cometchips (Trevigen)
Structured Review

Cometchips, supplied by Trevigen, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cometchip+assays/cometchips/pmc07568917-217-14-34
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Applications of CometChip for Environmental Health Studies"
Article Title: Applications of CometChip for Environmental Health Studies
Journal: Chemical research in toxicology
doi: 10.1021/acs.chemrestox.9b00393
Figure Legend Snippet: CometChip protocol involves loading cells into microwells, removing excess cells, and trapping cells with low melting point agarose. Shown here, cells are treated after being loaded into the CometChip. Cells can also be treated prior to loading into the CometChip (not shown).
Techniques Used:
Figure Legend Snippet: At the base of each macrowell on a 96-well plate are ~300 microwells in a grid. Pictured here are microwells that are ~40 μm in diameter and spaced 240 μm apart. Cells are loaded into each macrowell, and they settle into the microwells over time. Loading efficiency can be checked using a microscope by visualizing a grid of loaded microwells among the off-grid/excess cells (examples of loaded wells are marked by the blue arrows). Following the wash step, excess cells are removed, leaving behind an array of patterned cells. For these images, 40,000 TK6 cells were added to each macrowell in a volume of 80 μL. Cells remain trapped in wells following 20 min of loading time. Note that loading time can be optimized for different cell types, but can be as low as 5 min.
Techniques Used: Microscopy
Related Articles
other:Article Title: Applications of CometChip for Environmental Health Studies Article Snippet: In general, we have observed that smaller cells are trapped more efficiently by smaller diameter microwells, and the minimum microwell size possible should be selected for a cell type. (Note that CometChips sold by Agarose Gel Electrophoresis:Article Title: Adverse Outcome Pathway‐Informed Integrated Testing to Identify Chemicals Causing Genotoxicity Through Oxidative DNA Damage: Case Study on 4‐Nitroquinoline 1‐Oxide Article Snippet: High‐throughput single‐cell gel electrophoresis, that is, the CometChip assay, was conducted using the Trevigen CometChip 96‐well system (Trevigen, Maryland, United States) with and without the formamidopyrimidine DNA glycosylase (Fpg) enzyme modification to measure oxidative DNA damage and DNA strand breaks, respectively, as per the manufacturer's instructions. .. Single Cell:Article Title: Adverse Outcome Pathway‐Informed Integrated Testing to Identify Chemicals Causing Genotoxicity Through Oxidative DNA Damage: Case Study on 4‐Nitroquinoline 1‐Oxide Article Snippet: High‐throughput single‐cell gel electrophoresis, that is, the CometChip assay, was conducted using the Trevigen CometChip 96‐well system (Trevigen, Maryland, United States) with and without the formamidopyrimidine DNA glycosylase (Fpg) enzyme modification to measure oxidative DNA damage and DNA strand breaks, respectively, as per the manufacturer's instructions. .. Saline:Article Title: Adverse Outcome Pathway‐Informed Integrated Testing to Identify Chemicals Causing Genotoxicity Through Oxidative DNA Damage: Case Study on 4‐Nitroquinoline 1‐Oxide Article Snippet: High‐throughput single‐cell gel electrophoresis, that is, the CometChip assay, was conducted using the Trevigen CometChip 96‐well system (Trevigen, Maryland, United States) with and without the formamidopyrimidine DNA glycosylase (Fpg) enzyme modification to measure oxidative DNA damage and DNA strand breaks, respectively, as per the manufacturer's instructions. .. |