Siemens AG 3d maximum a posteriori (3d-map) algorithm
Noise versus resolution plots (a) at the CFOV and (b) at 8 mm offset for 2D-FBP, 2D-OSEM, <t>and</t> <t>3D-MAP</t> with various β values.
3d Maximum A Posteriori (3d Map) Algorithm, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genetic+algorithm+based+on+the+maximum+entropy+method/3d+maximum+a+posteriori++3d+map++algorithm/pmc03281972-59-1-11
Average 90 stars, based on 1 article reviews
3d maximum a posteriori (3d-map) algorithm - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals"

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals

Journal: Medical Physics

doi: 10.1118/1.3678489

Noise versus resolution plots (a) at the CFOV and (b) at 8 mm offset for 2D-FBP, 2D-OSEM, and 3D-MAP with various β values.
Figure Legend Snippet: Noise versus resolution plots (a) at the CFOV and (b) at 8 mm offset for 2D-FBP, 2D-OSEM, and 3D-MAP with various β values.

Techniques Used:

Activity concentration ratio between spheres and surrounding background area for (a) 2D-FBP, (b) 2D-OSEM, (c) 3D-MAP β = 0, (d) 3D-MAP β = 0.01, (e) 3D-MAP β = 0.1 and (f) 3D-MAP β = 0.5) with various scan durations. Error bars indicate statistical uncertainty over the different realizations. A ratio of 10.11 indicates complete recovery of the activity. The count densities in the background area were multiplied by 10 for this presentation.
Figure Legend Snippet: Activity concentration ratio between spheres and surrounding background area for (a) 2D-FBP, (b) 2D-OSEM, (c) 3D-MAP β = 0, (d) 3D-MAP β = 0.01, (e) 3D-MAP β = 0.1 and (f) 3D-MAP β = 0.5) with various scan durations. Error bars indicate statistical uncertainty over the different realizations. A ratio of 10.11 indicates complete recovery of the activity. The count densities in the background area were multiplied by 10 for this presentation.

Techniques Used: Activity Assay, Concentration Assay

Activity concentration of the spheres filled with 11C and background area filled with 18F solution plotted as a function of time for (a) 2D-FBP and (b) 3D-MAP (20 iterations and β = 0.05).
Figure Legend Snippet: Activity concentration of the spheres filled with 11C and background area filled with 18F solution plotted as a function of time for (a) 2D-FBP and (b) 3D-MAP (20 iterations and β = 0.05).

Techniques Used: Activity Assay, Concentration Assay

Transverse and coronal images of the mouse myocardial phantom filled with 11C and reconstructed with (a)–(b) 2D-FBP and (c)–(d) 3D-MAP (20 iterations, β = 0.05).
Figure Legend Snippet: Transverse and coronal images of the mouse myocardial phantom filled with 11C and reconstructed with (a)–(b) 2D-FBP and (c)–(d) 3D-MAP (20 iterations, β = 0.05).

Techniques Used:

(a) The MAP gated image showing the small ROI traced inside the left ventricle of a mouse injected with 0.5 mCi (18.5 MBq) of 18F-FDG. (b) Blood activity concentrations derived from the ROI shown in (a). Images were reconstructed with 2D-FBP and 3D-MAP (20 iterations, β = 0.05). EKG data (at diastole) are also presented.
Figure Legend Snippet: (a) The MAP gated image showing the small ROI traced inside the left ventricle of a mouse injected with 0.5 mCi (18.5 MBq) of 18F-FDG. (b) Blood activity concentrations derived from the ROI shown in (a). Images were reconstructed with 2D-FBP and 3D-MAP (20 iterations, β = 0.05). EKG data (at diastole) are also presented.

Techniques Used: Injection, Activity Assay, Derivative Assay

Related Articles

Activity Assay:

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
Article Snippet: The 3D maximum a posteriori (3D-MAP) algorithm 3 distributed with the Siemens PreClinical Solution microPET cameras is such an algorithm and implements these corrections (with the exception of the positron range correction).

Concentration Assay:

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
Article Snippet: The 3D maximum a posteriori (3D-MAP) algorithm 3 distributed with the Siemens PreClinical Solution microPET cameras is such an algorithm and implements these corrections (with the exception of the positron range correction).

Injection:

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
Article Snippet: The 3D maximum a posteriori (3D-MAP) algorithm 3 distributed with the Siemens PreClinical Solution microPET cameras is such an algorithm and implements these corrections (with the exception of the positron range correction).

Derivative Assay:

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
Article Snippet: The 3D maximum a posteriori (3D-MAP) algorithm 3 distributed with the Siemens PreClinical Solution microPET cameras is such an algorithm and implements these corrections (with the exception of the positron range correction).

Positron Emission Tomography:

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
Article Snippet: The 3D maximum a posteriori (3D-MAP) algorithm 3 distributed with the Siemens PreClinical Solution microPET cameras is such an algorithm and implements these corrections (with the exception of the positron range correction).

Imaging:

Article Title: Quantitative accuracy of MAP reconstruction for dynamic PET imaging in small animals
Article Snippet: The 3D maximum a posteriori (3D-MAP) algorithm 3 distributed with the Siemens PreClinical Solution microPET cameras is such an algorithm and implements these corrections (with the exception of the positron range correction).



Similar Products

90
Thermo Fisher genetic algorithm based on the maximum entropy method
Genetic Algorithm Based On The Maximum Entropy Method, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/genetic+algorithm+based+on+the+maximum+entropy+method/genetic+algorithm/10__1063_slash_1__5131030-93-7-11
Average 90 stars, based on 1 article reviews
genetic algorithm based on the maximum entropy method - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results