Review



cm10 proteinchiptm array kit  (Bio-Rad)


Bioz Verified Symbol Bio-Rad is a verified supplier
Bioz Manufacturer Symbol Bio-Rad manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    Bio-Rad cm10 proteinchiptm array kit
    Cm10 Proteinchiptm Array Kit, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 86 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cm10+proteinchiptm+array+kit/ProteinChip+CM10+Arrays/us08728823-193-22-26
    Average 93 stars, based on 86 article reviews
    cm10 proteinchiptm array kit - by Bioz Stars, 2026-11
    93/100 stars

    Images

    Related Articles

    other:

    Article Title: Isolation and Proteomic Analysis of Platelets by SELDI-TOF MS
    Article Snippet: We highly recommend that all binding buffers also be purchased from Bio-Rad to avoid any quality control issues that may arise from researchers preparing their own buffers.

    Article Title: Investigation of serum protein profiles in scrapie infected sheep by means of SELDI-TOF-MS and multivariate data analysis
    Article Snippet: A Weak cation exchange array (ProteinChip® CM10 Array, Bio-Rad) in combination with high stringency buffer, 50 mM HEPES pH 7.0 as binding and washing buffer was used to analyse the flow through (FT) fraction in this work.

    Article Title: Clinical decision support (CDS) for radiotherapy in prostate cancer
    Article Snippet: The chromatographic chips were part of BIORAD PROTEINCHIP CM10 ARRAYS.

    Article Title: Putative salivary biomarkers useful to differentiate patients with fibromyalgia.
    Article Snippet: Please cite this article as: Federica Ciregia, Camillo Giacomelli, Laura Giusti, Claudia Boldrini, Isabella Piga, Pasquale Pepe, Arianna Consensi, Sara Gori, Antonio Lucacchini, Maria R. Mazzoni, Laura Bazzichi , Putative salivary biomarkers useful to differentiate patients with fibromyalgia.. The address for the corresponding author was captured as affiliation for all authors.. Please check if appropriate.

    Article Title: Isolation and Proteomic Analysis of Platelets by SELDI-TOF MS
    Article Snippet: CM10 ProteinChip Arrays (Bio-Rad).

    Article Title: Isolation and Proteomic Analysis of Platelets by SELDI-TOF MS
    Article Snippet: There are other chemistries available such as Immobilized Metal Affinity Capture (IMAC30) and Hydrophobic (H50) and the corresponding buffers, available from Bio-Rad, should be used in conjunction with the other chemistries. list-behavior=enumeratedprefix-word=mark-type=decimalmax-label-size=0 Equilibrate CM10 ProteinChip Arrays with 150 μL CM10 Low Stringency Buffer for 5 min with vigorous shaking at room temperature.

    Binding Assay:

    Article Title: A Fragment of the LG3 Peptide of Endorepellin Is Present in the Urine of Physically Active Mining Workers: A Potential Marker of Physical Activity
    Article Snippet: The protein concentration of each urinary protein sample was determined in triplicate by bicinchoninic acid (BCA) protein assay (Pierce, Rockford, IL, USA) as per the manufacturer's instructions and adjusted to 0.42 mg/mL in binding buffer (10 mM sodium acetate (NaAc), pH 4.5). .. CM10 (weak cation exchange) ProteinChip arrays (Bio-Rad, Hercules, CA, USA) were then pre-equilibrated twice with 50-μl of binding buffer using a ProteinChip Cassette – Compatible Bioprocessor (Cat # C50-30011) (BioRad) and placed on a plate shaker for 5 min. Triplicate 35 μL sub-samples of urinary protein and a single QC replicate sample were applied to the surface of the CM10 arrays in a semi-randomised fashion to ensure that no replicate samples occupied a second spot on individual arrays. ..

    QC/EQA/Proficiency:

    Article Title: A Fragment of the LG3 Peptide of Endorepellin Is Present in the Urine of Physically Active Mining Workers: A Potential Marker of Physical Activity
    Article Snippet: The protein concentration of each urinary protein sample was determined in triplicate by bicinchoninic acid (BCA) protein assay (Pierce, Rockford, IL, USA) as per the manufacturer's instructions and adjusted to 0.42 mg/mL in binding buffer (10 mM sodium acetate (NaAc), pH 4.5). .. CM10 (weak cation exchange) ProteinChip arrays (Bio-Rad, Hercules, CA, USA) were then pre-equilibrated twice with 50-μl of binding buffer using a ProteinChip Cassette – Compatible Bioprocessor (Cat # C50-30011) (BioRad) and placed on a plate shaker for 5 min. Triplicate 35 μL sub-samples of urinary protein and a single QC replicate sample were applied to the surface of the CM10 arrays in a semi-randomised fashion to ensure that no replicate samples occupied a second spot on individual arrays. ..

    Mass Spectrometry:

    Article Title: Functionalized cerium oxide nanoparticles mitigate the oxidative stress and pro-inflammatory activity associated to the portal vein endothelium of cirrhotic rats
    Article Snippet: .. Protein profiling was performed by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) using the eight-spot format CM10 ProteinChip arrays (Bio-Rad, Hercules, CA, USA). ..



    Similar Products

    93
    Bio-Rad cm10 proteinchiptm array kit
    Cm10 Proteinchiptm Array Kit, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cm10+proteinchiptm+array+kit/ProteinChip+CM10+Arrays/us08728823-193-22-26
    Average 93 stars, based on 1 article reviews
    cm10 proteinchiptm array kit - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    Image Search Results