1) Product Images from "Usefulness of multi-labelling artificial intelligence in detecting rhythm disorders and acute ST-elevation myocardial infarction on 12-lead electrocardiogram"
Article Title: Usefulness of multi-labelling artificial intelligence in detecting rhythm disorders and acute ST-elevation myocardial infarction on 12-lead electrocardiogram
Journal: European Heart Journal. Digital Health
doi: 10.1093/ehjdh/ztab029
Figure Legend Snippet: Data collection and labelling. In total, 72 647 12-lead electrocardiograms were retrospectively retrieved. Electrocardiograms with duplicate data ( n = 3111), incomplete information of age or age less than 18 years old ( n = 1673), absence of definite diagnosis ( n = 6759), and those not performed at China Medical University Hospital ( n = 567) were excluded. The remaining 60 537 electrocardiogram signals from 35 981 patients were included in this study.
Techniques Used:
Figure 2 . " title="... physicians, and the commercial algorithm correctly classified the electrocardiogram as second degree AV block and acute STEMI, ..." property="contentUrl" width="100%" height="100%"/>
Figure Legend Snippet: Two representative electrocardiograms in the external testing. ( A ) The long short-term memory model, all of the four cardiologists, one of the three emergency physicians, and the commercial algorithm correctly classified the electrocardiogram as second degree AV block and acute STEMI, whereas two emergency physicians and all of the three internists annotated either second degree AV block or ST-elevation myocardial infarction but not both for this electrocardiogram. ( B ) The long short-term memory model correctly classified the electrocardiogram as BIGEMINY and first degree AV block, while most doctors (8 of the 10 physicians) and the commercial algorithm only annotated BIGEMINY but not first degree AV block. Abbreviations for the electrocardiogram diagnoses as in
Techniques Used: Blocking Assay
Figure 2 . Only the four important classes, discussed in the main text are shown here, the rest was presented in Supplementary material online, Figure S1 . " title="... long short-term memory; MR, internists; abbreviations for the electrocardiogram diagnoses are as in Figure Legend Snippet: Performance of the long short-term memory model and different groups of board-certified doctors in detecting acute ST-elevation myocardial infarction and different heart rhythms. These are the accuracies and receiver operating characteristic curves in detecting ( A ) ST-elevation myocardial infarction ( B ) atrial fibrillation ( C ) complete heart block ( D ) paroxysmal supraventricular tachycardia of our artificial intelligence model and the results of a commercial algorithm and different groups of doctors in the comparative external tests. The orange line was the receiver operating characteristic curve of the long short-term memory model. The different colour points represent different groups of board-certified doctors. AI, artificial intelligence; CV, cardiologists; ER, emergency physicians; LSTM, long short-term memory; MR, internists; abbreviations for the electrocardiogram diagnoses are as in
Techniques Used: Blocking Assay
Figure Legend Snippet: The representative ST-elevation myocardial infarction electrocardiogram images of false negative cases missed by humans and the computer in the external test. ( A ) The artificial intelligence model correctly annotated ST-elevation myocardial infarction, whereas one of the four cardiologists labelled ‘Not STEMI’ resulting in a false negative annotation. ( B ) All the four cardiologists correctly diagnosed ST-elevation myocardial infarction, while the artificial intelligence model annotated ‘Not STEMI’ and it was counted as a false negative.
Techniques Used:
Related Articles
Electrophoresis:Article Title: MAPKAP Kinase-2 phosphorylation of PABPC1 controls its interaction with 14-3-3 proteins after DNA damage: A combined kinase and protein array approach Article Snippet: .. For two-dimensional electrophoresis, immunoprecipitations from whole cell extracts were suspended in 100 μL of focusing buffer (8 M urea, 2 M thiourea, 4% CHAPS, 15 mg/mL DTT, 2% ampholytes) uploaded onto pre-hydrated 7-cm Concentration Assay:Article Title: Gate Engineered Ferroelectric Junctionless BioFET for Label-Free Detection of Biomolecules Article Snippet: .. Dielectric constant (ε) SVth SIon/Ioff SSS FJBioFET GE-FJBioFET % improvement FJBioFET GE-FJBioFET % improvement FJBioFET GE-FJBioFET % improvement Biotin 0.00633 0.00949 50% 0.1066 0.18488 73.4% 0.01587 0.03333 110% Centrifugation:Article Title: Biosynthesis, Characterization, and Antifungal Activity of Novel Trimetallic Copper Oxide–Selenium–Zinc Oxide Nanoparticles against Some Mucorales Fungi Article Snippet: .. After removing the fungus’ Filtration:Article Title: Biosynthesis, Characterization, and Antifungal Activity of Novel Trimetallic Copper Oxide–Selenium–Zinc Oxide Nanoparticles against Some Mucorales Fungi Article Snippet: .. After removing the fungus’ Imaging:Article Title: Ultra-high b-Value DWI in predicting progression risk of locally advanced rectal cancer: a comparative study with routine DWI Article Snippet: .. All patients received coronal and sagittal T2WI (TR/TE = 7355/136 ms), axial FRFSE T2WI (TR/TE = 5964/130 ms) with small FOV (220 × 220 mm), Sequencing:Article Title: Ultra-high b-Value DWI in predicting progression risk of locally advanced rectal cancer: a comparative study with routine DWI Article Snippet: .. All patients received coronal and sagittal T2WI (TR/TE = 7355/136 ms), axial FRFSE T2WI (TR/TE = 5964/130 ms) with small FOV (220 × 220 mm), Article Title: Prospective comparison of [ 18 F]AlF-NOTA-octreotide PET/MRI to [ 68 Ga]Ga-DOTATATE PET/CT in neuroendocrine tumor patients Article Snippet: PET acquisition, reconstruction, and post-reconstruction filtering parameters for the GE Signa PET/MRI were identical to the GE Discovery MI 4-ring PET/CT. .. The MRI sequences obtained concurrently with PET were: (i) Coronal T2-weighted SSFSE, Magnetic Resonance Imaging:Article Title: Prospective comparison of [ 18 F]AlF-NOTA-octreotide PET/MRI to [ 68 Ga]Ga-DOTATATE PET/CT in neuroendocrine tumor patients Article Snippet: PET acquisition, reconstruction, and post-reconstruction filtering parameters for the GE Signa PET/MRI were identical to the GE Discovery MI 4-ring PET/CT. .. The MRI sequences obtained concurrently with PET were: (i) Coronal T2-weighted SSFSE, Positron Emission Tomography:Article Title: Prospective comparison of [ 18 F]AlF-NOTA-octreotide PET/MRI to [ 68 Ga]Ga-DOTATATE PET/CT in neuroendocrine tumor patients Article Snippet: PET acquisition, reconstruction, and post-reconstruction filtering parameters for the GE Signa PET/MRI were identical to the GE Discovery MI 4-ring PET/CT. .. The MRI sequences obtained concurrently with PET were: (i) Coronal T2-weighted SSFSE, Sonication:Article Title: Vibrio MARTX toxin processing and degradation of cellular Rab GTPases by the cytotoxic effector Makes Caterpillars Floppy Article Snippet: Cells were harvested by centrifugation, resuspended in Buffer A+ (10 mM Tris-HCl pH 8.3, 500 mM NaCl, 10% glycerol, 0.1 % IGEPAL® CA-630 (MilliporeSigma I3021) and protease inhibitor tablets), and frozen at -20°C. .. Cells were then thawed, sonicated for 20 minutes at 40% amplitude (pulse 5 seconds on and 10 seconds off), and centrifuged. aMCF CA was then purified from the supernatant using the AKTA protein purification system through a Ni-NTA HisTrap affinity column (GE Healthcare GE17-5248-02) with loading buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, 1 mM Tris (2-carboxyethyl) phosphine (TCEP)), washing buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, and 25 mM imidazole), and Purification:Article Title: Vibrio MARTX toxin processing and degradation of cellular Rab GTPases by the cytotoxic effector Makes Caterpillars Floppy Article Snippet: Cells were harvested by centrifugation, resuspended in Buffer A+ (10 mM Tris-HCl pH 8.3, 500 mM NaCl, 10% glycerol, 0.1 % IGEPAL® CA-630 (MilliporeSigma I3021) and protease inhibitor tablets), and frozen at -20°C. .. Cells were then thawed, sonicated for 20 minutes at 40% amplitude (pulse 5 seconds on and 10 seconds off), and centrifuged. aMCF CA was then purified from the supernatant using the AKTA protein purification system through a Ni-NTA HisTrap affinity column (GE Healthcare GE17-5248-02) with loading buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, 1 mM Tris (2-carboxyethyl) phosphine (TCEP)), washing buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, and 25 mM imidazole), and Protein Purification:Article Title: Vibrio MARTX toxin processing and degradation of cellular Rab GTPases by the cytotoxic effector Makes Caterpillars Floppy Article Snippet: Cells were harvested by centrifugation, resuspended in Buffer A+ (10 mM Tris-HCl pH 8.3, 500 mM NaCl, 10% glycerol, 0.1 % IGEPAL® CA-630 (MilliporeSigma I3021) and protease inhibitor tablets), and frozen at -20°C. .. Cells were then thawed, sonicated for 20 minutes at 40% amplitude (pulse 5 seconds on and 10 seconds off), and centrifuged. aMCF CA was then purified from the supernatant using the AKTA protein purification system through a Ni-NTA HisTrap affinity column (GE Healthcare GE17-5248-02) with loading buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, 1 mM Tris (2-carboxyethyl) phosphine (TCEP)), washing buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, and 25 mM imidazole), and Affinity Column:Article Title: Vibrio MARTX toxin processing and degradation of cellular Rab GTPases by the cytotoxic effector Makes Caterpillars Floppy Article Snippet: Cells were harvested by centrifugation, resuspended in Buffer A+ (10 mM Tris-HCl pH 8.3, 500 mM NaCl, 10% glycerol, 0.1 % IGEPAL® CA-630 (MilliporeSigma I3021) and protease inhibitor tablets), and frozen at -20°C. .. Cells were then thawed, sonicated for 20 minutes at 40% amplitude (pulse 5 seconds on and 10 seconds off), and centrifuged. aMCF CA was then purified from the supernatant using the AKTA protein purification system through a Ni-NTA HisTrap affinity column (GE Healthcare GE17-5248-02) with loading buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, 1 mM Tris (2-carboxyethyl) phosphine (TCEP)), washing buffer (10 mM Tris-HCl pH 8.5, 500 mM NaCl, and 25 mM imidazole), and |