Review



cfd postprocessing software ansys-cfx-post 14.5  (ANSYS inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    ANSYS inc cfd postprocessing software ansys-cfx-post 14.5
    Cfd Postprocessing Software Ansys Cfx Post 14.5, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/cfd+postprocessing+software+cfd+post/pmc05519664-109-5-7
    Average 90 stars, based on 1 article reviews
    cfd postprocessing software ansys-cfx-post 14.5 - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    Software:

    Article Title: Surgical strategy for aortic arch reconstruction after the Norwood procedure based on numerical flow analysis.
    Article Snippet: .. The numerical results were visualized and analysed using the CFD postprocessing software, CFD Post (ANSYS Japan). ..

    Article Title: Validation of numerical simulation methods in aortic arch using 4D Flow MRI
    Article Snippet: .. The commercial CFD postprocessing software, ANSYS-CFX-Post 14.5 (ANSYS Japan, Tokyo, Japan), was used to analyze and visualize the numerical CFD results. ..

    Article Title: Early outcomes and computational fluid dynamic analyses of chimney reconstruction in the Norwood procedure†.
    Article Snippet: .. Numerical results were visualized and analysed using CFD postprocessing software (CFD Post; ANSYS Japan, Tokyo, Japan). ..

    Article Title: Adhesion properties of modified cement-retained implant prostheses: In vitro mechanical tensile experiments and computational fluid dynamics analyses.
    Article Snippet: Statement of problem.. The adhesion properties of modified cement-retained implant prostheses have not been elucidated.. Purpose.

    other:

    Article Title: Computational Fluid Dynamic Study of Nasal Respiratory Function Before and After Bimaxillary Orthognathic Surgery With Bone Trimming at the Inferior Edge of the Pyriform Aperture.
    Article Snippet: Accepted Manuscript Computational fluid dynamic study of nasal respiratory function before and after bimaxillary orthognathic surgery with bone trimming at the inferior edge of the pyriform aperture Soma Kita, DDS, Marie Oshima, PhD, Kazuo Shimazaki, DDS, PhD, Toshinori Iwai, DDS, PhD, Susumu Omura, DDS, PhD, Takashi Ono, DDS, PhD PII: S0278-2391(16)30489-X DOI: 10.1016/j.joms.2016.06.171 Reference: YJOMS 57327 To appear in: Journal of Oral and Maxillofacial Surgery Received Date: 6 February 2016 Revised Date: 10 June 2016 Accepted Date: 12 June 2016 Please cite this article as: Kita S, Oshima M, Shimazaki K, Iwai T, Omura S, Ono T, Computational fluid dynamic study of nasal respiratory function before and after bimaxillary orthognathic surgery with bone trimming at the inferior edge of the pyriform aperture, Journal of Oral and Maxillofacial Surgery (2016), doi: 10.1016/j.joms.2016.06.171.. This is a PDF file of an unedited manuscript that has been accepted for publication.. As a service to our customers we are providing this early version of the manuscript.

    Article Title: Computational fluid dynamic analysis of the nasal respiratory function before and after postero-superior repositioning of the maxilla
    Article Snippet: Imaging simulation was performed using post-processing software (CFD-Post 14.0, ANSYS, Canonsburg, PA, USA).

    Article Title: Hemodynamic consequences of a multilayer flow modulator in Aortic Dissection
    Article Snippet: The hemodynamic features including velocity distribution, flow streamlines, and wall shear stress map were analyzed using the ANSYS post processing package (CFD-Post, ANSYS v16.0, Canonsburg, PA, USA) and in-house subroutines.

    Article Title: Computational fluid dynamics study of the pharyngeal airway space before and after mandibular setback surgery in patients with mandibular prognathism.
    Article Snippet: The purpose of this study was to investigate the relationship between the pressure drop in the pharyngeal airway space (DPPAS) and the minimum crosssectional area (minCSA) of the pharyngeal airway before and after mandibular setback surgery using computational fluid dynamics, in order to prevent iatrogenic obstructive sleep apnoea.. Eleven patients with mandibular prognathism underwent bilateral sagittal split osteotomy for mandibular setback.. Three-dimensional models of the upper airway were reconstructed from preoperative and postoperative computed tomography images, and simulations were performed using computational fluid dynamics.



    Similar Products

    90
    ANSYS inc cfd post
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Cfd Post, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/cfd+post/pmc12278367-72-8-10
    Average 90 stars, based on 1 article reviews
    cfd post - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    ANSYS inc cfd-post
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Cfd Post, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/cfd+post/pm40619480-207-6-14
    Average 90 stars, based on 1 article reviews
    cfd-post - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    ANSYS inc cfd model ansys cfd-post
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Cfd Model Ansys Cfd Post, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/ansys+cfx/pm40592301-61-42-42
    Average 90 stars, based on 1 article reviews
    cfd model ansys cfd-post - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    ANSYS inc ansys cfd-post
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Ansys Cfd Post, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/ansys+cfx/pm40473879-158-8-3
    Average 90 stars, based on 1 article reviews
    ansys cfd-post - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    ANSYS inc ansys cfd post
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Ansys Cfd Post, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/ansys+cfx/10__1016_slash_j__ast__2025__110497-98-7-7
    Average 90 stars, based on 1 article reviews
    ansys cfd post - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    ANSYS inc cfd-post software
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Cfd Post Software, supplied by ANSYS inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/cfd+post/pm40428101-62-0-1
    Average 90 stars, based on 1 article reviews
    cfd-post software - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Tecplot Inc cfd-post
    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics <t>(CFD)</t> results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), <t>post-stenotic</t> dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.
    Cfd Post, supplied by Tecplot Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cfd-post/cfd+post/pm40221738-107-5-7
    Average 90 stars, based on 1 article reviews
    cfd-post - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics (CFD) results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), post-stenotic dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.

    Journal: Lab on a Chip

    Article Title: 3D modelling of pulmonary arterial stenosis and endothelial dysfunction in CTEPH †

    doi: 10.1039/d5lc00300h

    Figure Lengend Snippet: Wall shear stress in semi-circular channels simulated with water. Computational fluid dynamics (CFD) results showing wall shear stress (WSS) at the top and bottom of the semi-circular in the control (A–C), 30% stenosis (D–F), 60% stenosis (G–I) and 80% stenosis (J–L) models. Colour scales at the top of the images in (A)–(H) represent a WSS range between 0.0–2.0 Pa (0.0–20 dyn cm −2 ), while in (J and K) the scale ranges from 0.0–18.1 Pa (0.0–181 dyn cm −2 ). In (C, F, I and L) the x axis indicates the different regions of the channel: upstream (U; 7 mm), stenosis (S; 11 mm), post-stenotic dilatation (PSD; 13.5 mm), downstream 1 (D1; 18 mm) and downstream 2 (D2; 22.5 mm). All simulations were performed in CFX (Ansys, Inc.), using an inlet velocity of 60.2 mm s −1 (0.5 L h −1 ) and outlet pressure of 0.097 kPa.

    Article Snippet: All results files were post-processed and analysed in CFD POST (Ansys, Inc.).

    Techniques: Shear, Control