Review




Structured Review

Photon Etc photon etc ima microscope
Photon Etc Ima Microscope, supplied by Photon Etc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ima+hyperspectral+microscope/hyperspectral+ima+microscope/pm41001895-176-5-5
Average 86 stars, based on 1 article reviews
photon etc ima microscope - by Bioz Stars, 2026-11
86/100 stars

Images

Related Articles

Microscopy:

Article Title: Crystal-facet-directed all-vacuum-deposited perovskite solar cells.
Article Snippet: EQE was measured using a custom system built around a Bruker Vertex 80v Fourier-transform interferometer. .. Hyperspectral microscopy was performed using a Photon etc. .. IMA-VIS inverted system with 5× (Olympus MPLFLN 5×) and 20× (Olympus LCPLFLN 20× LCD) semi-apochromat objectives.

Article Title: Enhanced charge extraction in textured perovskite-silicon tandem solar cells via molecular contact functionalization
Article Snippet: .. The reflectance and PL images of the samples were collected using a hyperspectral imaging system coupled to a microscope with 2 nm spectral resolution (Photon etc. .. Transient SPV measurements were performed in an N 2 environment using a diode-pumped tunable pulse laser (Nd:YAG, EKSPLA, NT230-100, duration time of laser pulses 2–3 ns) with a spectral cleaning unit.

Article Title: Characterization of Electronic Stress-Induced Changes in Multilayer MoS 2
Article Snippet: MoS 2 Raman spectra were taken with a Renishaw inVia confocal Raman microscope using a 532 nm laser focused through a 100X objective. .. An IMA Hyperspectral Microscope from Photon etc. was used to take photoluminescence spectra under 532 nm laser excitation. .. A Zeiss Gemini 300 Variable Pressure SEM or Zeiss LEO 1525 SEM was used for electron imaging (2 −5 keV).

Article Title: Light-Driven Intraoctahedral Halide Isomerization in Two-Dimensional Mixed Halide Perovskites
Article Snippet: .. Spectrally resolved maps were acquired using an IMA hyperspectral microscope (Photon Etc.). ..

Article Title: Light-Driven Intraoctahedral Halide Isomerization in Two-Dimensional Mixed Halide Perovskites.
Article Snippet: .. Spectrally resolved maps were acquired using an IMA hyperspectral microscope (Photon Etc.). ..

Article Title: Tuning the surface nanoroughness of the recombination junction for high-performance perovskite-silicon tandem solar cells
Article Snippet: .. The PL spectra of the samples were collected using a hyperspectral imaging system coupled to a microscope with 2 nm spectral resolution (Photon etc. ..

Imaging:

Article Title: Enhanced charge extraction in textured perovskite-silicon tandem solar cells via molecular contact functionalization
Article Snippet: .. The reflectance and PL images of the samples were collected using a hyperspectral imaging system coupled to a microscope with 2 nm spectral resolution (Photon etc. .. Transient SPV measurements were performed in an N 2 environment using a diode-pumped tunable pulse laser (Nd:YAG, EKSPLA, NT230-100, duration time of laser pulses 2–3 ns) with a spectral cleaning unit.

Article Title: Tuning the surface nanoroughness of the recombination junction for high-performance perovskite-silicon tandem solar cells
Article Snippet: .. The PL spectra of the samples were collected using a hyperspectral imaging system coupled to a microscope with 2 nm spectral resolution (Photon etc. ..

other:

Article Title: Polar solvent strategy enables scalable synthesis of perovskite nanocrystal scintillators for fast X-ray imaging.
Article Snippet: PLQY measurements were conducted using a Hamamatsu Photonics system (C9920-02G, C10027), equipped with a totalreflectance integrating sphere (Labsphere A10094, 3.3-inch, Halma company).



Similar Products

86
Photon Etc ima hyperspectral microscope
Ima Hyperspectral Microscope, supplied by Photon Etc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ima+hyperspectral+microscope/hyperspectral+ima+microscope/pmc13130964-258-1-5
Average 86 stars, based on 1 article reviews
ima hyperspectral microscope - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Photon Etc wide-field hyperspectral microscope ima vistm
a – c <t>Hyperspectral</t> images of α -CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( a ), the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 660 to 700 nm ( b ) and the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 400 to 600 nm ( c ), the scalebar is 2 μm. Spatially resolved confocal fluorescence-lifetime imaging microscopy of the heterophase film (> 600 nm) ( d ) and the heterophase film (<600 nm) ( e ), the scalebar is 2 μm. f PL lifetime of the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film. The temperature-dependent PL spectroscopy of α-CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( g ), γ / δ -CsPbI 3 film ( h ) and γ / δ -CsPb(I/Cl) 3 film ( i ). Early-time transient absorption spectra measurements of perovskite thin films (0–2 ps average) with different annealing times under 400 nm pump ( j ) and 560 nm pump ( k ). l Schematic of PL phenomena of band-to-band luminescence from γ -CsPbI 3 and STE luminescence from δ -CsPbI 3 .
Wide Field Hyperspectral Microscope Ima Vistm, supplied by Photon Etc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ima+hyperspectral+microscope/wide+field+hyperspectral+microscope+ima+vistm/pmc12003789-252-9-14
Average 90 stars, based on 1 article reviews
wide-field hyperspectral microscope ima vistm - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

86
Photon Etc ima upright hyperspectral microscope
a – c <t>Hyperspectral</t> images of α -CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( a ), the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 660 to 700 nm ( b ) and the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 400 to 600 nm ( c ), the scalebar is 2 μm. Spatially resolved confocal fluorescence-lifetime imaging microscopy of the heterophase film (> 600 nm) ( d ) and the heterophase film (<600 nm) ( e ), the scalebar is 2 μm. f PL lifetime of the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film. The temperature-dependent PL spectroscopy of α-CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( g ), γ / δ -CsPbI 3 film ( h ) and γ / δ -CsPb(I/Cl) 3 film ( i ). Early-time transient absorption spectra measurements of perovskite thin films (0–2 ps average) with different annealing times under 400 nm pump ( j ) and 560 nm pump ( k ). l Schematic of PL phenomena of band-to-band luminescence from γ -CsPbI 3 and STE luminescence from δ -CsPbI 3 .
Ima Upright Hyperspectral Microscope, supplied by Photon Etc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ima+hyperspectral+microscope/hyperspectral+ima+microscope/10__1002_slash_admi__202400823-407-5-11
Average 86 stars, based on 1 article reviews
ima upright hyperspectral microscope - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
Photon Etc hyperspectral microscope ima
a – c <t>Hyperspectral</t> images of α -CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( a ), the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 660 to 700 nm ( b ) and the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 400 to 600 nm ( c ), the scalebar is 2 μm. Spatially resolved confocal fluorescence-lifetime imaging microscopy of the heterophase film (> 600 nm) ( d ) and the heterophase film (<600 nm) ( e ), the scalebar is 2 μm. f PL lifetime of the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film. The temperature-dependent PL spectroscopy of α-CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( g ), γ / δ -CsPbI 3 film ( h ) and γ / δ -CsPb(I/Cl) 3 film ( i ). Early-time transient absorption spectra measurements of perovskite thin films (0–2 ps average) with different annealing times under 400 nm pump ( j ) and 560 nm pump ( k ). l Schematic of PL phenomena of band-to-band luminescence from γ -CsPbI 3 and STE luminescence from δ -CsPbI 3 .
Hyperspectral Microscope Ima, supplied by Photon Etc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ima+hyperspectral+microscope/ima+hyperspectral+microscope/pm37322156-297-1-4
Average 90 stars, based on 1 article reviews
hyperspectral microscope ima - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


a – c Hyperspectral images of α -CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( a ), the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 660 to 700 nm ( b ) and the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 400 to 600 nm ( c ), the scalebar is 2 μm. Spatially resolved confocal fluorescence-lifetime imaging microscopy of the heterophase film (> 600 nm) ( d ) and the heterophase film (<600 nm) ( e ), the scalebar is 2 μm. f PL lifetime of the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film. The temperature-dependent PL spectroscopy of α-CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( g ), γ / δ -CsPbI 3 film ( h ) and γ / δ -CsPb(I/Cl) 3 film ( i ). Early-time transient absorption spectra measurements of perovskite thin films (0–2 ps average) with different annealing times under 400 nm pump ( j ) and 560 nm pump ( k ). l Schematic of PL phenomena of band-to-band luminescence from γ -CsPbI 3 and STE luminescence from δ -CsPbI 3 .

Journal: Nature Communications

Article Title: Nanoscale heterophase regulation enables sunlight-like full-spectrum white electroluminescence

doi: 10.1038/s41467-025-58743-0

Figure Lengend Snippet: a – c Hyperspectral images of α -CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( a ), the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 660 to 700 nm ( b ) and the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film ranging from 400 to 600 nm ( c ), the scalebar is 2 μm. Spatially resolved confocal fluorescence-lifetime imaging microscopy of the heterophase film (> 600 nm) ( d ) and the heterophase film (<600 nm) ( e ), the scalebar is 2 μm. f PL lifetime of the γ / δ -CsPbI 3 and γ / δ -CsPb(I/Cl) 3 film. The temperature-dependent PL spectroscopy of α-CsPbI 3 and α -CsPb(I/Cl) 3 QDs film ( g ), γ / δ -CsPbI 3 film ( h ) and γ / δ -CsPb(I/Cl) 3 film ( i ). Early-time transient absorption spectra measurements of perovskite thin films (0–2 ps average) with different annealing times under 400 nm pump ( j ) and 560 nm pump ( k ). l Schematic of PL phenomena of band-to-band luminescence from γ -CsPbI 3 and STE luminescence from δ -CsPbI 3 .

Article Snippet: For hyperspectral microscopy, PL mappings were captured using a wide-field hyperspectral microscope (IMA VISTM, Photon, etc.) with a low-noise silicon CCD camera, and the samples were illuminated by a continuous-wave 405 nm laser with an excitation density of 100 mW cm −2 .

Techniques: Fluorescence, Imaging, Microscopy, Spectroscopy