Journal: Advanced Science
Article Title: Human Engineered Heart Tissues Reproduce Trigger‐ and Substrate‐Driven Mechanisms of Ventricular Tachycardia
doi: 10.1002/advs.78429
Figure Lengend Snippet: aLQTS condition prolongs APD 80 , increases dispersion, and promotes wavebreak, reentry, and a VT‐like phenotype in EHTs. Multiple dual voltage and Ca 2+ optical mapping recordings were obtained per condition. Fraction of recording time spent above 120 (A) and 140 (B) bpm for EHTs paced at 1.0 Hz. Five EHTs from iPSC line 1 were paced at 1.5 Hz; these recordings were pooled with the 1.0 Hz data because the results were comparable. Shapiro‐Wilk indicated non‐normality for several distributions; unpaired two‐sided Mann‐Whitney U tests were applied (CTL N = 27, aLQTS = 28, from 4 batches for iPSC 1 and 2 batches for iPSC2s). Box‐and‐whisker plots show median and interquartile range; dots are individual EHTs. C. Voltage (left) and Ca 2+ (right) kymographs from a CTL (top) and aLQTS (bottom) recording showing simultaneous activation under pacing in the CTL and progressive loss of capture, beat acceleration, and slowed CV under aLQTS (Video and ). D‐F. Heatmaps showing pixel‐wise changes across beats for APD 80 , DI, and dV/dt from a representative EHT under CTL (left) and aLQTS (right) conditions. APD 80 becomes prolonged and spatiotemporal localized heterogeneity increases under aLQTS condition, while DI shortens and dV/dt slows, likewise becoming more heterogeneous. G. Dominant frequency (DF) maps from beats 22–28 outlined in green highlight regions of increased frequency leading to wavebreak and reentry across the EHT. H. ROI‐based voltage and Ca 2+ traces transition from slow but continuous propagation to slowed conduction causing conduction block and reentry before returning to slow but continuous propagation. Activation, APD 80 , and dV/dt maps for beats 22 (I) and 24 (J) show decreased CV and increased spatiotemporal APD 80 heterogeneity, producing dV/dt minima and conduction delays preceding wavebreak. K. Diagrams (top), voltage fluorescence (middle), and phase (bottom) maps for beats 25–27. Signals emerge from the left head, move in a downward circular motion (a‐b), slow down within the head‐neck space (b‐c), and bifurcate onto areas that exhibited low APD (prior beat, J), while avoiding high‐APD areas. Two PS/rotor arise: one moving leftward, initiating a second rotation in the left head (c‐d1), and the other propagating on the upper side towards the right head (c‐d2). After rotation, the left wave (d1‐e1) collided with a bidirectional wave initiated near the right neck (from d2), and both wavefronts extinguished shortly after. These events lead to the restoration of continuous but slow propagation by beat 28 (L), the dissipation of APD gradients, and the normalization of dV/dt (K). iPSC line 1, Gibco Episomal iPSC Line; A18945; iPSC line 2, Axol differentiated cardiomyocytes, hiPSC‐CMs; AXCC‐VC01.
Article Snippet: We used Axol hiPSC‐CMs (Axol, ax2508) as iPSC line 2 and expanded them as described above.
Techniques: Dispersion, MANN-WHITNEY, Whisker Assay, Activation Assay, Blocking Assay, Fluorescence, IPSC