Review



total internal reflection fluorescence tirf microscope  (Nikon)


Bioz Verified Symbol Nikon is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Nikon total internal reflection fluorescence tirf microscope
    Total Internal Reflection Fluorescence Tirf Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 65334 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/Objectives/pm41373795-214-6-12
    Average 99 stars, based on 65334 article reviews
    total internal reflection fluorescence tirf microscope - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    Imaging:

    Article Title: Transcriptional repression of central spindle genes marks the transition to endomitosis in the C. elegans intestine
    Article Snippet: .. Time-lapse live imaging was performed on a Nikon Ti2 microscope equipped with NIS-elements software (Nikon), an L6Cc illumination unit (Oxxius), a CSU-X1 spinning disk scanner unit (Yokogawa), and a C11440-22C camera (Hamamatsu), using a Plan Apo 100× oil objective (NA 1.45, Nikon) and 2× binning. ..

    Article Title: Bio‑Inspired Heterotypic Polymers Enable Independent Control of Distinct Coacervate Mesoscale Properties
    Article Snippet: .. The wells were covered with aluminum tapes, and the samples were incubated for 24 h at ambient temperature before imaging via an epi ‐fluorescence microscope (Eclipse Ti‐E, Nikon) using a 60× oil objective (CFI Plan Apo Lambda, Nikon). ..

    Article Title: WDR76 Drives Hepatocellular Carcinoma Stemness and Progression by Stabilizing CBX5 and Promoting Phase Separation‐Dependent Chromatin Remodeling
    Article Snippet: For in vitro experiments such as FRAP and time‐lapse imaging experiments, phase separation was recorded on 384 low‐binding multi‐well 0.17 mm microscopy plates (Cellvis). .. Imaging was performed with a NIKON A1 microscope equipped with a 60× or 100× oil immersion objective. ..

    Microscopy:

    Article Title: Transcriptional repression of central spindle genes marks the transition to endomitosis in the C. elegans intestine
    Article Snippet: .. Time-lapse live imaging was performed on a Nikon Ti2 microscope equipped with NIS-elements software (Nikon), an L6Cc illumination unit (Oxxius), a CSU-X1 spinning disk scanner unit (Yokogawa), and a C11440-22C camera (Hamamatsu), using a Plan Apo 100× oil objective (NA 1.45, Nikon) and 2× binning. ..

    Article Title: CRH‐CRHR1 Signaling in BNST‐vHPC Projections Mediates Trigeminal Neuropathic Pain‐Induced Anxiety‐ and Depression‐Like Behaviors
    Article Snippet: .. Stained sections were then imaged using a Nikon confocal microscope with a 40× objective (AX; Nikon, Japan). ..

    Article Title: Bio‑Inspired Heterotypic Polymers Enable Independent Control of Distinct Coacervate Mesoscale Properties
    Article Snippet: .. The wells were covered with aluminum tapes, and the samples were incubated for 24 h at ambient temperature before imaging via an epi ‐fluorescence microscope (Eclipse Ti‐E, Nikon) using a 60× oil objective (CFI Plan Apo Lambda, Nikon). ..

    Article Title: An LHX2-DACH1 regulatory innovation drives basal progenitor expansion in the primate neocortex
    Article Snippet: Briefly, 100-μm cortical slices were embedded in Cellmatrix Type I-A following the manufacturer’s protocol on the cell culture insert (Merck) in a glass-bottom dish with Neurobasal medium with B27 supplement. .. The time-lapse images were acquired under 16× objective lens (numerical aperture, 0.8; Nikon) using a two-photon microscope (A1R MP+, Nikon) with a custom-made two-photon fiber laser source (Seven Six Co. Ltd.) for 48 hours under 40% O 2 and 5% CO 2 conditions. .. The morphology and behavior of Achilles + mKate2 + RG cells were traced and analyzed using the built-in ImageJ packages.

    Article Title: WDR76 Drives Hepatocellular Carcinoma Stemness and Progression by Stabilizing CBX5 and Promoting Phase Separation‐Dependent Chromatin Remodeling
    Article Snippet: For in vitro experiments such as FRAP and time‐lapse imaging experiments, phase separation was recorded on 384 low‐binding multi‐well 0.17 mm microscopy plates (Cellvis). .. Imaging was performed with a NIKON A1 microscope equipped with a 60× or 100× oil immersion objective. ..

    Article Title: A neural circuit mediating altitude control in Drosophila
    Article Snippet: .. For optogenetic silencing, flies received a 1 s, 530 nm light pulse (1.021 mW mm −2 ) confined to 0.9 mm spot on the back of the fly’s head through a 10x microscope objective (Nikon). ..

    Article Title: A mutation in the conserved NPxY motif of β integrin PAT-3 alters outgrowth of neuronal dendritic spines.
    Article Snippet: .. Images in Panel E were obtained on a Yokogawa CSU-Z1 spinning disk confocal mounted on a Nikon NiE upright motorized microscope equipped with a Nikon 60x oil immersion objective and a Prime BSI Express CMOS camera (Teledyne Vision Solutions). .. Z stack images were acquired using Nikon Elements software, using identical imaging and laser settings.

    Software:

    Article Title: Transcriptional repression of central spindle genes marks the transition to endomitosis in the C. elegans intestine
    Article Snippet: .. Time-lapse live imaging was performed on a Nikon Ti2 microscope equipped with NIS-elements software (Nikon), an L6Cc illumination unit (Oxxius), a CSU-X1 spinning disk scanner unit (Yokogawa), and a C11440-22C camera (Hamamatsu), using a Plan Apo 100× oil objective (NA 1.45, Nikon) and 2× binning. ..

    Spinning Disk:

    Article Title: Transcriptional repression of central spindle genes marks the transition to endomitosis in the C. elegans intestine
    Article Snippet: .. Time-lapse live imaging was performed on a Nikon Ti2 microscope equipped with NIS-elements software (Nikon), an L6Cc illumination unit (Oxxius), a CSU-X1 spinning disk scanner unit (Yokogawa), and a C11440-22C camera (Hamamatsu), using a Plan Apo 100× oil objective (NA 1.45, Nikon) and 2× binning. ..

    Article Title: A mutation in the conserved NPxY motif of β integrin PAT-3 alters outgrowth of neuronal dendritic spines.
    Article Snippet: .. Images in Panel E were obtained on a Yokogawa CSU-Z1 spinning disk confocal mounted on a Nikon NiE upright motorized microscope equipped with a Nikon 60x oil immersion objective and a Prime BSI Express CMOS camera (Teledyne Vision Solutions). .. Z stack images were acquired using Nikon Elements software, using identical imaging and laser settings.

    Staining:

    Article Title: CRH‐CRHR1 Signaling in BNST‐vHPC Projections Mediates Trigeminal Neuropathic Pain‐Induced Anxiety‐ and Depression‐Like Behaviors
    Article Snippet: .. Stained sections were then imaged using a Nikon confocal microscope with a 40× objective (AX; Nikon, Japan). ..

    Confocal:

    Article Title: CRH‐CRHR1 Signaling in BNST‐vHPC Projections Mediates Trigeminal Neuropathic Pain‐Induced Anxiety‐ and Depression‐Like Behaviors
    Article Snippet: .. Stained sections were then imaged using a Nikon confocal microscope with a 40× objective (AX; Nikon, Japan). ..

    Article Title: A mutation in the conserved NPxY motif of β integrin PAT-3 alters outgrowth of neuronal dendritic spines.
    Article Snippet: .. Images in Panel E were obtained on a Yokogawa CSU-Z1 spinning disk confocal mounted on a Nikon NiE upright motorized microscope equipped with a Nikon 60x oil immersion objective and a Prime BSI Express CMOS camera (Teledyne Vision Solutions). .. Z stack images were acquired using Nikon Elements software, using identical imaging and laser settings.

    Incubation:

    Article Title: Bio‑Inspired Heterotypic Polymers Enable Independent Control of Distinct Coacervate Mesoscale Properties
    Article Snippet: .. The wells were covered with aluminum tapes, and the samples were incubated for 24 h at ambient temperature before imaging via an epi ‐fluorescence microscope (Eclipse Ti‐E, Nikon) using a 60× oil objective (CFI Plan Apo Lambda, Nikon). ..

    Fluorescence:

    Article Title: Bio‑Inspired Heterotypic Polymers Enable Independent Control of Distinct Coacervate Mesoscale Properties
    Article Snippet: .. The wells were covered with aluminum tapes, and the samples were incubated for 24 h at ambient temperature before imaging via an epi ‐fluorescence microscope (Eclipse Ti‐E, Nikon) using a 60× oil objective (CFI Plan Apo Lambda, Nikon). ..

    other:

    Article Title: Periprostatic Adipose Tissue Promotes Prostate Cancer Progression through Androgen Receptor‐Mediated Lipolysis
    Article Snippet: At 36 h after transduction, FRET imaging was performed using a 20× objective on a Nikon Ti‐E2 microscope.



    Similar Products

    97
    Olympus prismbased total internal reflection fluorescence microscope ix73
    Prismbased Total Internal Reflection Fluorescence Microscope Ix73, supplied by Olympus, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/IX73+Inverted+Microscope+Currently+integrated+into+IXplore+Systems/10__1021_slash_acs__analchem__6c03504-59-8-16
    Average 97 stars, based on 1 article reviews
    prismbased total internal reflection fluorescence microscope ix73 - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    99
    Nikon ti2 e total internal reflection fluorescence microscope
    Ti2 E Total Internal Reflection Fluorescence Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/Objectives/pm40880498-217-10-9
    Average 99 stars, based on 1 article reviews
    ti2 e total internal reflection fluorescence microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Nikon custom total internal reflection fluorescence tirf microscope
    Custom Total Internal Reflection Fluorescence Tirf Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/Objectives/bio_rxiv__64898__2026__01__23__700875-252-23-30
    Average 99 stars, based on 1 article reviews
    custom total internal reflection fluorescence tirf microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Nikon total internal reflection fluorescence tirf microscope
    Total Internal Reflection Fluorescence Tirf Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/Objectives/bio_rxiv__64898__2026__01__22__700042____media___1-51-8-14
    Average 99 stars, based on 1 article reviews
    total internal reflection fluorescence tirf microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Nikon internal reflection fluorescence tirf microscope
    Internal Reflection Fluorescence Tirf Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/Objectives/pmc12830645-283-9-14
    Average 99 stars, based on 1 article reviews
    internal reflection fluorescence tirf microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Nikon internal reflection fluorescence microscope
    DNA-PAINT experiment on single gold nanospheres. (a) Schematic of a gold nanosphere sample on a glass substrate excited with an epi-illumination <t>fluorescence</t> <t>microscope.</t> Fluorescent intensity time traces are recorded at 10 frames per second, showing bursts with an event typically lasting for 10 frames. Each fluorescent event, averaged over all frames above the threshold, provides a polarized PSF image. Four example events with the extracted α and DoLP indicate single-emitter binding to a particle at different locations. Scale bar of 200 nm applies to all PSFs. (b) Scatter plot of DoLP and α apparent for fluorescence events on six single nanospheres. (c) DoLP as a function of integrated fluorescence intensity showing that brighter events exhibit a higher DoLP because they occur at the equator of the particle.
    Internal Reflection Fluorescence Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/Objectives/pmc12717926-210-8-12
    Average 99 stars, based on 1 article reviews
    internal reflection fluorescence microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Nikon eclipse ti2 total internal reflection fluorescence tirf microscope
    a Time-lapse <t>TIRF</t> microscopy images of debranching events in the absence (left) or presence (right) of Coro7 FL. The flow rate is 200 µL min − 1 , corresponding to an average force of ~0.45 pN on an average ~2 µm-long branch . b Time courses of branch dissociation in the absence or presence of Coro7 FL. Solid lines through the data represent best fits to single (without Coro7 FL, black) or double (with Coro7 FL, blue shades) exponentials. c Debranching rate constants as a function of Coro7 FL concentration. The individual data points represent the observed debranching rate constants obtained from the best fits of the time courses shown in ( b ) to double exponentials. The teal and cyan horizontal lines represent the best global fits of the debranching time courses shown in ( b ) to a double exponential with a single rate constant for each phase (fast and slow). d Dependence of the fast-debranching phase amplitudes on Coro7 FL concentration. The blue circles represent the amplitudes obtained from individual fitting of the time courses shown in ( b ) to double exponentials, and the red circles represent the relative amplitudes obtained from global fitting. The solid line through the data represents the best fit to a rectangular hyperbola, yielding an apparent Coro7 FL binding affinity of 31 ± 1 nM for both individually and globally fitted parameters. e – g Time courses of branch dissociation in the absence or presence of various concentrations of Coro7 construct β2CA (solid lines indicate double-exponential fits) and constructs β1β2 and CA (solid lines indicate single-exponential fits). The graphs in ( b , e – g ) show averages; each condition was repeated two to four times, with an average of 43 fields of view, 113 mother filaments, and 155 branches analyzed per condition. In ( c and d ), the error bars represent standard deviation (SD) of the best-fit parameters from the time courses shown in ( b ), as calculated using Origin software. Source data are provided in the Source Data file.
    Eclipse Ti2 Total Internal Reflection Fluorescence Tirf Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/internal+reflection+fluorescence+microscope/ECLIPSE+Ti2/pmc12592476-321-12-11
    Average 99 stars, based on 1 article reviews
    eclipse ti2 total internal reflection fluorescence tirf microscope - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    Image Search Results


    DNA-PAINT experiment on single gold nanospheres. (a) Schematic of a gold nanosphere sample on a glass substrate excited with an epi-illumination fluorescence microscope. Fluorescent intensity time traces are recorded at 10 frames per second, showing bursts with an event typically lasting for 10 frames. Each fluorescent event, averaged over all frames above the threshold, provides a polarized PSF image. Four example events with the extracted α and DoLP indicate single-emitter binding to a particle at different locations. Scale bar of 200 nm applies to all PSFs. (b) Scatter plot of DoLP and α apparent for fluorescence events on six single nanospheres. (c) DoLP as a function of integrated fluorescence intensity showing that brighter events exhibit a higher DoLP because they occur at the equator of the particle.

    Journal: Nanophotonics

    Article Title: Single-shot Stokes polarimetry of plasmon-coupled single-molecule fluorescence

    doi: 10.1515/nanoph-2025-0352

    Figure Lengend Snippet: DNA-PAINT experiment on single gold nanospheres. (a) Schematic of a gold nanosphere sample on a glass substrate excited with an epi-illumination fluorescence microscope. Fluorescent intensity time traces are recorded at 10 frames per second, showing bursts with an event typically lasting for 10 frames. Each fluorescent event, averaged over all frames above the threshold, provides a polarized PSF image. Four example events with the extracted α and DoLP indicate single-emitter binding to a particle at different locations. Scale bar of 200 nm applies to all PSFs. (b) Scatter plot of DoLP and α apparent for fluorescence events on six single nanospheres. (c) DoLP as a function of integrated fluorescence intensity showing that brighter events exhibit a higher DoLP because they occur at the equator of the particle.

    Article Snippet: DNA-PAINT measurements were performed on an inverted total internal reflection fluorescence microscope (Nikon) with a 100×/NA 1.49 objective.

    Techniques: Fluorescence, Microscopy, Binding Assay

    a Time-lapse TIRF microscopy images of debranching events in the absence (left) or presence (right) of Coro7 FL. The flow rate is 200 µL min − 1 , corresponding to an average force of ~0.45 pN on an average ~2 µm-long branch . b Time courses of branch dissociation in the absence or presence of Coro7 FL. Solid lines through the data represent best fits to single (without Coro7 FL, black) or double (with Coro7 FL, blue shades) exponentials. c Debranching rate constants as a function of Coro7 FL concentration. The individual data points represent the observed debranching rate constants obtained from the best fits of the time courses shown in ( b ) to double exponentials. The teal and cyan horizontal lines represent the best global fits of the debranching time courses shown in ( b ) to a double exponential with a single rate constant for each phase (fast and slow). d Dependence of the fast-debranching phase amplitudes on Coro7 FL concentration. The blue circles represent the amplitudes obtained from individual fitting of the time courses shown in ( b ) to double exponentials, and the red circles represent the relative amplitudes obtained from global fitting. The solid line through the data represents the best fit to a rectangular hyperbola, yielding an apparent Coro7 FL binding affinity of 31 ± 1 nM for both individually and globally fitted parameters. e – g Time courses of branch dissociation in the absence or presence of various concentrations of Coro7 construct β2CA (solid lines indicate double-exponential fits) and constructs β1β2 and CA (solid lines indicate single-exponential fits). The graphs in ( b , e – g ) show averages; each condition was repeated two to four times, with an average of 43 fields of view, 113 mother filaments, and 155 branches analyzed per condition. In ( c and d ), the error bars represent standard deviation (SD) of the best-fit parameters from the time courses shown in ( b ), as calculated using Origin software. Source data are provided in the Source Data file.

    Journal: Nature Communications

    Article Title: Mechanism of Arp2/3 complex branch disassembly by human Coro7

    doi: 10.1038/s41467-025-64787-z

    Figure Lengend Snippet: a Time-lapse TIRF microscopy images of debranching events in the absence (left) or presence (right) of Coro7 FL. The flow rate is 200 µL min − 1 , corresponding to an average force of ~0.45 pN on an average ~2 µm-long branch . b Time courses of branch dissociation in the absence or presence of Coro7 FL. Solid lines through the data represent best fits to single (without Coro7 FL, black) or double (with Coro7 FL, blue shades) exponentials. c Debranching rate constants as a function of Coro7 FL concentration. The individual data points represent the observed debranching rate constants obtained from the best fits of the time courses shown in ( b ) to double exponentials. The teal and cyan horizontal lines represent the best global fits of the debranching time courses shown in ( b ) to a double exponential with a single rate constant for each phase (fast and slow). d Dependence of the fast-debranching phase amplitudes on Coro7 FL concentration. The blue circles represent the amplitudes obtained from individual fitting of the time courses shown in ( b ) to double exponentials, and the red circles represent the relative amplitudes obtained from global fitting. The solid line through the data represents the best fit to a rectangular hyperbola, yielding an apparent Coro7 FL binding affinity of 31 ± 1 nM for both individually and globally fitted parameters. e – g Time courses of branch dissociation in the absence or presence of various concentrations of Coro7 construct β2CA (solid lines indicate double-exponential fits) and constructs β1β2 and CA (solid lines indicate single-exponential fits). The graphs in ( b , e – g ) show averages; each condition was repeated two to four times, with an average of 43 fields of view, 113 mother filaments, and 155 branches analyzed per condition. In ( c and d ), the error bars represent standard deviation (SD) of the best-fit parameters from the time courses shown in ( b ), as calculated using Origin software. Source data are provided in the Source Data file.

    Article Snippet: Direct visualization of actin filaments and branches was performed using a Nikon Eclipse Ti2 total internal reflection fluorescence (TIRF) microscope equipped with an SR HP Apo TIRF ×100 objective (Nikon) and an Andor iXon897 EMCCD camera.

    Techniques: Microscopy, Concentration Assay, Binding Assay, Construct, Standard Deviation, Software