Review



whole blood column kit  (Miltenyi Biotec)


Bioz Verified Symbol Miltenyi Biotec is a verified supplier
Bioz Manufacturer Symbol Miltenyi Biotec manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    Miltenyi Biotec whole blood column kit
    Comparison of Aspergillus -induced cytokine release in patients with Aspergillus -associated lung pathologies and other chronic lung diseases. WB from 9 patients with Aspergillus -associated lung pathologies (2 CF with A. fumigatus sensitization, 3 ABPA, and 4 CPA) and a control group of 5 patients with other chronic lung diseases was stimulated with AfuLy or Aspf4 using the RPMI-supplemented, α-CD28-, and α-CD49d-containing stimulation tubes, as described in the Materials and Methods Section. Cytokine concentrations in plasma supernatants were quantified using a 21-plex Luminex assay. ( a , b ) Heat maps indicating median background-adjusted cytokine concentrations in the ABPA/CF/CPA patient cohort “A” and control cohort “C” depending on the antigen used for stimulation. The numeric value in the MMR <t>column</t> represents the median-to-median ratio between the two cohorts, with values > 1.0 indicating greater median cytokine concentrations in the ABPA/CF/CPA cohort. Δ denotes infinite median-to-median ratios (median = 0 pg/mL in the control cohort). ◊ denotes undefined median-to-median ratios (median = 0 pg/mL in both cohorts). ( c , d ) Heat maps summarizing individual cytokine response to AfuLy in all 14 patients. ( e ) Comparison of individual AfuLy-induced concentrations of selected T-helper cell signature cytokines. Medians and interquartile ranges for patients with ABPA/CF/CPA (“A”, red) and controls (“C”, grey) are indicated by black bars and colored boxes, respectively. Two-sided Mann–Whitney U test. Abbreviations: AfuLy = A. fumigatus mycelial lysate, ABPA = allergic bronchopulmonary aspergillosis, CF = cystic fibrosis, CPA = chronic pulmonary aspergillosis, Fractalk. = fractalkine, WB = <t>whole</t> <t>blood.</t>
    Whole Blood Column Kit, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 93/100, based on 54 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/Whole+Blood+Column+Kit/pmc08230040-54-1-5
    Average 93 stars, based on 54 article reviews
    whole blood column kit - by Bioz Stars, 2026-11
    93/100 stars

    Images

    1) Product Images from "Development of a Simple and Robust Whole Blood Assay with Dual Co-Stimulation to Quantify the Release of T-Cellular Signature Cytokines in Response to Aspergillus fumigatus Antigens"

    Article Title: Development of a Simple and Robust Whole Blood Assay with Dual Co-Stimulation to Quantify the Release of T-Cellular Signature Cytokines in Response to Aspergillus fumigatus Antigens

    Journal: Journal of Fungi

    doi: 10.3390/jof7060462

    Comparison of Aspergillus -induced cytokine release in patients with Aspergillus -associated lung pathologies and other chronic lung diseases. WB from 9 patients with Aspergillus -associated lung pathologies (2 CF with A. fumigatus sensitization, 3 ABPA, and 4 CPA) and a control group of 5 patients with other chronic lung diseases was stimulated with AfuLy or Aspf4 using the RPMI-supplemented, α-CD28-, and α-CD49d-containing stimulation tubes, as described in the Materials and Methods Section. Cytokine concentrations in plasma supernatants were quantified using a 21-plex Luminex assay. ( a , b ) Heat maps indicating median background-adjusted cytokine concentrations in the ABPA/CF/CPA patient cohort “A” and control cohort “C” depending on the antigen used for stimulation. The numeric value in the MMR column represents the median-to-median ratio between the two cohorts, with values > 1.0 indicating greater median cytokine concentrations in the ABPA/CF/CPA cohort. Δ denotes infinite median-to-median ratios (median = 0 pg/mL in the control cohort). ◊ denotes undefined median-to-median ratios (median = 0 pg/mL in both cohorts). ( c , d ) Heat maps summarizing individual cytokine response to AfuLy in all 14 patients. ( e ) Comparison of individual AfuLy-induced concentrations of selected T-helper cell signature cytokines. Medians and interquartile ranges for patients with ABPA/CF/CPA (“A”, red) and controls (“C”, grey) are indicated by black bars and colored boxes, respectively. Two-sided Mann–Whitney U test. Abbreviations: AfuLy = A. fumigatus mycelial lysate, ABPA = allergic bronchopulmonary aspergillosis, CF = cystic fibrosis, CPA = chronic pulmonary aspergillosis, Fractalk. = fractalkine, WB = whole blood.
    Figure Legend Snippet: Comparison of Aspergillus -induced cytokine release in patients with Aspergillus -associated lung pathologies and other chronic lung diseases. WB from 9 patients with Aspergillus -associated lung pathologies (2 CF with A. fumigatus sensitization, 3 ABPA, and 4 CPA) and a control group of 5 patients with other chronic lung diseases was stimulated with AfuLy or Aspf4 using the RPMI-supplemented, α-CD28-, and α-CD49d-containing stimulation tubes, as described in the Materials and Methods Section. Cytokine concentrations in plasma supernatants were quantified using a 21-plex Luminex assay. ( a , b ) Heat maps indicating median background-adjusted cytokine concentrations in the ABPA/CF/CPA patient cohort “A” and control cohort “C” depending on the antigen used for stimulation. The numeric value in the MMR column represents the median-to-median ratio between the two cohorts, with values > 1.0 indicating greater median cytokine concentrations in the ABPA/CF/CPA cohort. Δ denotes infinite median-to-median ratios (median = 0 pg/mL in the control cohort). ◊ denotes undefined median-to-median ratios (median = 0 pg/mL in both cohorts). ( c , d ) Heat maps summarizing individual cytokine response to AfuLy in all 14 patients. ( e ) Comparison of individual AfuLy-induced concentrations of selected T-helper cell signature cytokines. Medians and interquartile ranges for patients with ABPA/CF/CPA (“A”, red) and controls (“C”, grey) are indicated by black bars and colored boxes, respectively. Two-sided Mann–Whitney U test. Abbreviations: AfuLy = A. fumigatus mycelial lysate, ABPA = allergic bronchopulmonary aspergillosis, CF = cystic fibrosis, CPA = chronic pulmonary aspergillosis, Fractalk. = fractalkine, WB = whole blood.

    Techniques Used: Comparison, Control, Clinical Proteomics, Luminex, MANN-WHITNEY

    Related Articles

    Sedimentation:

    Article Title: Dual targeting of G9a and DNMTs induces antitumor effects in multiple myeloma
    Article Snippet: .. Mononuclear cells were separated by Ficoll-Paque Premium density sedimentation (Amersham Biosciences, Little Chalfont, United Kingdom) and subjected to CD138 immunomagnetic purification by Whole Blood Column Kit (magnetic activated cell sorting, Miltenyi Biotec, Paris, France), according to the manufacturer’s protocols. ..

    Purification:

    Article Title: Dual targeting of G9a and DNMTs induces antitumor effects in multiple myeloma
    Article Snippet: .. Mononuclear cells were separated by Ficoll-Paque Premium density sedimentation (Amersham Biosciences, Little Chalfont, United Kingdom) and subjected to CD138 immunomagnetic purification by Whole Blood Column Kit (magnetic activated cell sorting, Miltenyi Biotec, Paris, France), according to the manufacturer’s protocols. ..

    Magnetic Cell Separation:

    Article Title: Dual targeting of G9a and DNMTs induces antitumor effects in multiple myeloma
    Article Snippet: .. Mononuclear cells were separated by Ficoll-Paque Premium density sedimentation (Amersham Biosciences, Little Chalfont, United Kingdom) and subjected to CD138 immunomagnetic purification by Whole Blood Column Kit (magnetic activated cell sorting, Miltenyi Biotec, Paris, France), according to the manufacturer’s protocols. ..

    Article Title: Riboflavin photochemical therapy triggered PANoptosis by inducing mitochondrial damage in circulating colorectal cancer cells.
    Article Snippet: The pelleted PBMCs were resuspended in complete RPMI-1640 medium supplemented with 10 % fetal bovine serum, 1 % penicillin/streptomycin, 0.1 % β-mercaptoethanol (Gibco), and 10 ng/mL recombinant human IL-2 (#I2644, Sigma). .. Whole Blood CD326 (EpCAM) MicroBeads, human (#130-109-828), Whole Blood Column Kit (#130-093-545), LS Separation Columns (#130-122-729), Auto MACS Rinsing Solution (#130-091-222), and MACS BSA Stock Solution (#130-091-376) was purchased from Miltenyi Biotec. .. Briefly, 50 μL of Straight From Whole Blood CD326 MicroBeads were added to whole blood, thoroughly mixed, and incubated for 30 min at 2–8 ◦C.



    Similar Products

    99
    Miltenyi Biotec ls columns
    Ls Columns, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/LS+Columns/custom%40130-042-401%4042831169
    Average 99 stars, based on 1 article reviews
    ls columns - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    90
    Millipore glass column supelco sp-2560
    Glass Column Supelco Sp 2560, supplied by Millipore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/spb+5+capillary+column/10__22175_slash_mmb__18181-65-1-3
    Average 90 stars, based on 1 article reviews
    glass column supelco sp-2560 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Thermo Fisher scientific cyclone p 50 x column
    Scientific Cyclone P 50 X Column, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/nct02439229-13-9-7
    Average 90 stars, based on 1 article reviews
    scientific cyclone p 50 x column - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Thermo Fisher turboflow column
    Turboflow Column, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/nct02439229-11-33-35
    Average 90 stars, based on 1 article reviews
    turboflow column - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    86
    Sangon Biotech sanprep column yeast genomic dna extraction kit
    Sanprep Column Yeast Genomic Dna Extraction Kit, supplied by Sangon Biotech, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/column+dna+extraction+gel+kit+sanprep/pmc13199939-91-6-13
    Average 86 stars, based on 1 article reviews
    sanprep column yeast genomic dna extraction kit - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    99
    YMC America ymc triart c18 column
    Ymc Triart C18 Column, supplied by YMC America, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/YMC-Triart+C18/pmc13123502-92-8-8
    Average 99 stars, based on 1 article reviews
    ymc triart c18 column - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    86
    Kromat Corporation hp 5 column
    Hp 5 Column, supplied by Kromat Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/pmc13279033-70-12-22
    Average 86 stars, based on 1 article reviews
    hp 5 column - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Hichrom Limited pre column
    Pre Column, supplied by Hichrom Limited, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/column/column+pre/pmc13279920-185-37-47
    Average 86 stars, based on 1 article reviews
    pre column - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    Image Search Results