Review



diffusion pulse sequence bppled  (Bruker Corporation)


Bioz Verified Symbol Bruker Corporation is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Bruker Corporation diffusion pulse sequence bppled
    Diffusion Pulse Sequence Bppled, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 2972 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pm41605548-72-23-22?v=Bruker+Corporation
    Average 97 stars, based on 2972 article reviews
    diffusion pulse sequence bppled - by Bioz Stars, 2026-07
    97/100 stars

    Images



    Similar Products

    86
    Philips Healthcare motion compensated diffusion sequence
    Schematic diagram of the analytical procedure for <t>the</t> <t>motion‐compensated</t> diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.
    Motion Compensated Diffusion Sequence, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pmc13156429-158-1-11?v=Philips+Healthcare
    Average 86 stars, based on 1 article reviews
    motion compensated diffusion sequence - by Bioz Stars, 2026-07
    86/100 stars
      Buy from Supplier

    97
    Bruker Corporation 1d pulse sequence
    Schematic diagram of the analytical procedure for <t>the</t> <t>motion‐compensated</t> diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.
    1d Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pmc12992617-217-23-37?v=Bruker+Corporation
    Average 97 stars, based on 1 article reviews
    1d pulse sequence - by Bioz Stars, 2026-07
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion pulse sequence bppled
    Schematic diagram of the analytical procedure for <t>the</t> <t>motion‐compensated</t> diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.
    Diffusion Pulse Sequence Bppled, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pm41605548-72-23-22?v=Bruker+Corporation
    Average 97 stars, based on 1 article reviews
    diffusion pulse sequence bppled - by Bioz Stars, 2026-07
    97/100 stars
      Buy from Supplier

    86
    Resonance Technology long echo time low diffusion weighted magnetic resonance sequence technology
    Schematic diagram of the analytical procedure for <t>the</t> <t>motion‐compensated</t> diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.
    Long Echo Time Low Diffusion Weighted Magnetic Resonance Sequence Technology, supplied by Resonance Technology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/us12484783-35-21-59?v=Resonance+Technology
    Average 86 stars, based on 1 article reviews
    long echo time low diffusion weighted magnetic resonance sequence technology - by Bioz Stars, 2026-07
    86/100 stars
      Buy from Supplier

    86
    Resonance Technology diffusion tensor magnetic resonance technology sequence
    Schematic diagram of the analytical procedure for <t>the</t> <t>motion‐compensated</t> diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.
    Diffusion Tensor Magnetic Resonance Technology Sequence, supplied by Resonance Technology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/us12484783-78-23-26?v=Resonance+Technology
    Average 86 stars, based on 1 article reviews
    diffusion tensor magnetic resonance technology sequence - by Bioz Stars, 2026-07
    86/100 stars
      Buy from Supplier

    97
    Bruker Corporation diffusion weighted spin echo echo planar imaging sequence
    Connectivity between the amygdala and the claustrum complex. A Coronal sections from Case F15 following a biotinylated dextran amine (BDA) injection into the basolateral amygdala complex (BLC), showing retrogradely labelled cell bodies (red) and terminal axon fields (pink) within the claustrum complex. The insular claustrum (IC) is outlined in blue; the dorsal endopiriform nucleus [dorsal (DEnD), intermediate (DEnI), and ventral (DEnV) subdivisions] in yellow. B Streamline endpoint maps derived from the population template <t>of</t> <t>diffusion-weighted</t> tractography (Marmoset Brain Mapping Atlas), showing streamline endpoints from lateral (LA), basolateral (BL), and basomedial (BM) amygdala subnuclei - claustrum streamlines in the claustrum complex. C Left: anatomical parcellation of LA, (BL, and (BM amygdala subnuclei based on T2*-weighted MRI represented in 3D space with orientation (R; right, L; left, S; superior, I; inferior). Right: distribution of BLC–claustrum streamline endpoints along the anterior–posterior (A-P) axis of the claustrum complex
    Diffusion Weighted Spin Echo Echo Planar Imaging Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pmc12602613-108-7-17?v=Bruker+Corporation
    Average 97 stars, based on 1 article reviews
    diffusion weighted spin echo echo planar imaging sequence - by Bioz Stars, 2026-07
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation 1d diffusion ordered spectroscopy dosy pulse sequence
    Connectivity between the amygdala and the claustrum complex. A Coronal sections from Case F15 following a biotinylated dextran amine (BDA) injection into the basolateral amygdala complex (BLC), showing retrogradely labelled cell bodies (red) and terminal axon fields (pink) within the claustrum complex. The insular claustrum (IC) is outlined in blue; the dorsal endopiriform nucleus [dorsal (DEnD), intermediate (DEnI), and ventral (DEnV) subdivisions] in yellow. B Streamline endpoint maps derived from the population template <t>of</t> <t>diffusion-weighted</t> tractography (Marmoset Brain Mapping Atlas), showing streamline endpoints from lateral (LA), basolateral (BL), and basomedial (BM) amygdala subnuclei - claustrum streamlines in the claustrum complex. C Left: anatomical parcellation of LA, (BL, and (BM amygdala subnuclei based on T2*-weighted MRI represented in 3D space with orientation (R; right, L; left, S; superior, I; inferior). Right: distribution of BLC–claustrum streamline endpoints along the anterior–posterior (A-P) axis of the claustrum complex
    1d Diffusion Ordered Spectroscopy Dosy Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/10__1039_slash_d5gc03785a-263-6-20?v=Bruker+Corporation
    Average 97 stars, based on 1 article reviews
    1d diffusion ordered spectroscopy dosy pulse sequence - by Bioz Stars, 2026-07
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation ledbpgp2s pulse sequence
    Connectivity between the amygdala and the claustrum complex. A Coronal sections from Case F15 following a biotinylated dextran amine (BDA) injection into the basolateral amygdala complex (BLC), showing retrogradely labelled cell bodies (red) and terminal axon fields (pink) within the claustrum complex. The insular claustrum (IC) is outlined in blue; the dorsal endopiriform nucleus [dorsal (DEnD), intermediate (DEnI), and ventral (DEnV) subdivisions] in yellow. B Streamline endpoint maps derived from the population template <t>of</t> <t>diffusion-weighted</t> tractography (Marmoset Brain Mapping Atlas), showing streamline endpoints from lateral (LA), basolateral (BL), and basomedial (BM) amygdala subnuclei - claustrum streamlines in the claustrum complex. C Left: anatomical parcellation of LA, (BL, and (BM amygdala subnuclei based on T2*-weighted MRI represented in 3D space with orientation (R; right, L; left, S; superior, I; inferior). Right: distribution of BLC–claustrum streamline endpoints along the anterior–posterior (A-P) axis of the claustrum complex
    Ledbpgp2s Pulse Sequence, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pmc10436283__ja3c06258_si_001-870-36-35?v=Bruker+Corporation
    Average 97 stars, based on 1 article reviews
    ledbpgp2s pulse sequence - by Bioz Stars, 2026-07
    97/100 stars
      Buy from Supplier

    90
    Siemens AG diffusion sequence
    Connectivity between the amygdala and the claustrum complex. A Coronal sections from Case F15 following a biotinylated dextran amine (BDA) injection into the basolateral amygdala complex (BLC), showing retrogradely labelled cell bodies (red) and terminal axon fields (pink) within the claustrum complex. The insular claustrum (IC) is outlined in blue; the dorsal endopiriform nucleus [dorsal (DEnD), intermediate (DEnI), and ventral (DEnV) subdivisions] in yellow. B Streamline endpoint maps derived from the population template <t>of</t> <t>diffusion-weighted</t> tractography (Marmoset Brain Mapping Atlas), showing streamline endpoints from lateral (LA), basolateral (BL), and basomedial (BM) amygdala subnuclei - claustrum streamlines in the claustrum complex. C Left: anatomical parcellation of LA, (BL, and (BM amygdala subnuclei based on T2*-weighted MRI represented in 3D space with orientation (R; right, L; left, S; superior, I; inferior). Right: distribution of BLC–claustrum streamline endpoints along the anterior–posterior (A-P) axis of the claustrum complex
    Diffusion Sequence, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/diffusion+sequence/pm40500888-70-10-10?v=Siemens+AG
    Average 90 stars, based on 1 article reviews
    diffusion sequence - by Bioz Stars, 2026-07
    90/100 stars
      Buy from Supplier

    Image Search Results


    Schematic diagram of the analytical procedure for the motion‐compensated diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.

    Journal: Magnetic Resonance in Medicine

    Article Title: Motion‐Compensated Diffusion Imaging With Phase‐Contrast for Robust Quantification of Regional Cerebral Blood Flow

    doi: 10.1002/mrm.70324

    Figure Lengend Snippet: Schematic diagram of the analytical procedure for the motion‐compensated diffusion imaging with phase‐contrast (MC‐DIP). (A) Data acquisition: Diffusion‐weighted imaging (DWI) with multiple b ‐values is acquired using three gradient schemes (2nd‐MC, 1st‐MC, and non‐MC), along with phase‐contrast (PC) MRI of the internal carotid arteries (ICAs) and vertebral arteries (VAs). (B) Biexponential diffusion analysis: The DWI data are processed using a stepwise biexponential fitting to estimate the true diffusion coefficient ( D ), perfusion‐related diffusion coefficient ( D *), and perfusion fraction ( F ), from which a relative perfusion map ( FD *) is calculated. (C) Absolute regional cerebral blood flow (rCBF) calculation: The PC‐MRI data are used to calculate total cerebral blood flow (tCBF). A conversion factor is determined by dividing tCBF by the whole‐brain sum of FD * values. The final absolute rCBF map is then generated by multiplying the FD * map by this conversion factor.

    Article Snippet: The motion‐compensated diffusion sequence used in this research was provided by Philips as part of a research agreement.

    Techniques: Diffusion-based Assay, Imaging, Generated

    Representative rCBF maps from a single subject obtained using the three different DIP schemes and the reference ASL method. The non‐MC‐DIP shows prominent artifacts (areas of artificially high signal, red). These artifacts are partially reduced with 1st‐MC and most effectively suppressed with 2nd‐MC, resulting in maps with spatial distribution and contrast comparable to the ASL reference. rCBF, regional cerebral blood flow; MC‐DIP, motion‐compensated diffusion imaging with phase‐contrast; ASL, arterial spin labeling.

    Journal: Magnetic Resonance in Medicine

    Article Title: Motion‐Compensated Diffusion Imaging With Phase‐Contrast for Robust Quantification of Regional Cerebral Blood Flow

    doi: 10.1002/mrm.70324

    Figure Lengend Snippet: Representative rCBF maps from a single subject obtained using the three different DIP schemes and the reference ASL method. The non‐MC‐DIP shows prominent artifacts (areas of artificially high signal, red). These artifacts are partially reduced with 1st‐MC and most effectively suppressed with 2nd‐MC, resulting in maps with spatial distribution and contrast comparable to the ASL reference. rCBF, regional cerebral blood flow; MC‐DIP, motion‐compensated diffusion imaging with phase‐contrast; ASL, arterial spin labeling.

    Article Snippet: The motion‐compensated diffusion sequence used in this research was provided by Philips as part of a research agreement.

    Techniques: Diffusion-based Assay, Imaging, Labeling

    Comparison of biexponential fitting accuracy, as measured by the normalized root mean squared error (nRMSE), for (A) gray matter (GM) and (B) white matter (WM). The boxplots compare the second‐order motion‐compensated (2nd‐MC), first‐order motion‐compensated (1st‐MC), and non‐compensated (non‐MC) schemes. In GM, both the 1st‐MC and 2nd‐MC schemes were superior to the non‐MC scheme. In WM, however, only the 2nd‐MC scheme significantly reduced the fitting error compared with both other methods.

    Journal: Magnetic Resonance in Medicine

    Article Title: Motion‐Compensated Diffusion Imaging With Phase‐Contrast for Robust Quantification of Regional Cerebral Blood Flow

    doi: 10.1002/mrm.70324

    Figure Lengend Snippet: Comparison of biexponential fitting accuracy, as measured by the normalized root mean squared error (nRMSE), for (A) gray matter (GM) and (B) white matter (WM). The boxplots compare the second‐order motion‐compensated (2nd‐MC), first‐order motion‐compensated (1st‐MC), and non‐compensated (non‐MC) schemes. In GM, both the 1st‐MC and 2nd‐MC schemes were superior to the non‐MC scheme. In WM, however, only the 2nd‐MC scheme significantly reduced the fitting error compared with both other methods.

    Article Snippet: The motion‐compensated diffusion sequence used in this research was provided by Philips as part of a research agreement.

    Techniques: Comparison

    Scatter plots showing the correlation between DIP‐ and ASL‐derived rCBF in gray matter (GM; top row, A–C) and white matter (WM; bottom row, D–F). Each data point represents the mean rCBF value for each subject ( n = 11). The plots correspond to the second‐order motion‐compensated (2nd‐MC; A, D), first‐order motion‐compensated (1st‐MC; B, E), and non‐compensated (non‐MC; C, F) schemes. Spearman's correlation coefficients ( ρ ) and p values are shown. While all schemes correlated with ASL in GM, only the 2nd‐MC scheme established a significant correlation in WM. DIP, diffusion imaging with phase‐contrast; ASL, arterial spin labeling; rCBF, regional cerebral blood flow.

    Journal: Magnetic Resonance in Medicine

    Article Title: Motion‐Compensated Diffusion Imaging With Phase‐Contrast for Robust Quantification of Regional Cerebral Blood Flow

    doi: 10.1002/mrm.70324

    Figure Lengend Snippet: Scatter plots showing the correlation between DIP‐ and ASL‐derived rCBF in gray matter (GM; top row, A–C) and white matter (WM; bottom row, D–F). Each data point represents the mean rCBF value for each subject ( n = 11). The plots correspond to the second‐order motion‐compensated (2nd‐MC; A, D), first‐order motion‐compensated (1st‐MC; B, E), and non‐compensated (non‐MC; C, F) schemes. Spearman's correlation coefficients ( ρ ) and p values are shown. While all schemes correlated with ASL in GM, only the 2nd‐MC scheme established a significant correlation in WM. DIP, diffusion imaging with phase‐contrast; ASL, arterial spin labeling; rCBF, regional cerebral blood flow.

    Article Snippet: The motion‐compensated diffusion sequence used in this research was provided by Philips as part of a research agreement.

    Techniques: Derivative Assay, Diffusion-based Assay, Imaging, Labeling

    Connectivity between the amygdala and the claustrum complex. A Coronal sections from Case F15 following a biotinylated dextran amine (BDA) injection into the basolateral amygdala complex (BLC), showing retrogradely labelled cell bodies (red) and terminal axon fields (pink) within the claustrum complex. The insular claustrum (IC) is outlined in blue; the dorsal endopiriform nucleus [dorsal (DEnD), intermediate (DEnI), and ventral (DEnV) subdivisions] in yellow. B Streamline endpoint maps derived from the population template of diffusion-weighted tractography (Marmoset Brain Mapping Atlas), showing streamline endpoints from lateral (LA), basolateral (BL), and basomedial (BM) amygdala subnuclei - claustrum streamlines in the claustrum complex. C Left: anatomical parcellation of LA, (BL, and (BM amygdala subnuclei based on T2*-weighted MRI represented in 3D space with orientation (R; right, L; left, S; superior, I; inferior). Right: distribution of BLC–claustrum streamline endpoints along the anterior–posterior (A-P) axis of the claustrum complex

    Journal: Brain Structure & Function

    Article Title: Topographic organisation of the claustrum–amygdala–prefrontal circuitry in the common marmoset ( Callithrix jacchus )

    doi: 10.1007/s00429-025-03026-z

    Figure Lengend Snippet: Connectivity between the amygdala and the claustrum complex. A Coronal sections from Case F15 following a biotinylated dextran amine (BDA) injection into the basolateral amygdala complex (BLC), showing retrogradely labelled cell bodies (red) and terminal axon fields (pink) within the claustrum complex. The insular claustrum (IC) is outlined in blue; the dorsal endopiriform nucleus [dorsal (DEnD), intermediate (DEnI), and ventral (DEnV) subdivisions] in yellow. B Streamline endpoint maps derived from the population template of diffusion-weighted tractography (Marmoset Brain Mapping Atlas), showing streamline endpoints from lateral (LA), basolateral (BL), and basomedial (BM) amygdala subnuclei - claustrum streamlines in the claustrum complex. C Left: anatomical parcellation of LA, (BL, and (BM amygdala subnuclei based on T2*-weighted MRI represented in 3D space with orientation (R; right, L; left, S; superior, I; inferior). Right: distribution of BLC–claustrum streamline endpoints along the anterior–posterior (A-P) axis of the claustrum complex

    Article Snippet: The marmosets were scanned in a two-dimensional diffusion-weighted spin-echo echo-planar imaging sequence on a 7T horizontal MRI (Bruker, Billerica, USA) equipped with a 30-mm quadrature coil and a 15 cm customized gradient set capable of 450 mT/m gradient strength.

    Techniques: Injection, Derivative Assay, Diffusion-based Assay