Review




Structured Review

Philips Healthcare dti post processing
a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the <t>DTI</t> parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, <t>Diffusion</t> <t>tensor</t> <t>imaging;</t> FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest
Dti Post Processing, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dti+post+processing/post+processing+workstation/pmc12586801-174-4-10
Average 86 stars, based on 1 article reviews
dti post processing - by Bioz Stars, 2026-10
86/100 stars

Images

1) Product Images from "DTI changes of brachial plexus nerve roots in amyotrophic lateral sclerosis and their correlation with electrophysiology"

Article Title: DTI changes of brachial plexus nerve roots in amyotrophic lateral sclerosis and their correlation with electrophysiology

Journal: European Radiology Experimental

doi: 10.1186/s41747-025-00645-3

a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the DTI parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, Diffusion tensor imaging; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest
Figure Legend Snippet: a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the DTI parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, Diffusion tensor imaging; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest

Techniques Used: Control, Diffusion-based Assay, Imaging

Diffusion tensor imaging parameters of ALS patients and healthy volunteers. * p < 0.05; ** p < 0.01. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity
Figure Legend Snippet: Diffusion tensor imaging parameters of ALS patients and healthy volunteers. * p < 0.05; ** p < 0.01. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity

Techniques Used: Diffusion-based Assay, Imaging

Correlations between diffusion tensor imaging parameters of brachial plexus nerve roots and ALSFRS-R score, ALSFRS-UL score, electrophysiological of median nerve (MN), ulnar nerve (UN) and radial nerve (RN). Correlation of FA ( a ), AD ( b ), RD ( c ), and MD ( d ) with ALSFRS-R score, ALSFRS-UL score, electrophysiological of MN, UN and RN, respectively. AD, Axial diffusivity; ALSFRS-R, Amyotrophic lateral sclerosis functional rating scale-revised; ALSFRS-UL, ALSFRS-upper limb; CMAP, Compound muscle action potential; FA, Fractional anisotropy; MCV, Motor nerve conduction velocity; MD, Mean diffusivity; RD, Radial diffusivity
Figure Legend Snippet: Correlations between diffusion tensor imaging parameters of brachial plexus nerve roots and ALSFRS-R score, ALSFRS-UL score, electrophysiological of median nerve (MN), ulnar nerve (UN) and radial nerve (RN). Correlation of FA ( a ), AD ( b ), RD ( c ), and MD ( d ) with ALSFRS-R score, ALSFRS-UL score, electrophysiological of MN, UN and RN, respectively. AD, Axial diffusivity; ALSFRS-R, Amyotrophic lateral sclerosis functional rating scale-revised; ALSFRS-UL, ALSFRS-upper limb; CMAP, Compound muscle action potential; FA, Fractional anisotropy; MCV, Motor nerve conduction velocity; MD, Mean diffusivity; RD, Radial diffusivity

Techniques Used: Diffusion-based Assay, Imaging, Functional Assay

Related Articles

other:

Article Title: Left atrioventricular coupling index assessed by cardiac CT as a predictive marker for atrial fibrillation recurrence after ablation
Article Snippet: The acquired images were processed using the Philips post-processing workstation.

Magnetic Resonance Imaging:

Article Title: Quantitative MRI Markers Detect Post-Pancreatitis Changes and Diabetes: A Prospective Cohort Study.
Article Snippet: .. Image Analysis A vendor-neutral post-processing platform (IntelliSpace, Philips Healthcare) was used to obtain data for each MRI marker except pancreas volume. ..

Marker:

Article Title: Quantitative MRI Markers Detect Post-Pancreatitis Changes and Diabetes: A Prospective Cohort Study.
Article Snippet: .. Image Analysis A vendor-neutral post-processing platform (IntelliSpace, Philips Healthcare) was used to obtain data for each MRI marker except pancreas volume. ..

Software:

Article Title: Predictive value of dynamic contrast enhanced magnetic resonance imaging and diffusion-weighted imaging in pancreatic cancer invasion and metastasis.
Article Snippet: Objective: To explore the clinical value of parameters of dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) in the diagnosis of pancreatic cancer and its invasiveness prediction.. Materials and methods: A total of 122 participants, comprising 58 patients with pathologically confirmed pancreatic cancer (median age 60.50 years [interquartile range, 54.00–65.25 years]; 38 males), 34 pancreatitis patients (median age 55.50 years[interquartile range, 43.00–67.25 years]; 23 males), and 30 healthy volunteers (median age 52.00 years[interquartile range, 36.00–62.25 years]; 16 males), underwent DWI and DCE-MRI scans.. The values of Ktrans (volume transfer constant), Kep (rate constant), Ve (extravascular extracellular volume fraction), Vp (plasma volume fraction), TTP (Time to Peak), MAX Conc (Maximum Concentration), AUC (Area Under the Curve), and MAXSlope (Maximum Slope) from DCE sequence as well as the values of ADC and eADC from DWI sequence were collected.

Article Title: Early detection of type 2 diabetes mellitus‐associated cognitive dysfunction: The potential of amide proton transfer‐weighted imaging
Article Snippet: .. APTw data were imported into the post‐processing ‘IntelliSpace Portal’ software (Philips Healthcare, Best, Netherlands). ..

Article Title: High agreement of coronary artery calcification scores between full-dose (6.5 ​mSv) and reduced-dose (1.5 ​mSv) chest computed tomography: A retrospective analysis of COPDGene.
Article Snippet: All images were interpreted at the Imaging Center at The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, a participating COPDGene site. .. CAC scoring was performed on the inspiratory scan using commercially available post-processing software (Philips IntelliSpace Portal, Philips Healthcare). ..



Similar Products

86
Cytiva Europe dti post processing software
Dti Post Processing Software, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dti+post+processing/10__1097_slash_brs__0000000000003925-50-5-15
Average 86 stars, based on 1 article reviews
dti post processing software - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Philips Healthcare dti post processing
a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the <t>DTI</t> parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, <t>Diffusion</t> <t>tensor</t> <t>imaging;</t> FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest
Dti Post Processing, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dti+post+processing/post+processing+workstation/pmc12586801-174-4-10
Average 86 stars, based on 1 article reviews
dti post processing - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Philips Healthcare dti data post processing software
a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the <t>DTI</t> parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, <t>Diffusion</t> <t>tensor</t> <t>imaging;</t> FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest
Dti Data Post Processing Software, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/dti+post+processing/dti+processing+software/pm21831603-70-6-6
Average 90 stars, based on 1 article reviews
dti data post processing software - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the DTI parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, Diffusion tensor imaging; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest

Journal: European Radiology Experimental

Article Title: DTI changes of brachial plexus nerve roots in amyotrophic lateral sclerosis and their correlation with electrophysiology

doi: 10.1186/s41747-025-00645-3

Figure Lengend Snippet: a ROI placement: three ROIs were placed at 1, 2, and 3 cm from the ganglion on each nerve root to measure the DTI parameter values of the nerve. b DTI raw image of an ALS patient. c DTI raw image of a healthy control. ( d – g ) FA, AD, RD, and MD parameter maps of the ALS patient. ( h – k FA, AD, RD, and MD parameter maps of the healthy control. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; DTI, Diffusion tensor imaging; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity; ROI, Region of interest

Article Snippet: Fourthly, in this study, DTI post-processing was performed using the Philips ISP workstation, a dedicated and standardized research platform provided by Philips.

Techniques: Control, Diffusion-based Assay, Imaging

Diffusion tensor imaging parameters of ALS patients and healthy volunteers. * p < 0.05; ** p < 0.01. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity

Journal: European Radiology Experimental

Article Title: DTI changes of brachial plexus nerve roots in amyotrophic lateral sclerosis and their correlation with electrophysiology

doi: 10.1186/s41747-025-00645-3

Figure Lengend Snippet: Diffusion tensor imaging parameters of ALS patients and healthy volunteers. * p < 0.05; ** p < 0.01. AD, Axial diffusivity; ALS, Amyotrophic lateral sclerosis; FA, Fractional anisotropy; MD, Mean diffusivity; RD, Radial diffusivity

Article Snippet: Fourthly, in this study, DTI post-processing was performed using the Philips ISP workstation, a dedicated and standardized research platform provided by Philips.

Techniques: Diffusion-based Assay, Imaging

Correlations between diffusion tensor imaging parameters of brachial plexus nerve roots and ALSFRS-R score, ALSFRS-UL score, electrophysiological of median nerve (MN), ulnar nerve (UN) and radial nerve (RN). Correlation of FA ( a ), AD ( b ), RD ( c ), and MD ( d ) with ALSFRS-R score, ALSFRS-UL score, electrophysiological of MN, UN and RN, respectively. AD, Axial diffusivity; ALSFRS-R, Amyotrophic lateral sclerosis functional rating scale-revised; ALSFRS-UL, ALSFRS-upper limb; CMAP, Compound muscle action potential; FA, Fractional anisotropy; MCV, Motor nerve conduction velocity; MD, Mean diffusivity; RD, Radial diffusivity

Journal: European Radiology Experimental

Article Title: DTI changes of brachial plexus nerve roots in amyotrophic lateral sclerosis and their correlation with electrophysiology

doi: 10.1186/s41747-025-00645-3

Figure Lengend Snippet: Correlations between diffusion tensor imaging parameters of brachial plexus nerve roots and ALSFRS-R score, ALSFRS-UL score, electrophysiological of median nerve (MN), ulnar nerve (UN) and radial nerve (RN). Correlation of FA ( a ), AD ( b ), RD ( c ), and MD ( d ) with ALSFRS-R score, ALSFRS-UL score, electrophysiological of MN, UN and RN, respectively. AD, Axial diffusivity; ALSFRS-R, Amyotrophic lateral sclerosis functional rating scale-revised; ALSFRS-UL, ALSFRS-upper limb; CMAP, Compound muscle action potential; FA, Fractional anisotropy; MCV, Motor nerve conduction velocity; MD, Mean diffusivity; RD, Radial diffusivity

Article Snippet: Fourthly, in this study, DTI post-processing was performed using the Philips ISP workstation, a dedicated and standardized research platform provided by Philips.

Techniques: Diffusion-based Assay, Imaging, Functional Assay