Review




Structured Review

BIOSAXS GmbH graphical user interface (gui) of becquerel
Schematic overview of the organization of the communication in <t>BECQUEREL</t> . The main interface has two major tasks: (i) controlling all devices at the beamline in a flexible manner and (ii) setting-up and triggering the data collection. All tasks, data collections and beamline optics are initiated through BECQUEREL , but an intermediary agent, the BMS, executes the commands during data collection. The communication is further mediated by an abstract communication layer, TINE, followed by the device specific servers that communicate directly to the hardware. BECQUEREL has different profiles for allowing smooth measurement and control of the different sample environments available at P12 ( a , robotic; b , SEC-SAXS; c , stop-flow; d , microfluidic spinning disk; e , in-air samples). Abstraction in the representation of the hardware makes it easy to establish communication following a switch between, for example, the four detectors or the two monochromators available. HFM and VFM refer to horizontal and vertical focusing mirror, respectively.
Graphical User Interface (Gui) Of Becquerel, supplied by BIOSAXS GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/graphical+user+interface++gui++of+becquerel/pmc05929361-27-11-13
Average 90 stars, based on 1 article reviews
graphical user interface (gui) of becquerel - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY"

Article Title: Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY

Journal: Journal of Synchrotron Radiation

doi: 10.1107/S1600577518005398

Schematic overview of the organization of the communication in BECQUEREL . The main interface has two major tasks: (i) controlling all devices at the beamline in a flexible manner and (ii) setting-up and triggering the data collection. All tasks, data collections and beamline optics are initiated through BECQUEREL , but an intermediary agent, the BMS, executes the commands during data collection. The communication is further mediated by an abstract communication layer, TINE, followed by the device specific servers that communicate directly to the hardware. BECQUEREL has different profiles for allowing smooth measurement and control of the different sample environments available at P12 ( a , robotic; b , SEC-SAXS; c , stop-flow; d , microfluidic spinning disk; e , in-air samples). Abstraction in the representation of the hardware makes it easy to establish communication following a switch between, for example, the four detectors or the two monochromators available. HFM and VFM refer to horizontal and vertical focusing mirror, respectively.
Figure Legend Snippet: Schematic overview of the organization of the communication in BECQUEREL . The main interface has two major tasks: (i) controlling all devices at the beamline in a flexible manner and (ii) setting-up and triggering the data collection. All tasks, data collections and beamline optics are initiated through BECQUEREL , but an intermediary agent, the BMS, executes the commands during data collection. The communication is further mediated by an abstract communication layer, TINE, followed by the device specific servers that communicate directly to the hardware. BECQUEREL has different profiles for allowing smooth measurement and control of the different sample environments available at P12 ( a , robotic; b , SEC-SAXS; c , stop-flow; d , microfluidic spinning disk; e , in-air samples). Abstraction in the representation of the hardware makes it easy to establish communication following a switch between, for example, the four detectors or the two monochromators available. HFM and VFM refer to horizontal and vertical focusing mirror, respectively.

Techniques Used: Control

Screen-shot of the BECQUEREL GUI. ( a ) Left-most widgets give an overview of monitor readings specific to the profile, and a view of the sample holder (here, robotic sample-changer mode with a capillary view). The central widget accepts sample specifications of the user and displays the well structure of the sample holder. The upper right corner widget contains the status of the BMS and the current command queue. The queue can be paused, cleared and aborted (row of buttons). The Recommender widget (lower right corner) suggests commands and appropriate actions to take to allow for a data collection. Convenient shortcuts in the form of buttons are available in the top row, for submitting measurements and normalization measurements, breaking interlocks and accessing the data-collection directory. ( b ) Plot-tab, here showing transmitted beam over time during a robotic sample changer data collection. ( c ) Hardware tree-tab, with the hardware widget of a guard slit motor shown.
Figure Legend Snippet: Screen-shot of the BECQUEREL GUI. ( a ) Left-most widgets give an overview of monitor readings specific to the profile, and a view of the sample holder (here, robotic sample-changer mode with a capillary view). The central widget accepts sample specifications of the user and displays the well structure of the sample holder. The upper right corner widget contains the status of the BMS and the current command queue. The queue can be paused, cleared and aborted (row of buttons). The Recommender widget (lower right corner) suggests commands and appropriate actions to take to allow for a data collection. Convenient shortcuts in the form of buttons are available in the top row, for submitting measurements and normalization measurements, breaking interlocks and accessing the data-collection directory. ( b ) Plot-tab, here showing transmitted beam over time during a robotic sample changer data collection. ( c ) Hardware tree-tab, with the hardware widget of a guard slit motor shown.

Techniques Used:

Overview of the slit scan functionality in BECQUEREL using the first slit after the monochromator. ( a ) Results of a slit scan with GGCDF and GGPDF fits to the experimental data and numerical derivatives. Re-scans can be made, and data appended to supplement the scan range. ( b ) Result of a fully automated positioning of a slit system. Data represented as beam profiles described by GGPDF are plotted in MATLAB. ( c ) Data from an adaptive scan (three steps) of one slit blade.
Figure Legend Snippet: Overview of the slit scan functionality in BECQUEREL using the first slit after the monochromator. ( a ) Results of a slit scan with GGCDF and GGPDF fits to the experimental data and numerical derivatives. Re-scans can be made, and data appended to supplement the scan range. ( b ) Result of a fully automated positioning of a slit system. Data represented as beam profiles described by GGPDF are plotted in MATLAB. ( c ) Data from an adaptive scan (three steps) of one slit blade.

Techniques Used:

Related Articles

other:

Article Title: Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY
Article Snippet: At the P12 BioSAXS beamline, the graphical user interface (GUI) of BECQUEREL ( Biosaxs Experiment Control QUEue and RELax ) provides the necessary combination of flexibility and automation to efficiently operate a multi-set-up beamline.

Article Title: Integrated beamline control and data acquisition for small-angle X-ray scattering at the P12 BioSAXS beamline at PETRAIII storage ring DESY
Article Snippet: At the P12 BioSAXS beamline, the graphical user interface (GUI) of BECQUEREL (Biosaxs Experiment Control QUEue and RELax) provides the necessary combination of flexibility and automation to efficiently operate a multi-set-up beamline.



Similar Products

86
Molecular Dynamics Inc w charmm gui drude prepper
W Charmm Gui Drude Prepper, supplied by Molecular Dynamics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/charmm+gui/pm42319231-336-7-12
Average 86 stars, based on 1 article reviews
w charmm gui drude prepper - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Molecular Dynamics Inc charmm gui
Charmm Gui, supplied by Molecular Dynamics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/charmm+gui/pm42298186-59-8-0
Average 86 stars, based on 1 article reviews
charmm gui - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Molecular Dynamics Inc charmm gui platform
Charmm Gui Platform, supplied by Molecular Dynamics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/charmm+gui/pmc13054616-111-17-0
Average 86 stars, based on 1 article reviews
charmm gui platform - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Heathrow Scientific gui 600
Gui 600, supplied by Heathrow Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/600+gui/us12626604-168-5-16
Average 86 stars, based on 1 article reviews
gui 600 - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Innov X Systems interactive gui
Interactive Gui, supplied by Innov X Systems, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/gui+interactive/pm42045328-792-11-13
Average 86 stars, based on 1 article reviews
interactive gui - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Grafana Labs matplotlib gui
Matplotlib Gui, supplied by Grafana Labs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/gui+matplotlib/pm41892049-5-7-9
Average 86 stars, based on 1 article reviews
matplotlib gui - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Molecular Dynamics Inc harmm gui
Harmm Gui, supplied by Molecular Dynamics Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/gui+harmm/pm41873931-326-14-2
Average 86 stars, based on 1 article reviews
harmm gui - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

86
Sanofi guy de bruyn
Guy De Bruyn, supplied by Sanofi, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/gui/pm41730823-237-0-7
Average 86 stars, based on 1 article reviews
guy de bruyn - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

Image Search Results