Review



ex vivo diffusion tensor imaging dti  (Bruker Corporation)


Bioz Verified Symbol Bruker Corporation is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Bruker Corporation ex vivo diffusion tensor imaging dti
    Ex Vivo Diffusion Tensor Imaging Dti, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 3080 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/Diffusion/pm40609698-53-0-16
    Average 97 stars, based on 3080 article reviews
    ex vivo diffusion tensor imaging dti - by Bioz Stars, 2026-09
    97/100 stars

    Images

    Related Articles

    Mass Spectrometry:

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited
    Article Snippet: .. Gu (2024) [ ] , Skin swab , MALDI-TOF Mass Spectrometry (Bruker) , Kirby Bauer disk diffusion test (Etest) , CLSI , PEN-susceptible. .. Lampejo (2024) [ ] , Blood culture , MALDI-TOF Mass Spectrometry , Kirby Bauer disk diffusion test , EUCAST , CLI-, PEN-, VA-susceptible. MTZ-resistant.

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited.
    Article Snippet: .. Author Year Reference Type of Sample Method of Identification Method ofSusceptibility Testing Interpretation Criteria Antibiotics Resistance Phenotype (MIC mg/L) Chinello (2025) [28] Material drained from orbital cellulitis MALDI-TOF Mass Spectrometry NR NR AMC < 0.016, AZY 2, CLI > 256, DAPTO 4, LZD 0.19, MEM 0.012, MTZ > 256, TZP < 0.016 Faiz (2025) [29] Intraoperative sample from abscess MALDI-TOF Mass Spectrometry (Bruker) Kirby Bauer disk diffusion test EUCAST 2023 breakpoint for Corynebacterium CLI-, LIN-, RIF-, TET-susceptible CIP-, MOX-, PEN-, SXT-, VA-resistant Lovering (2025) [30] Blood culture MALDI-TOF MassSpectrometry NR NR CN, CRO, LZD, MEM, PEN, VA susceptible Saijo (2025) [31] Intraoperative sample from debridement MALDI-TOF Mass Spectrometry NR NR CRO 0.5, FEP 2, CTX 0.5, ERY < 0.12, PEN 0.25, RIF < 1, SXT < 0.5, VA 0.5 Bozso (2024) [32] Blood culture NR NR NR CLI ≤ 0.016, PEN ≤ 0.03 Chang (2024) [33] Blood culture, intraoperative samples from abscess NR NR NR NR Chin (2024) [34] Intraoperative sample from abscess NR NR NR NR Grusiecki (2024) [35] Purulent material from abscess NR NR NR PEN-susceptible CIP-, CLI-, MXF-resistant Gu (2024) [36] Skin swab MALDI-TOF Mass Spectrometry (Bruker) Kirby Bauer disk diffusion test (Etest) CLSI PEN-susceptible https://doi.org/10.3390/pathogens15030335 Table 3. ..

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited.
    Article Snippet: .. MTZ-resistant Alrwashdeh (2023) [38] Blood culture and BAL MALDI-TOF MassSpectrometry NR PEN-susceptible Herai (2023) [39] Pleural fluid MALDI-TOF Mass Spectrometry (Bruker) NR NR NR Sahhar (2023) [40] Intraoperative sample from abscess MALDI-TOF Mass Spectrometry (Bruker) Kirby Bauer diffusion test (Disks and Etest) NR CLI-, CRO-, DOX-, LEV-, LZD-, PEN, RIF-, VA-susceptible Hicks (2022) [41] Intraoperative sample from abscess MALDI-TOF Mass Spectrometry Kirby Bauer diffusion test (Etest) NR PEN 0.064 Thomas (2022) [42] Intraoperative sample from debridement NR NR NR NR Purulent material from wound NR NR NR NR Purulent material from wound NR NR NR NR Intraoperative sample from debridement NR NR NR NR Intraoperative sample from debridement NR NR NR NR Purulent material from ulcer NR NR NR NR https://doi.org/10.3390/pathogens15030335 Table 3. ..

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited
    Article Snippet: Herai (2023) [ ] , Pleural fluid , MALDI-TOF Mass Spectrometry (Bruker) , NR , NR , NR. .. Sahhar (2023) [ ] , Intraoperative sample from abscess , MALDI-TOF Mass Spectrometry (Bruker) , Kirby Bauer diffusion test (Disks and Etest) , NR , CLI-, CRO-, DOX-, LEV-, LZD-, PEN, RIF-, VA-susceptible. .. Hicks (2022) [ ] , Intraoperative sample from abscess , MALDI-TOF Mass Spectrometry , Kirby Bauer diffusion test (Etest) , NR , PEN 0.064.

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited
    Article Snippet: Chinello (2025) [ ] , Material drained from orbital cellulitis , MALDI-TOF Mass Spectrometry , NR , NR , AMC < 0.016, AZY 2, CLI > 256, DAPTO 4, LZD 0.19, MEM 0.012, MTZ > 256, TZP < 0.016. .. Faiz (2025) [ ] , Intraoperative sample from abscess , MALDI-TOF Mass Spectrometry (Bruker) , Kirby Bauer disk diffusion test , EUCAST 2023 breakpoint for Corynebacterium , CLI-, LIN-, RIF-, TET-susceptible CIP-, MOX-, PEN-, SXT-, VA-resistant. .. Lovering (2025) [ ] , Blood culture , MALDI-TOF Mass Spectrometry , NR , NR , CN, CRO, LZD, MEM, PEN, VA susceptible.

    Diffusion-based Assay:

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited
    Article Snippet: .. Gu (2024) [ ] , Skin swab , MALDI-TOF Mass Spectrometry (Bruker) , Kirby Bauer disk diffusion test (Etest) , CLSI , PEN-susceptible. .. Lampejo (2024) [ ] , Blood culture , MALDI-TOF Mass Spectrometry , Kirby Bauer disk diffusion test , EUCAST , CLI-, PEN-, VA-susceptible. MTZ-resistant.

    Article Title: Potassium Hexafluoroacetylacetonate Complex with 18-Crown-6 Ether as a Volatile Precursor of Molecular and Inorganic Films: Thermal and Structural Insights.
    Article Snippet: The 1H DOSY NMR experiment [85,86] was performed on the same equipment with a 5 mm BBI probe with z-gradient. .. Diffusion coefficients were measured using the standard Bruker Ledbpgp2s sequence. ..

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited.
    Article Snippet: .. Author Year Reference Type of Sample Method of Identification Method ofSusceptibility Testing Interpretation Criteria Antibiotics Resistance Phenotype (MIC mg/L) Chinello (2025) [28] Material drained from orbital cellulitis MALDI-TOF Mass Spectrometry NR NR AMC < 0.016, AZY 2, CLI > 256, DAPTO 4, LZD 0.19, MEM 0.012, MTZ > 256, TZP < 0.016 Faiz (2025) [29] Intraoperative sample from abscess MALDI-TOF Mass Spectrometry (Bruker) Kirby Bauer disk diffusion test EUCAST 2023 breakpoint for Corynebacterium CLI-, LIN-, RIF-, TET-susceptible CIP-, MOX-, PEN-, SXT-, VA-resistant Lovering (2025) [30] Blood culture MALDI-TOF MassSpectrometry NR NR CN, CRO, LZD, MEM, PEN, VA susceptible Saijo (2025) [31] Intraoperative sample from debridement MALDI-TOF Mass Spectrometry NR NR CRO 0.5, FEP 2, CTX 0.5, ERY < 0.12, PEN 0.25, RIF < 1, SXT < 0.5, VA 0.5 Bozso (2024) [32] Blood culture NR NR NR CLI ≤ 0.016, PEN ≤ 0.03 Chang (2024) [33] Blood culture, intraoperative samples from abscess NR NR NR NR Chin (2024) [34] Intraoperative sample from abscess NR NR NR NR Grusiecki (2024) [35] Purulent material from abscess NR NR NR PEN-susceptible CIP-, CLI-, MXF-resistant Gu (2024) [36] Skin swab MALDI-TOF Mass Spectrometry (Bruker) Kirby Bauer disk diffusion test (Etest) CLSI PEN-susceptible https://doi.org/10.3390/pathogens15030335 Table 3. ..

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited.
    Article Snippet: .. MTZ-resistant Alrwashdeh (2023) [38] Blood culture and BAL MALDI-TOF MassSpectrometry NR PEN-susceptible Herai (2023) [39] Pleural fluid MALDI-TOF Mass Spectrometry (Bruker) NR NR NR Sahhar (2023) [40] Intraoperative sample from abscess MALDI-TOF Mass Spectrometry (Bruker) Kirby Bauer diffusion test (Disks and Etest) NR CLI-, CRO-, DOX-, LEV-, LZD-, PEN, RIF-, VA-susceptible Hicks (2022) [41] Intraoperative sample from abscess MALDI-TOF Mass Spectrometry Kirby Bauer diffusion test (Etest) NR PEN 0.064 Thomas (2022) [42] Intraoperative sample from debridement NR NR NR NR Purulent material from wound NR NR NR NR Purulent material from wound NR NR NR NR Intraoperative sample from debridement NR NR NR NR Intraoperative sample from debridement NR NR NR NR Purulent material from ulcer NR NR NR NR https://doi.org/10.3390/pathogens15030335 Table 3. ..

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited
    Article Snippet: Herai (2023) [ ] , Pleural fluid , MALDI-TOF Mass Spectrometry (Bruker) , NR , NR , NR. .. Sahhar (2023) [ ] , Intraoperative sample from abscess , MALDI-TOF Mass Spectrometry (Bruker) , Kirby Bauer diffusion test (Disks and Etest) , NR , CLI-, CRO-, DOX-, LEV-, LZD-, PEN, RIF-, VA-susceptible. .. Hicks (2022) [ ] , Intraoperative sample from abscess , MALDI-TOF Mass Spectrometry , Kirby Bauer diffusion test (Etest) , NR , PEN 0.064.

    Article Title: Physical and chemical characterisation of ophthalmic lens-grinding wastewater: uncovering environmental implications.
    Article Snippet: .. 1D 1H and 2D 1H-1H NMR DOSY (Diffusion-ordered spectroscopy) experiments were carried out on a 9.4 T Bruker AVANCE III 400 spectrometer (Bruker Corporation, Billerica MA, USA) equipped with a Bruker DiffBB probe, specifically a 5 mm high-power diffusion BBI probe. ..

    Article Title: Insights into Arcanobacterium haemolyticum : A Narrative Review of an Emerging Pathogen Revisited
    Article Snippet: Chinello (2025) [ ] , Material drained from orbital cellulitis , MALDI-TOF Mass Spectrometry , NR , NR , AMC < 0.016, AZY 2, CLI > 256, DAPTO 4, LZD 0.19, MEM 0.012, MTZ > 256, TZP < 0.016. .. Faiz (2025) [ ] , Intraoperative sample from abscess , MALDI-TOF Mass Spectrometry (Bruker) , Kirby Bauer disk diffusion test , EUCAST 2023 breakpoint for Corynebacterium , CLI-, LIN-, RIF-, TET-susceptible CIP-, MOX-, PEN-, SXT-, VA-resistant. .. Lovering (2025) [ ] , Blood culture , MALDI-TOF Mass Spectrometry , NR , NR , CN, CRO, LZD, MEM, PEN, VA susceptible.

    Sequencing:

    Article Title: Potassium Hexafluoroacetylacetonate Complex with 18-Crown-6 Ether as a Volatile Precursor of Molecular and Inorganic Films: Thermal and Structural Insights.
    Article Snippet: The 1H DOSY NMR experiment [85,86] was performed on the same equipment with a 5 mm BBI probe with z-gradient. .. Diffusion coefficients were measured using the standard Bruker Ledbpgp2s sequence. ..

    Nuclear Magnetic Resonance:

    Article Title: Physical and chemical characterisation of ophthalmic lens-grinding wastewater: uncovering environmental implications.
    Article Snippet: .. 1D 1H and 2D 1H-1H NMR DOSY (Diffusion-ordered spectroscopy) experiments were carried out on a 9.4 T Bruker AVANCE III 400 spectrometer (Bruker Corporation, Billerica MA, USA) equipped with a Bruker DiffBB probe, specifically a 5 mm high-power diffusion BBI probe. ..

    Spectroscopy:

    Article Title: Physical and chemical characterisation of ophthalmic lens-grinding wastewater: uncovering environmental implications.
    Article Snippet: .. 1D 1H and 2D 1H-1H NMR DOSY (Diffusion-ordered spectroscopy) experiments were carried out on a 9.4 T Bruker AVANCE III 400 spectrometer (Bruker Corporation, Billerica MA, USA) equipped with a Bruker DiffBB probe, specifically a 5 mm high-power diffusion BBI probe. ..



    Similar Products

    86
    Cell Signaling Technology Inc diffusion tensor imaging dti
    Diffusion Tensor Imaging Dti, supplied by Cell Signaling Technology Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/pmc12829363-90-16-28
    Average 86 stars, based on 1 article reviews
    diffusion tensor imaging dti - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    97
    Bruker Corporation ex vivo diffusion tensor imaging dti
    Ex Vivo Diffusion Tensor Imaging Dti, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/Diffusion/pm40609698-53-0-16
    Average 97 stars, based on 1 article reviews
    ex vivo diffusion tensor imaging dti - by Bioz Stars, 2026-09
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion tensor imaging dti 230
    Diffusion Tensor Imaging Dti 230, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/Diffusion/pm40541777-108-2-24
    Average 97 stars, based on 1 article reviews
    diffusion tensor imaging dti 230 - by Bioz Stars, 2026-09
    97/100 stars
      Buy from Supplier

    90
    WhiteMatter Labs GmbH diffusion tensor imaging (dti)
    Diffusion Tensor Imaging (Dti), supplied by WhiteMatter Labs GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/diffusion+tensor+imaging/pm40075890-40-1-11
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging (dti) - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Johns Hopkins HealthCare diffusion tensor imaging (dti) parameters
    Correlation between <t>diffusion</t> <t>tensor</t> <t>imaging</t> <t>(DTI)</t> parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset. DTI parameters were averaged across all sessions for each participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random slopes and intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. Neither parameter significantly varied with session (Scale for the Assessment of Positive Symptoms [SAPS] t 22.9 = −0.43, p = .66) (SANS t 27.3 = −0.92, p = .36). (B, C) Intercept was computed using a first-order linear model for each participant, with the baseline scan as time 0. Relationships with DTI parameters were tested with a linear model with age and sex and covariates. (B) Significant regions of interest are colored according to their t value. Multiple comparisons were corrected with the false discovery rate. (C) Scatter plots showing DTI parameters averaged across the white matter. Shaded bands show 95% CI computed with nonparametric bootstrap paired resampling with 1000 permutations. Mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) significantly increased with session. Fractional anisotropy (FA) did not significantly change. t Values and p values are shown in <xref ref-type=Table S10 . " width="250" height="auto" />
    Diffusion Tensor Imaging (Dti) Parameters, supplied by Johns Hopkins HealthCare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/diffusion+tensor+imaging/pmc11994302-158-4-23
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging (dti) parameters - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion tensor images dti
    Correlation between <t>diffusion</t> <t>tensor</t> <t>imaging</t> <t>(DTI)</t> parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset. DTI parameters were averaged across all sessions for each participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random slopes and intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. Neither parameter significantly varied with session (Scale for the Assessment of Positive Symptoms [SAPS] t 22.9 = −0.43, p = .66) (SANS t 27.3 = −0.92, p = .36). (B, C) Intercept was computed using a first-order linear model for each participant, with the baseline scan as time 0. Relationships with DTI parameters were tested with a linear model with age and sex and covariates. (B) Significant regions of interest are colored according to their t value. Multiple comparisons were corrected with the false discovery rate. (C) Scatter plots showing DTI parameters averaged across the white matter. Shaded bands show 95% CI computed with nonparametric bootstrap paired resampling with 1000 permutations. Mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) significantly increased with session. Fractional anisotropy (FA) did not significantly change. t Values and p values are shown in <xref ref-type=Table S10 . " width="250" height="auto" />
    Diffusion Tensor Images Dti, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/Diffusion/pmc11780150-549-7-17
    Average 97 stars, based on 1 article reviews
    diffusion tensor images dti - by Bioz Stars, 2026-09
    97/100 stars
      Buy from Supplier

    90
    Johns Hopkins HealthCare diffusion tensor imaging (dti)
    Correlation between <t>diffusion</t> <t>tensor</t> <t>imaging</t> <t>(DTI)</t> parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset. DTI parameters were averaged across all sessions for each participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random slopes and intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. Neither parameter significantly varied with session (Scale for the Assessment of Positive Symptoms [SAPS] t 22.9 = −0.43, p = .66) (SANS t 27.3 = −0.92, p = .36). (B, C) Intercept was computed using a first-order linear model for each participant, with the baseline scan as time 0. Relationships with DTI parameters were tested with a linear model with age and sex and covariates. (B) Significant regions of interest are colored according to their t value. Multiple comparisons were corrected with the false discovery rate. (C) Scatter plots showing DTI parameters averaged across the white matter. Shaded bands show 95% CI computed with nonparametric bootstrap paired resampling with 1000 permutations. Mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) significantly increased with session. Fractional anisotropy (FA) did not significantly change. t Values and p values are shown in <xref ref-type=Table S10 . " width="250" height="auto" />
    Diffusion Tensor Imaging (Dti), supplied by Johns Hopkins HealthCare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/diffusion+tensor+imaging/10__3389_slash_frai__2024__1400732-103-2-0
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging (dti) - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Johns Hopkins HealthCare diffusion tensor imaging (dti) / of brain anatomical mri
    Correlation between <t>diffusion</t> <t>tensor</t> <t>imaging</t> <t>(DTI)</t> parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset. DTI parameters were averaged across all sessions for each participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random slopes and intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. Neither parameter significantly varied with session (Scale for the Assessment of Positive Symptoms [SAPS] t 22.9 = −0.43, p = .66) (SANS t 27.3 = −0.92, p = .36). (B, C) Intercept was computed using a first-order linear model for each participant, with the baseline scan as time 0. Relationships with DTI parameters were tested with a linear model with age and sex and covariates. (B) Significant regions of interest are colored according to their t value. Multiple comparisons were corrected with the false discovery rate. (C) Scatter plots showing DTI parameters averaged across the white matter. Shaded bands show 95% CI computed with nonparametric bootstrap paired resampling with 1000 permutations. Mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) significantly increased with session. Fractional anisotropy (FA) did not significantly change. t Values and p values are shown in <xref ref-type=Table S10 . " width="250" height="auto" />
    Diffusion Tensor Imaging (Dti) / Of Brain Anatomical Mri, supplied by Johns Hopkins HealthCare, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/diffusion+tensor+imaging/pmc11665297-12-9-0
    Average 90 stars, based on 1 article reviews
    diffusion tensor imaging (dti) / of brain anatomical mri - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion tensor imaging dti
    Comparison of protocols used by 3 research groups for ultrahigh-resolution imaging of formalin-fixed ex vivo human brain specimens.
    Diffusion Tensor Imaging Dti, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+tensor+imaging+dti/Diffusion/pmc11631901-113-0-22
    Average 97 stars, based on 1 article reviews
    diffusion tensor imaging dti - by Bioz Stars, 2026-09
    97/100 stars
      Buy from Supplier

    Image Search Results


    Correlation between diffusion tensor imaging (DTI) parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset. DTI parameters were averaged across all sessions for each participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random slopes and intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. Neither parameter significantly varied with session (Scale for the Assessment of Positive Symptoms [SAPS] t 22.9 = −0.43, p = .66) (SANS t 27.3 = −0.92, p = .36). (B, C) Intercept was computed using a first-order linear model for each participant, with the baseline scan as time 0. Relationships with DTI parameters were tested with a linear model with age and sex and covariates. (B) Significant regions of interest are colored according to their t value. Multiple comparisons were corrected with the false discovery rate. (C) Scatter plots showing DTI parameters averaged across the white matter. Shaded bands show 95% CI computed with nonparametric bootstrap paired resampling with 1000 permutations. Mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) significantly increased with session. Fractional anisotropy (FA) did not significantly change. t Values and p values are shown in <xref ref-type=Table S10 . " width="100%" height="100%">

    Journal: Biological Psychiatry Global Open Science

    Article Title: Stable White Matter Structure in the First Three Years After Psychosis Onset

    doi: 10.1016/j.bpsgos.2025.100472

    Figure Lengend Snippet: Correlation between diffusion tensor imaging (DTI) parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset. DTI parameters were averaged across all sessions for each participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random slopes and intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. Neither parameter significantly varied with session (Scale for the Assessment of Positive Symptoms [SAPS] t 22.9 = −0.43, p = .66) (SANS t 27.3 = −0.92, p = .36). (B, C) Intercept was computed using a first-order linear model for each participant, with the baseline scan as time 0. Relationships with DTI parameters were tested with a linear model with age and sex and covariates. (B) Significant regions of interest are colored according to their t value. Multiple comparisons were corrected with the false discovery rate. (C) Scatter plots showing DTI parameters averaged across the white matter. Shaded bands show 95% CI computed with nonparametric bootstrap paired resampling with 1000 permutations. Mean diffusivity (MD), radial diffusivity (RD), and axial diffusivity (AD) significantly increased with session. Fractional anisotropy (FA) did not significantly change. t Values and p values are shown in Table S10 .

    Article Snippet: Figure 2 Correlation between diffusion tensor imaging (DTI) parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset.

    Techniques: Diffusion-based Assay, Imaging

    Correlations between diffusion tensor imaging (DTI) parameters and the 8-item Positive and Negative Syndrome Scale-Negative (PANSS8-N) follow-up score in the Tracking Outcomes in Psychosis dataset. DTI measures were averaged across sessions per participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. PANSS8 Positive (PANSS8-P) was significantly lower at the second session ( t 21.0 = −10.9, p < .001). PANSS8-N did not significantly change ( t 21.0 = −0.70, p = .49). (B–D) Participants grouped based on whether their PANSS8-N score at follow-up was equal to 3, the lowest possible score (remission). Relationships with DTI parameters tested with a linear model with age and sex and covariates. Regions of interest from each panel come from different nested hierarchical layers at successively higher resolutions. Multiple comparisons for each layer were corrected with the false discovery rate. All comparisons shown are significant. t Values and p values are shown in <xref ref-type=Table S9 . FA, fractional anisotropy. " width="100%" height="100%">

    Journal: Biological Psychiatry Global Open Science

    Article Title: Stable White Matter Structure in the First Three Years After Psychosis Onset

    doi: 10.1016/j.bpsgos.2025.100472

    Figure Lengend Snippet: Correlations between diffusion tensor imaging (DTI) parameters and the 8-item Positive and Negative Syndrome Scale-Negative (PANSS8-N) follow-up score in the Tracking Outcomes in Psychosis dataset. DTI measures were averaged across sessions per participant. (A) Longitudinal progression of symptoms. Empty circles at baseline show participants with no follow-ups. Trendlines show a linear fixed-effect model of parameter against session with random intercepts fit for every participant. Shaded bands show a 95% CI computed with parametric bootstrapping resampling residuals and random effects 1000 times. PANSS8 Positive (PANSS8-P) was significantly lower at the second session ( t 21.0 = −10.9, p < .001). PANSS8-N did not significantly change ( t 21.0 = −0.70, p = .49). (B–D) Participants grouped based on whether their PANSS8-N score at follow-up was equal to 3, the lowest possible score (remission). Relationships with DTI parameters tested with a linear model with age and sex and covariates. Regions of interest from each panel come from different nested hierarchical layers at successively higher resolutions. Multiple comparisons for each layer were corrected with the false discovery rate. All comparisons shown are significant. t Values and p values are shown in Table S9 . FA, fractional anisotropy.

    Article Snippet: Figure 2 Correlation between diffusion tensor imaging (DTI) parameters and negative symptom (Scale for the Assessment of Negative Symptoms [SANS]) intercepts in the Johns Hopkins Schizophrenia Center dataset.

    Techniques: Diffusion-based Assay, Imaging

    Comparison of protocols used by 3 research groups for ultrahigh-resolution imaging of formalin-fixed ex vivo human brain specimens.

    Journal: Frontiers in Human Neuroscience

    Article Title: Ultrahigh-resolution 7-Tesla anatomic magnetic resonance imaging and diffusion tensor imaging of ex vivo formalin-fixed human brainstem-cerebellum complex

    doi: 10.3389/fnhum.2024.1484431

    Figure Lengend Snippet: Comparison of protocols used by 3 research groups for ultrahigh-resolution imaging of formalin-fixed ex vivo human brain specimens.

    Article Snippet: Diffusion tensor imaging (DTI) lasted 48 h and 48 min, and subsequent anatomical imaging was performed using a 7-Tesla (7T) MRI system (Bruker Biospec 70/30 with 30-cm bore size) equipped with a 70-mm volume coil.

    Techniques: Comparison, Imaging, Ex Vivo, Saline, Sequencing, Diffusion-based Assay, Software