Review



sample jet sample changer  (Bruker Corporation)


Bioz Verified Symbol Bruker Corporation is a verified supplier
Bioz Manufacturer Symbol Bruker Corporation manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 97

    Structured Review

    Bruker Corporation sample jet sample changer
    Sample Jet Sample Changer, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 919 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/SampleJet/pmc12420700-39-10-14
    Average 97 stars, based on 919 article reviews
    sample jet sample changer - by Bioz Stars, 2026-11
    97/100 stars

    Images

    Related Articles

    other:

    Article Title: Identification of KLHL12 Ligands Using Fragment-Based Methods.
    Article Snippet: IRDye Secondary antibodies were purchased from LI-COR.

    Article Title: Metabolic Phenotyping Objectively Captures Dietary Intake and Short-term Cardiovascular Disease Risk Responses Under an Inpatient Randomized Crossover Clinical Trial
    Article Snippet: Serum samples were analyzed at 300 K on a 600 MHz Bruker Avance III HD spectrometer equipped with a 5 mm BBI probe and fitted with the Bruker SampleJetTM robot cooling system set to 5 °C.

    Article Title: Roseburia inulinivorans increases muscle strength.
    Article Snippet: A Bruker SampleJet sample changer was used for sample insertion and removal.

    Article Title: Detection of Phosphite Fungicide in Persea americana Fruits Using Nuclear Magnetic Resonance (NMR) Spectroscopy at 400 and 80 MHz.
    Article Snippet: To assist in the identification of discriminatory signals of interest, additional experiments were conducted on selected samples showing analytes of interest, pure standards, and spiked standards, using a 600 MHz Bruker Avance III HD spectrometer equipped with a 5 mm BBI probe and/or an 800 MHz Bruker AvanceNeo spectrometer, equipped with a 5 mm QCI cryo-probe.

    Nuclear Magnetic Resonance:

    Article Title: Systemic Rhythmicity of Host and Bacterial Bile Acid Amidates in the Mouse
    Article Snippet: .. The one-dimensional 1 H spectra of extracts were recorded at 298 K by using a Bruker Avance NEO 600 MHz NMR spectrometer (Bruker Biospin) equipped with a 5 mm TCI cryoprobe with enhanced sensitivity for 1 H and a high-throughput Bruker SampleJet autosampler. ..

    Article Title: An NMR-Based Protocol for Profiling the Endo- and Exo-Metabolomes in Aβ 1-42 Treated Human Astrocytes from Healthy and Alzheimer’s Disease Donors
    Article Snippet: .. 1 H NMR spectra were acquired using a Bruker 600 MHz spectrometer (Bruker BioSpin GmbH, Ettlingen, Germany) operating at 600.13 MHz proton Larmor frequency equipped with a 5 mm PATXI 1 H- 13 C- 15 N and 2 H-decoupling probe including a z -axis gradient coil, an automatic tuning–matching (ATM) system and an automatic refrigerated (6 °C) sample changer (SampleJet, Bruker BioSpin). ..

    Article Title: Detection of Phosphite Fungicide in Persea americana Fruits Using Nuclear Magnetic Resonance (NMR) Spectroscopy at 400 and 80 MHz.
    Article Snippet: .. Phosphate buffer (1.5 M KH2PO4, 2 mM NaN3, 0.1% sodium trimethylsilyl propionate-[2,2,3,3-2H4] (TSP) in D2O, pH 7.4 ± 0.1), and 5 mm outer diameter SampleJet NMR tubes and regular 7 in. with the corresponding sealing caps were purchased from Bruker BioSpin GmbH & Co. KG (Ettlingen, Germany). .. with the corresponding sealing caps were purchased from Bruker BioSpin GmbH & Co. KG (Ettlingen, Germany).

    Article Title: Systemic rhythmicity of host and bacterial bile acid amidates in the mouse.
    Article Snippet: Article Systemic rhythmicity of host and bacterial bile acid amidates in the mouse

    Automatic:

    Article Title: An NMR-Based Protocol for Profiling the Endo- and Exo-Metabolomes in Aβ 1-42 Treated Human Astrocytes from Healthy and Alzheimer’s Disease Donors
    Article Snippet: .. 1 H NMR spectra were acquired using a Bruker 600 MHz spectrometer (Bruker BioSpin GmbH, Ettlingen, Germany) operating at 600.13 MHz proton Larmor frequency equipped with a 5 mm PATXI 1 H- 13 C- 15 N and 2 H-decoupling probe including a z -axis gradient coil, an automatic tuning–matching (ATM) system and an automatic refrigerated (6 °C) sample changer (SampleJet, Bruker BioSpin). ..



    Similar Products

    96
    Carl Zeiss magnification changers
    Magnification Changers, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/Optovar+1%2E6x/pm42521806-226-15-20
    Average 96 stars, based on 1 article reviews
    magnification changers - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    86
    Luigs & Neumann Feinmechanik 4 time filter changer
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    4 Time Filter Changer, supplied by Luigs & Neumann Feinmechanik, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/4+changer+filter+time/pmc13058980-113-0-4
    Average 86 stars, based on 1 article reviews
    4 time filter changer - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    99
    New England Biolabs nebase changer q5 site directed mutagenesis kit
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    Nebase Changer Q5 Site Directed Mutagenesis Kit, supplied by New England Biolabs, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/Q5+Site-Directed+Mutagenesis+Kit/bio_rxiv__64898__2026__03__26__714389-246-9-15
    Average 99 stars, based on 1 article reviews
    nebase changer q5 site directed mutagenesis kit - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    86
    Nanotherapeutics m l nanodiscs game changer nanotherapeutics
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    M L Nanodiscs Game Changer Nanotherapeutics, supplied by Nanotherapeutics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/changer+game+l+m+nanodiscs+nanotherapeutics/pm41840854-308-19-24
    Average 86 stars, based on 1 article reviews
    m l nanodiscs game changer nanotherapeutics - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    95
    Sutter Instrument Company lambda 10 2 filter changer
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    Lambda 10 2 Filter Changer, supplied by Sutter Instrument Company, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/Lambda+10-2+Filter+Wheel/bio_rxiv__64898__2026__02__06__702976-184-7-11
    Average 95 stars, based on 1 article reviews
    lambda 10 2 filter changer - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    97
    Bruker Corporation changer
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    Changer, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/SampleJet/pmc12943432-138-47-48
    Average 97 stars, based on 1 article reviews
    changer - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    97
    Bruker Corporation changer bruker samplejet
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    Changer Bruker Samplejet, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/SampleJet/bio_rxiv__64898__2025__12__19__695515-162-28-29
    Average 97 stars, based on 1 article reviews
    changer bruker samplejet - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    90
    Bruker Corporation automatic sample changer (b-acs 120)
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    Automatic Sample Changer (B Acs 120), supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/bacs+120+sample+changer/pmc12219009-68-23-23
    Average 90 stars, based on 1 article reviews
    automatic sample changer (b-acs 120) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    97
    Bruker Corporation sample jet sample changer
    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An <t>optical</t> <t>4-time</t> filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).
    Sample Jet Sample Changer, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/changer/SampleJet/pmc12420700-39-10-14
    Average 97 stars, based on 1 article reviews
    sample jet sample changer - by Bioz Stars, 2026-11
    97/100 stars
      Buy from Supplier

    Image Search Results


    Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An optical 4-time filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).

    Journal: STAR Protocols

    Article Title: Protocol for whole-cell patch-clamp recording and post hoc identification of hippocampal CA2 pyramidal neurons in adult mouse brain slices

    doi: 10.1016/j.xpro.2026.104470

    Figure Lengend Snippet: Patch-clamp recording system (A) Overview of the preparation table showing the slicer at the left, two PP beakers on ice containing sucrose solution supplied with 95% O2 and 5% CO2. At the foreground a 80 mm in diameter crystallizing dish containing sucrose solution oxygenated using 95% O2 – 5% CO2 is to receive the brain after resection. Large scissors are to remove the head and small scissors to open the skull with a caudal to nasal cut. (B) Schematic representation of the sequential cuts to prepare hemispheres. View of a mouse brain from the top. The cerebral cortex is in grey, the cerebellum in yellow and the hippocampal region in green. A first cut (1) using a scalpel is to remove the cerebellum. A second sagittal cut (2) is to separate both hemispheres. A third (3) and a fourth (4) cut are to remove a small piece of tissue at the lateral side of the hemispheres. The lateral side of the hemisphere is glued on the specimen disk. Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (C) View of the medial side of the two hemispheres in a Petri dish after sagittal cut of the whole brain. The base of the Petri dish is filled with hardened agarose. Brain tissue is lying on the agarose layer and surrounded by liquid-solid sludgy sucrose solution. Inset shows an enlarged view of the hemispheres. (D) View of the top of a mouse brain hemisphere. The brain is in gray and the hippocampus (HPC) in green. Parasagittal slices are cut starting from the medial side of the hemisphere towards the lateral side. Red dashed lines represent consecutive cuts to produce 300 μm thick slices containing the dorsal hippocampus (dorsal HPC). Three-dimensional structure of adult mouse from Brain Explorer 2 (version 2.3.5 Built 2393, Allen institute, https://brain-map.org ). (E) Cutting of brain slices in the parasagittal plane using the vibratome. View of the buffer tray containing sucrose solution with a liquid phase close to the hemispheres and a liquid-solid sludgy phase at the border of the buffer tray. (F) Magnified view of the buffer tray. Hemispheres are glued on a specimen disk. The specimen disk contains a magnet in order to be maintained at the bottom of the buffer tray. Inset shows a scheme representing a blade cutting sagittal slices. The brain is in gray and the hippocampus in green. The scheme was created in Biorender. (G) Overview of the water bath containing the storage chamber enclosing the brain slices. Tissue is maintained at a temperature of 34°C. (H) Top view of a storage chamber filled with sucrose solution. A gauze net maintains slices at ∼half-height of the beaker. A small micro filter candle supplies 95% O2 and 5% CO2 gas mixture to the solution. Very small gas bubbles are delivered by micro filter candles with a porosity of 4 corresponding to small pores. (I) Front view of the patch-clamp setup. The microscope is mounted on a table allowing movement in the two horizontal X-Y directions. Manipulators to move pipette are left and right to the recording table. An optical 4-time filter changer (Luigs&Neumann) containing magnification glasses is mounted on the top of the microscope and the digital camera (not appearing in the overview) on top of optic changer. (J) Recording chamber containing a brain slice. A water immersion objective (40X) is on top of the slice to visualize neurons. At the right a patch pipette in a pipette holder (Luigs&Neumann) with a bracket (Luigs&Neumann) surrounding the pipette holder to stabilize pipette. Inset shows the stainless steel slice hold-down flat frame with threads (Warner Instruments).

    Article Snippet: 4-time filter changer , Luigs&Neumann , Cat#200-100 200 0159-10.

    Techniques: Patch Clamp, Microscopy, Transferring, Slice Preparation