Review



liquid-nitrogen-cooled ingaas 2d detector array camera nirvana 640ln  (Princeton Instruments)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Princeton Instruments liquid-nitrogen-cooled ingaas 2d detector array camera nirvana 640ln
    Liquid Nitrogen Cooled Ingaas 2d Detector Array Camera Nirvana 640ln, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/liquid+nitrogen+cooled+ingaas+camera+nirvana+640/pm33690965-186-10-17
    Average 90 stars, based on 1 article reviews
    liquid-nitrogen-cooled ingaas 2d detector array camera nirvana 640ln - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    Imaging:

    Article Title: Molecular-Based FRET Nanosensor with Dynamic Ratiometric NIR-IIb Fluorescence for Real-Time In Vivo Imaging and Sensing.
    Article Snippet: The excitation light was provided by 655 nm and 760 nm lasers coupled to a 450-μm core metal-cladded multimode fibre (Changchun New Industries Optoelectronics). .. The emitted light was directed from the imaging stage to the camera using a 4-inch square first surface mirror (84-448, Edmund Optics), passed through different filter sets (Thorlabs and Edmund Optics), as required by the experiments to ensure NIR-II images were taken in different subwindows, and focused onto the liquid nitrogen-cooled two-dimensional InGaAs camera (NIRvana 640LN, 640 × 512 pixels; Princeton Instruments, response 900–1600 nm) with a lens pair consisting of two achromats (200 mm and 75 mm; Thorlabs). .. An engineered diffuser (Thorlabs ED1-S20-MD) was utilized to provide uniform illumination over the working area.

    Article Title: A hybrid erbium(III)-bacteriochlorin near-infrared probe for multiplexed biomedical imaging.
    Article Snippet: 1Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials and iChem, Fudan University, Shanghai, People’s Republic of China.. 2Shanghai Key Laboratory of Functional Materials Chemistry, School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, People’s Republic of China.. 3School of Physical Science and Technology, ShanghaiTech University, Shanghai, People’s Republic of China.

    other:

    Article Title: Nerve Suture Combined With ADSCs Injection Under Real-Time and Dynamic NIR-II Fluorescence Imaging in Peripheral Nerve Regeneration in vivo
    Article Snippet: The fluorescence was then detected by a liquid-nitrogen-cooled InGaAs camera (NIRvana 640, Teledyne Princeton Instruments).

    Article Title: New Products
    Article Snippet: The NIRvana: 640LN is fully compatible with Princeton Instruments’ LightField 64-bit application software, an optional package that provides complete control of camera features via a cutting-edge graphical user interface.

    Article Title: Acceptor engineering for NIR-II dyes with high photochemical and biomedical performance
    Article Snippet: The NIR-II fluorescence images were taken by vivo imaging system (MARS, Artemis Intelligent Imaging, Shanghai, China), which is equipped with a liquid-nitrogen-cooled InGaAs SWIR camera (NIRvana-640, Teledyne Princeton Instruments, 640 × 512 pixel), SWIR lens with 50 mm focal length (MARS-FAST, Artemis Intelligent Imaging, Shanghai, China) and shadow less illumination using an 808 nm laser (FC-W-808, Changchun New Industries Optoelectronics Technology Co., Ltd.).

    Article Title: Seeking and identifying time window of antibiotic treatment under in vivo guidance of PbS QDs clustered microspheres based NIR-II fluorescence imaging
    Article Snippet: During bacterial infection, it is crucial to duly implement antibiotic treatment at a bottleneck time window when uncontrollable bacteria invasion exacerbates the condition.. Here, we present a second near-infrared (NIR-II) fluorescence imaging strategy based on lead sulfide quantum dots clustered microspheres (PbS QDs@microspheres) to guide seeking and identifying the time window of antibiotic treatment.. Our PbS QDs@microspheres with an average size of 510 nm were prepared through cross-linking process, demonstrating nine times higher photoluminescence (PL) intensity than the original PbS QDs, along with deep optical tissue penetration in muscle and 50% fat + 50% muscle.

    Article Title: Interplay of Bright Triplet and Dark Excitons Revealed by Magneto-Photoluminescence of Individual PbS/CdS Quantum Dots.
    Article Snippet: Dr. Y. Kim, Dr. Z. Hu, Dr. A. Singh, Dr. A. Singh, Dr. V. Chandrasekaran, Dr. J.. A. Hollingsworth, Dr. H. Htoon Center for Integrated Nanotechnologies Materials Physics and Applications Division Los Alamos National Laboratory Los Alamos NM 87545, USA E-mail: htoon@lanl.gov I. D. Avdeev, Dr. M. O. Nestoklon, Prof. S. V. Goupalov Ioffe Institute St. Petersburg 194021, Russia Prof. S. V. Goupalov Department of Physics Jackson State University Jackson MS 39217, USA E-mail: serguei.goupalov@jsums.edu The ORCID identification number(s) for the author(s) of this article can be found under https://doi.org/10.1002/smll.202006977.

    Fluorescence:

    Article Title: Synchronously in vivo real‐time monitoring bacterial load and temperature with evaluating immune response to decipher bacterial infection
    Article Snippet: .. Fluorescence was detected using a liquid‐nitrogen‐cooled InGaAs camera (NIR vana 640; Teledyne Princeton Instruments, Trenton, NJ, USA) located immediately above the working stage, irradiating the subject vertically. ..



    Similar Products

    90
    Roper Scientific Inc ingaas 2d array camera
    Ingaas 2d Array Camera, supplied by Roper Scientific Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/ingaas+2d+array+camera/us11873433-157-25-23
    Average 90 stars, based on 1 article reviews
    ingaas 2d array camera - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Princeton Instruments liquid-nitrogen-cooled ingaas 2d detector array camera nirvana 640ln
    Liquid Nitrogen Cooled Ingaas 2d Detector Array Camera Nirvana 640ln, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/liquid+nitrogen+cooled+ingaas+camera+nirvana+640/pm33690965-186-10-17
    Average 90 stars, based on 1 article reviews
    liquid-nitrogen-cooled ingaas 2d detector array camera nirvana 640ln - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Photon Etc 2d ingaas array camera
    2d Ingaas Array Camera, supplied by Photon Etc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/2d+ingaas+array+detector/pm32264426-150-15-19
    Average 90 stars, based on 1 article reviews
    2d ingaas array camera - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Princeton Instruments 2d array ingaas camera
    2d Array Ingaas Camera, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/2d+ingaas+array/10__1017_slash_s1551929514001060-40-17-21
    Average 90 stars, based on 1 article reviews
    2d array ingaas camera - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Princeton Instruments liquid nitrogen-cooled camera 16-bit ingaas 2d array oma-v 2d
    Liquid Nitrogen Cooled Camera 16 Bit Ingaas 2d Array Oma V 2d, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/ccd+array/pm18237169-275-20-28
    Average 90 stars, based on 1 article reviews
    liquid nitrogen-cooled camera 16-bit ingaas 2d array oma-v 2d - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Princeton Instruments liquid nitrogen-cooled camera (16-bit ingaas 2d array, oma-v 2d
    Liquid Nitrogen Cooled Camera (16 Bit Ingaas 2d Array, Oma V 2d, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ingaas+2d+array+camera/cooled+ccd+camera/10__1021_slash_ja0777234-275-20-28
    Average 90 stars, based on 1 article reviews
    liquid nitrogen-cooled camera (16-bit ingaas 2d array, oma-v 2d - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results