polymethylmethacrylate surgical simplex® p (Howmedica)
90
Structured Review
Howmedica
polymethylmethacrylate surgical simplex® p
Polymethylmethacrylate Surgical Simplex® P, supplied by Howmedica, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cemented+implants+simplex-p/polymethylmethacrylate+surgical+simplex++p/pmc08526787-52-18-22
Average 90 stars, based on 1 article reviews
Polymethylmethacrylate Surgical Simplex® P, supplied by Howmedica, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cemented+implants+simplex-p/polymethylmethacrylate+surgical+simplex++p/pmc08526787-52-18-22
Average 90 stars, based on 1 article reviews
polymethylmethacrylate surgical simplex® p - by Bioz Stars,
2026-09
90/100 stars
Images
Related Articles
other:Article Title: Modified Ventral Stabilization Using Positively Threaded Profile Pins and Polymethylmethacrylate for Atlantoaxial Instability in 49 Dogs Article Snippet: Cefazolin powder (250 mg) was mixed with a half dose of the PMMA powder (Surgical Simplex P, Howmedica, Rutherford, NJ) before mixing with the liquid monomer. Article Title: Implant design and resection length affect cemented endoprosthesis survival in proximal tibial reconstruction. Article Snippet: Endoprosthetic reconstruction of the proximal tibia continues to pose many challenges.. A retrospective analysis of 44 consecutive patients who underwent cemented proximal tibial replacement were included to investigate if patient age, surgical stage, type of implant, stem diameter, or resection length could be associated with implant failure.. Fifteen patients (34%) suffered prosthetic failure, 7 due to infection. Article Title: Femoral Stem Fracture and Successful Reimplantation Using Femoral Window Technique in Canine Cemented Total Hip Replacement: Case Report Article Snippet: Both components, i.e., cup and stem, were secured with Article Title: Repair of Chiari III malformation using cranioplasty and an occipital rotation flap: technical note and review of literature. Article Snippet: Background: Chiari III malformation (CM3) is rare among Chiari malformations (I-IV).. Its Abbreviations: CM phy; CVJ, cranioverte The authors have n source for preparation ⁎ Corresponding E-mail address: su 0090-3019/$ – see fro doi:10.1016/j.surneu.2 definition has been expanded to include caudal medullary displacement and hindbrain herniation into encephaloceles in lower occipital and high cervical regions.. Prognosis is recorded as dismal, with respect to survival and functional outcome. Article Title: Mandibular reconstruction using induced membranes with autologous cancellous bone graft and HA-betaTCP: animal model study and preliminary results in patients. Article Snippet: Providing an acceptable quality of life for patients after reconstruction of mandibular segmental defects is challenging because the surgical techniques available have limitations.. The authors evaluated two-stage mandibular reconstruction in rabbits and provide preliminary results in humans.. 21 rabbits underwent bilateral segmental mandibulectomy and the defect was filled with methylmethacrylate. Article Title: Femoral Stem Fracture and Successful Reimplantation Using Femoral Window Technique in Canine Cemented Total Hip Replacement: Case Report Article Snippet: The fractured stem was replaced with a new one, the same size (femoral stem 7.5) and secured with Injection:Article Title: Vertebroplasty combined with pedicular instrumentation. Article Snippet: Osteoporosis and cancer patients may suffer sudden severe back pain due to vertebral body osteolysis, microfractures and/or compression fractures.. These patients need immediate restabilisation of the vertebral body to eliminate the pain generator, to prevent further crushing, and to reduce the comorbidity of prolonged immobilisation.. Vertebroplasty combined with pedicular instrumentation is presented as a therapy for a selected group of such patients. Centrifugation:Article Title: Femoral component failure in canine cemented total hip replacement: a report of two cases. Article Snippet: Femoral stem fracture is reported as an uncommon late complication of cemented total hip replacement in two dogs.. In each case surgical salvage was achieved by extirpation of the proximal unstable component of the femoral stem, resulting in acceptable limb function.. To the authors’ knowledge, intramedullary femoral stem failure has not been previously reported after cemented total hip replacement in the dog. |