-dependent RhoA signalling.
    Article Snippet: Cells were imaged either on a custom Yokogawa spinning disc or an Andor Dragonfly spinning disc. .. The Yokogawa spinning disc microscope had an Eclipse Ti-E body (Nikon) with perfect focus, a MS-2000-XYZ stage with Piexo Top Plate (ASI), a CSU-X1-A1 spinning disc unit (Yokogawa) and STXG-PLAMX-SETZ21L temperature and CO2 control (TokaiHit). .. An S Fluor ×100 oil objective (Nikon) was used to acquire images.

    Fluorescence:

    Article Title: Distinct Regulatory Logic Controls Recruitment and Membrane Dynamics of ESCRT-III Subunit Vps60
    Article Snippet: Endosomal Sorting Complexes Required for Transport (ESCRT) machinery drives membrane remodeling and scission events essential for multivesicular body (MVB) biogenesis.. The accessory ESCRT-III subunit Vps60 (mammalian CHMP5) shares structural features with the major polymerizing subunit Snf7, including the capacity to form homopolymers in vitro.. Here, we demonstrate in Saccharomyces cerevisiae that Vps60 recruitment and polymerization require conditions that permit Snf7 polymer turnover: Vps60 is largely excluded when Snf7 assembly is absent and when Snf7 disassembly is blocked, consistent with recruitment of Vps60 late in the ESCRT-III cycle to Snf7 assemblies that undergo normal turnover.

    Article Title: Endogenous Expression of the Class I Phosphatidylinositol Transfer Protein PPIT-2 in Caenorhabditis elegans
    Article Snippet: .. Microscopy All fluorescence imaging was performed using a spinning-disk confocal system equipped with a Nikon 60× 1.2 NA water-immersion objective, a Hamamatsu C15440 ORCA-Fusion BT Digital camera, and a Yokogawa CSU-X1 confocal scanner unit. .. Imaging acquisition was controlled by Nikon's NIS-Element software (Version 6.10).

    Inverted Microscopy:

    Article Title: Distinct Regulatory Logic Controls Recruitment and Membrane Dynamics of ESCRT-III Subunit Vps60
    Article Snippet: Endosomal Sorting Complexes Required for Transport (ESCRT) machinery drives membrane remodeling and scission events essential for multivesicular body (MVB) biogenesis.. The accessory ESCRT-III subunit Vps60 (mammalian CHMP5) shares structural features with the major polymerizing subunit Snf7, including the capacity to form homopolymers in vitro.. Here, we demonstrate in Saccharomyces cerevisiae that Vps60 recruitment and polymerization require conditions that permit Snf7 polymer turnover: Vps60 is largely excluded when Snf7 assembly is absent and when Snf7 disassembly is blocked, consistent with recruitment of Vps60 late in the ESCRT-III cycle to Snf7 assemblies that undergo normal turnover.

    Spinning Disk:

    Article Title: Distinct Regulatory Logic Controls Recruitment and Membrane Dynamics of ESCRT-III Subunit Vps60
    Article Snippet: Endosomal Sorting Complexes Required for Transport (ESCRT) machinery drives membrane remodeling and scission events essential for multivesicular body (MVB) biogenesis.. The accessory ESCRT-III subunit Vps60 (mammalian CHMP5) shares structural features with the major polymerizing subunit Snf7, including the capacity to form homopolymers in vitro.. Here, we demonstrate in Saccharomyces cerevisiae that Vps60 recruitment and polymerization require conditions that permit Snf7 polymer turnover: Vps60 is largely excluded when Snf7 assembly is absent and when Snf7 disassembly is blocked, consistent with recruitment of Vps60 late in the ESCRT-III cycle to Snf7 assemblies that undergo normal turnover.

    Article Title: Drosophila Orb2 contributes to neural stem cell centrosome asymmetry and cell growth
    Article Snippet: The deregulation of neural stem cell (NSC) homeostasis underlies neurodevelopmental disorders and tumorigenesis.. In the Drosophila larval brain, NSCs divide asymmetrically along an invariant apical-basal axis to yield a larger self-renewing stem cell and a smaller, differentiating sibling.. NSC divisions are instructed by centrosomes, which recruit pericentriolar material (PCM) important for microtubule-organizing activity.

    Article Title: Endogenous Expression of the Class I Phosphatidylinositol Transfer Protein PPIT-2 in Caenorhabditis elegans
    Article Snippet: .. Microscopy All fluorescence imaging was performed using a spinning-disk confocal system equipped with a Nikon 60× 1.2 NA water-immersion objective, a Hamamatsu C15440 ORCA-Fusion BT Digital camera, and a Yokogawa CSU-X1 confocal scanner unit. .. Imaging acquisition was controlled by Nikon's NIS-Element software (Version 6.10).

    Article Title: Tall adhesions overcome cell surface steric interference and rescue antibody-dependent phagocytosis in macrophages
    Article Snippet: .. Imaging and measurement of enrichment index at GUV-GUV interface The formed GUV-GUV pairs are then imaged in their equatorial plane on a Nikon Ti-2 microscope equipped with a spinning-disk unit (Yokogawa CSU-X1) through an SR plan Apo IR 60X/1.27 WI objective. ..

    Article Title: cGMP Signaling in Arterioles Revealed by FRET-Based Real-Time Measurement in Mice In Vivo.
    Article Snippet: .. It comprised an upright microscope (Axio Examiner Z1, Zeiss), a Yokogawa CSU- X1 spinning disk confocal scanner, a DualView beam splitter with appropriate filters, and EM- CCD cameras (QuantEM 512, Photometrics) to record images of CFP and YFP emission simultaneously. .. A pE- 2 LED system (CoolLED) was used for epifluorescence illumination.

    Confocal:

    Article Title: Distinct Regulatory Logic Controls Recruitment and Membrane Dynamics of ESCRT-III Subunit Vps60
    Article Snippet: Endosomal Sorting Complexes Required for Transport (ESCRT) machinery drives membrane remodeling and scission events essential for multivesicular body (MVB) biogenesis.. The accessory ESCRT-III subunit Vps60 (mammalian CHMP5) shares structural features with the major polymerizing subunit Snf7, including the capacity to form homopolymers in vitro.. Here, we demonstrate in Saccharomyces cerevisiae that Vps60 recruitment and polymerization require conditions that permit Snf7 polymer turnover: Vps60 is largely excluded when Snf7 assembly is absent and when Snf7 disassembly is blocked, consistent with recruitment of Vps60 late in the ESCRT-III cycle to Snf7 assemblies that undergo normal turnover.

    Article Title: Endogenous Expression of the Class I Phosphatidylinositol Transfer Protein PPIT-2 in Caenorhabditis elegans
    Article Snippet: .. Microscopy All fluorescence imaging was performed using a spinning-disk confocal system equipped with a Nikon 60× 1.2 NA water-immersion objective, a Hamamatsu C15440 ORCA-Fusion BT Digital camera, and a Yokogawa CSU-X1 confocal scanner unit. .. Imaging acquisition was controlled by Nikon's NIS-Element software (Version 6.10).

    Article Title: VvDLK negatively regulates cold tolerance by interacting with Vv14-3-3A in grapevine.
    Article Snippet: .. Confocal images 1 were recorded with an AxioObserver Z1 (Zeiss, Jena, Germany) using a 63 × LCI -NeofluarImmCorr DIC 2 objective (NA 1.3) and a spinning-disc device (YOKOGAWA CSU-X1 5000). ..

    Article Title: cGMP Signaling in Arterioles Revealed by FRET-Based Real-Time Measurement in Mice In Vivo.
    Article Snippet: .. It comprised an upright microscope (Axio Examiner Z1, Zeiss), a Yokogawa CSU- X1 spinning disk confocal scanner, a DualView beam splitter with appropriate filters, and EM- CCD cameras (QuantEM 512, Photometrics) to record images of CFP and YFP emission simultaneously. .. A pE- 2 LED system (CoolLED) was used for epifluorescence illumination.

    Imaging:

    Article Title: Endogenous Expression of the Class I Phosphatidylinositol Transfer Protein PPIT-2 in Caenorhabditis elegans
    Article Snippet: .. Microscopy All fluorescence imaging was performed using a spinning-disk confocal system equipped with a Nikon 60× 1.2 NA water-immersion objective, a Hamamatsu C15440 ORCA-Fusion BT Digital camera, and a Yokogawa CSU-X1 confocal scanner unit. .. Imaging acquisition was controlled by Nikon's NIS-Element software (Version 6.10).

    Article Title: Tall adhesions overcome cell surface steric interference and rescue antibody-dependent phagocytosis in macrophages
    Article Snippet: .. Imaging and measurement of enrichment index at GUV-GUV interface The formed GUV-GUV pairs are then imaged in their equatorial plane on a Nikon Ti-2 microscope equipped with a spinning-disk unit (Yokogawa CSU-X1) through an SR plan Apo IR 60X/1.27 WI objective. ..

    Electron Microscopy:

    Article Title: cGMP Signaling in Arterioles Revealed by FRET-Based Real-Time Measurement in Mice In Vivo.
    Article Snippet: .. It comprised an upright microscope (Axio Examiner Z1, Zeiss), a Yokogawa CSU- X1 spinning disk confocal scanner, a DualView beam splitter with appropriate filters, and EM- CCD cameras (QuantEM 512, Photometrics) to record images of CFP and YFP emission simultaneously. .. A pE- 2 LED system (CoolLED) was used for epifluorescence illumination.



    Similar Products

    99
    Olympus inverted fluorescence microscope
    Inverted Fluorescence Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42893963-61-24-27
    Average 99 stars, based on 1 article reviews
    inverted fluorescence microscope - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    Olympus olympus ix83 microscope
    Olympus Ix83 Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42883941-261-6-6
    Average 99 stars, based on 1 article reviews
    olympus ix83 microscope - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    Olympus olympus ix83 laser
    Olympus Ix83 Laser, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42875585-415-21-21
    Average 99 stars, based on 1 article reviews
    olympus ix83 laser - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    Olympus inverted microscope
    Inverted Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42880283-378-11-13
    Average 99 stars, based on 1 article reviews
    inverted microscope - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    Olympus ixplore inverted microscope system
    Ixplore Inverted Microscope System, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42874881-100-12-11
    Average 99 stars, based on 1 article reviews
    ixplore inverted microscope system - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    Olympus evident olympus ix83 microscope
    Evident Olympus Ix83 Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42873286-272-16-16
    Average 99 stars, based on 1 article reviews
    evident olympus ix83 microscope - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    99
    Olympus olympus ix83 body
    Olympus Ix83 Body, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ix83+microscope/IX83+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/pm42867995-749-23-23
    Average 99 stars, based on 1 article reviews
    olympus ix83 body - by Bioz Stars, 2026-10
    99/100 stars
      Buy from Supplier

    Image Search Results