Review




Structured Review

Ichor Medical ichor trigrid electrode array
Ichor Trigrid Electrode Array, supplied by Ichor Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ichor+trigrid+electrode+array/trigrid+electrode+array/pm31890729-227-16-20
Average 90 stars, based on 1 article reviews
ichor trigrid electrode array - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Injection:

Article Title: Antibodies with improved stability to intestinal digestion, polynucleotides thereof and methods of use thereof to treat disease
Article Snippet: A strong antibody response to a protein antigen can be induced by vaccination of cattle with a DNA vector containing a gene encoding the desired antigen (see, e.g., van Drunen Little-van den Hurk et al., Clin Vaccine Immunol 2013; 20:166-73). .. Individual animals are injected in the right gluteus maximus muscle with 1.5 mg of plasmid DNA in 1 mL, followed by application of a 250-V/cm electrical field for 400 ms at a 10% duty cycle, using a TriGrid electrode array (Ichor Medical Systems). ..

Article Title: Plasmid-Mediated Gene Therapy in Mouse Models of Limb Girdle Muscular Dystrophy.
Article Snippet: .. Plasmid DNAwas injected into mouse hind limbmuscles using intramuscular injection with a needle attached to the Ichor TriGrid electrode array (Ichor Medical Systems, San Diego, CA, USA). .. Briefly, mice were anesthetized with isoflurane, fur was removed, and 25 or 50 mg of plasmid DNA in 50 ml Hank’s balanced salt solution (HBSS; ThermoFisher Scientific, Waltham, MA, USA) or an equal 302 Molecular Therapy: Methods & Clinical Development Vol.

Article Title: Modulation of immune responses to liposomal vaccines by intrastructural help.
Article Snippet: .. A total of 30 μg DNA diluted in phosphate-buffered saline without bivalent cations (PBS) was applied i.m. in shaved injection sites using a patch bearing four electrode needles (2.5 mm spacing) with the injection needle in the center (TRiGrid electrode array, Ichor Medical, San Diego, CA, USA) immediately followed by an electrical pulse of 63 V amplitude and 40 ms duration. ..

Article Title: Plasmid-Mediated Gene Therapy in Mouse Models of Limb Girdle Muscular Dystrophy
Article Snippet: .. Plasmid DNA was injected into mouse hind limb muscles using intramuscular injection with a needle attached to the Ichor TriGrid electrode array (Ichor Medical Systems, San Diego, CA, USA). .. Briefly, mice were anesthetized with isoflurane, fur was removed, and 25 or 50 μg of plasmid DNA in 50 μl Hank’s balanced salt solution (HBSS; ThermoFisher Scientific, Waltham, MA, USA) or an equal volume of HBSS buffer alone were injected through the skin into the quadriceps or gastrocnemius muscle using a 0.3 mL syringe (Becton Dickinson, Franklin Lakes, NJ, USA) with attached 1⁄2” 30G needle (Becton Dickinson Ultra-Fine 328431), inserted through the rodent TriGrid electrode array (Ichor).

Article Title: A pair of non-competing neutralizing human monoclonal antibodies protecting from disease in a SARS-CoV-2 infection model
Article Snippet: Briefly, a total of 30 μg DNA diluted in 60 μl PBS were injected in both hind legs under constant isoflurane (CP-Pharma, Burgdorf, Germany) anesthesia. .. Immediately after the intramuscular injection, electrical impulses were applied to the injection site with a TriGrid electrode array (provided by Drew Hannaman, Ichor Medical Systems, Inc., San Diego, USA). .. Mice were boosted intramuscularly either with i) 5 μg of the S protein of SARS-CoV-2 stabilized in a pre-fusion conformation (designated SARS-CoV-2-S protein) and adjuvanted with 25 μg Monophosphoryl Lipid A (MPLA) liposomes (Polymun Scientific GmbH, Klosterneuburg, Austria) into the hind leg, ii) by electroporation of the DNA vaccines used for priming, or iii) with exosomes purified from HEK-293T cells transiently transfected with SARS-CoV-2 DNA as described previously [ ].

Article Title: Antigen-dependent modulation of immune responses to antigen-Fc fusion proteins by Fc-effector functions
Article Snippet: .. Employing a 2.5mm 4-electrode array, BALB/c mice were injected with 20μg DNA in each m. gastrocnemius muscle (40μg total per animal) followed by electric pulses of 63V for 40ms with the TriGrid electrode array (Ichor Medical, San Diego, CA, USA). ..

Plasmid Preparation:

Article Title: Antibodies with improved stability to intestinal digestion, polynucleotides thereof and methods of use thereof to treat disease
Article Snippet: A strong antibody response to a protein antigen can be induced by vaccination of cattle with a DNA vector containing a gene encoding the desired antigen (see, e.g., van Drunen Little-van den Hurk et al., Clin Vaccine Immunol 2013; 20:166-73). .. Individual animals are injected in the right gluteus maximus muscle with 1.5 mg of plasmid DNA in 1 mL, followed by application of a 250-V/cm electrical field for 400 ms at a 10% duty cycle, using a TriGrid electrode array (Ichor Medical Systems). ..

Article Title: Plasmid-Mediated Gene Therapy in Mouse Models of Limb Girdle Muscular Dystrophy.
Article Snippet: .. Plasmid DNAwas injected into mouse hind limbmuscles using intramuscular injection with a needle attached to the Ichor TriGrid electrode array (Ichor Medical Systems, San Diego, CA, USA). .. Briefly, mice were anesthetized with isoflurane, fur was removed, and 25 or 50 mg of plasmid DNA in 50 ml Hank’s balanced salt solution (HBSS; ThermoFisher Scientific, Waltham, MA, USA) or an equal 302 Molecular Therapy: Methods & Clinical Development Vol.

Article Title: Plasmid-Mediated Gene Therapy in Mouse Models of Limb Girdle Muscular Dystrophy
Article Snippet: .. Plasmid DNA was injected into mouse hind limb muscles using intramuscular injection with a needle attached to the Ichor TriGrid electrode array (Ichor Medical Systems, San Diego, CA, USA). .. Briefly, mice were anesthetized with isoflurane, fur was removed, and 25 or 50 μg of plasmid DNA in 50 μl Hank’s balanced salt solution (HBSS; ThermoFisher Scientific, Waltham, MA, USA) or an equal volume of HBSS buffer alone were injected through the skin into the quadriceps or gastrocnemius muscle using a 0.3 mL syringe (Becton Dickinson, Franklin Lakes, NJ, USA) with attached 1⁄2” 30G needle (Becton Dickinson Ultra-Fine 328431), inserted through the rodent TriGrid electrode array (Ichor).

Saline:

Article Title: Modulation of immune responses to liposomal vaccines by intrastructural help.
Article Snippet: .. A total of 30 μg DNA diluted in phosphate-buffered saline without bivalent cations (PBS) was applied i.m. in shaved injection sites using a patch bearing four electrode needles (2.5 mm spacing) with the injection needle in the center (TRiGrid electrode array, Ichor Medical, San Diego, CA, USA) immediately followed by an electrical pulse of 63 V amplitude and 40 ms duration. ..

Muscles:

Article Title: Plasmid-Mediated Gene Therapy in Mouse Models of Limb Girdle Muscular Dystrophy
Article Snippet: .. Plasmid DNA was injected into mouse hind limb muscles using intramuscular injection with a needle attached to the Ichor TriGrid electrode array (Ichor Medical Systems, San Diego, CA, USA). .. Briefly, mice were anesthetized with isoflurane, fur was removed, and 25 or 50 μg of plasmid DNA in 50 μl Hank’s balanced salt solution (HBSS; ThermoFisher Scientific, Waltham, MA, USA) or an equal volume of HBSS buffer alone were injected through the skin into the quadriceps or gastrocnemius muscle using a 0.3 mL syringe (Becton Dickinson, Franklin Lakes, NJ, USA) with attached 1⁄2” 30G needle (Becton Dickinson Ultra-Fine 328431), inserted through the rodent TriGrid electrode array (Ichor).

other:

Article Title: Modulation of immune responses to liposomal vaccines by intrastructural help
Article Snippet: A total of 30 μg DNA diluted in phosphate-buffered saline without bivalent cations (PBS) was applied i.m. in shaved injection sites using a patch bearing four electrode needles (2.5 mm spacing) with the injection needle in the center (TRi-Grid electrode array, Ichor Medical, San Diego, CA, USA) immediately followed by an electrical pulse of 63 V amplitude and 40 ms duration.



Similar Products

90
Ichor Medical ichor trigrid electrode array
Ichor Trigrid Electrode Array, supplied by Ichor Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ichor+trigrid+electrode+array/trigrid+electrode+array/pm31890729-227-16-20
Average 90 stars, based on 1 article reviews
ichor trigrid electrode array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results