Review




Structured Review

nanoAnalytics gmbh cellzscope module
Cellzscope Module, supplied by nanoAnalytics gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cellzscope/cellzscope+cell+modules/pmc06503375-67-8-10
Average 90 stars, based on 1 article reviews
cellzscope module - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Effects of whey protein treatment in an in vitro intestinal cell model following oxidative stress or inflammatory challenge
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Article Title: Effect of E Cigarette Emissions on Tracheal Cells Monitored at the Air-Liquid Interface Using an Organic Electrochemical Transistor.
Article Snippet: Transepithelial Electrical Resistance Measurements: TEER measurements were performed using the cellZscope module (nanoAnalytics GmbH, Germany).

Article Title: Bovine dairy complex lipids improve in vitro measures of small intestinal epithelial barrier integrity
Article Snippet: The day prior to the TEER assay, Transwells were transferred into cellZscope cell modules (nanoAnalytics GmbH, Munster, Germany) and the baseline resistances across the cell layers were measured hourly for 24 hours using the cellZscope computer-controlled system.

Article Title: Short communication: Processed bovine colostrum milk protein concentrate increases epithelial barrier integrity of Caco-2 cell layers.
Article Snippet: The day before the TEER assay, Transwells containing the Caco-2 cell monolayers were transferred into a cellZscope cell module (nanoAnalytics GmbH, Münster, Germany), which is an automated system for measuring TEER over time (Wegener et al., 2004).

Article Title: Haem iron reshapes colonic luminal environment: impact on mucosal homeostasis and microbiome through aldehyde formation
Article Snippet: After seeding, the inserts were transferred into a cellZscope module (NanoAnalytics Münster, Germany) at 5% CO 2 and at the permissive temperature of 33 °C.

Article Title: Transepithelial permeability studies of flavan-3-ol-C-glucosides and procyanidin dimers and trimers across the Caco-2 cell monolayer.
Article Snippet: In this study the permeability of two flavanol-C-glucosides (FCglcs) and five dimeric and trimeric flavan-3-ols, namely, procyanidins (PCs), was investigated with the human colon carcinoma cell line (Caco-2) model.. These compounds can be found especially in cocoa, and they are of great interest due to their assumed beneficial health effects.. Transepithelial electrical resistance (TEER) and capacitance were measured online with a CellZscope device prior to and during the whole experiment to guarantee the maintenance of the barrier properties.

Incubation:

Article Title: Influence of Bovine Whey Protein Concentrate and Hydrolysate Preparation Methods on Motility in the Isolated Rat Distal Colon
Article Snippet: Caco-2 cells were seeded at a density of 8 × 10 4 cells/Transwell (6.5 mm, polyester, 0.4 μm pore size; Corning Incorporated, Corning, NY, USA) and grown in Medium 199 (M199; Gibco, Invitrogen Corporation, Carlsbad, CA, USA) supplemented with 10% fetal bovine serum (FBS; Gibco, Invitrogen Corporation Carlsbad, CA, USA), 1% non-essential amino acids (NEAA; MEM non-essential amino acids 100× solution; Sigma-Aldrich) and 1% penicillin–streptomycin (Pen–Strep: 10,000 units/mL penicillin G sodium salt and 10,000 μg/mL streptomycin sulfate in 0.85% saline; Gibco, Invitrogen Corporation) at 37 °C in 5% CO 2 for 15 to 19 days until they formed a differentiated monolayer. .. The day prior to the TEER assay, Transwells were transferred into cellZscope cell modules (nanoAnalytics GmbH, Münster, Germany) with M199 supplemented with 10% FBS, 1% NEAA and 1% Pen–Strep in the basal compartment and M199 supplemented with 1% NEAA in the apical compartment, and incubated (37 °C, 5% CO 2 ). ..

Article Title: Short communication: Early-lactation, but not mid-lactation, bovine lactoferrin preparation increases epithelial barrier integrity of Caco-2 cell layers.
Article Snippet: We seeded Caco-2 cells at a concentration of 8 × 104 cells/Transwell (6.5 mm, polyester, 0.4 μm pore size; Corning Inc., Corning, NY) and grown in Medium 199 (M199; Gibco, Invitrogen Corporation, Carlsbad, CA) supplemented with 10% fetal bovine serum (FBS; Gibco, Invitrogen Corporation), 1% NEAA (MEM NEAA 100× solution; Sigma-Aldrich, St. Louis, MO) and 1% penicillin-streptomycin (Pen-Strep, 10,000 units/mL penicillin G sodium salt and 10,000 μg/mL streptomycin sulfate in 0.85% saline; Gibco, Invitrogen Corporation) at 37°C in 5% CO2 for 15 to 19 d until they formed a differentiated monolayer. .. The day before the TEER assay, Transwells were transferred into cellZscope cell modules (nanoAnalytics GmbH, Münster, Germany) that had M199 supplemented with 10% FBS, 1% NEAA, and 1% Pen-Strep in the basal compartment and M199 supplemented with 1% NEAA and 1% Pen-Strep in the apical compartment, and incubated (37°C, 5% CO2). ..



Similar Products

90
nanoAnalytics gmbh cellzscope+ instrument
Cellzscope+ Instrument, supplied by nanoAnalytics gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cellzscope/cellzscope+instrument/pmc10103300__nl3c00377_si_001-30-12-14
Average 90 stars, based on 1 article reviews
cellzscope+ instrument - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
nanoAnalytics gmbh cellzscope+ equipment
Cellzscope+ Equipment, supplied by nanoAnalytics gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cellzscope/cellzscope++equipment/pmc10723066__jf3c05479_si_001-38-12-14
Average 90 stars, based on 1 article reviews
cellzscope+ equipment - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
nanoAnalytics gmbh cellzscope
Cellzscope, supplied by nanoAnalytics gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cellzscope/cellzscope/pm40644968-126-12-13
Average 90 stars, based on 1 article reviews
cellzscope - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
nanoAnalytics gmbh cellzscope -device
Transendothelial electrical resistance (TEER) monitored over time after introduction of transwell inserts to the <t>cellZscope</t> the day after seeding of mouse brain microvascular endothelial cells (mBMEC) and four days after astrocyte seeding. Presented are the mean values of n=6 inserts (continuous line) with the standard deviation (SD; dotted lines and filled area) (A) . TEER values obtained at 72h (C) and 120h (D) of incubation in the cellZscope were statistically tested with a repeated measures one-way analysis of variance (ANOVA), followed by Tukey’s test for multiple comparison (C, D) . Barrier permeability assay of inserts after 120h of incubation in the cellZscope . Presented are the values of n=3 inserts with the SD. Horizontal dotted line indicates 1% of FITC-dextran stock solution, whereas horizontal dashed line indicates 0.1% of applied FITC-dextran concentration (B) . FITC-dextran concentrations determined at 240 minutes after apical application were statistically tested with a repeated measures one-way ANOVA, followed by Tukey’s test for multiple comparison (E) . Asterisks indicate statistical significance as follows: p < 0.05*, p < 0.01**, p < 0.0001****.
Cellzscope Device, supplied by nanoAnalytics gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cellzscope/cellzscope+device/pmc12263646-72-8-15
Average 90 stars, based on 1 article reviews
cellzscope -device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
nanoAnalytics gmbh automated cellzscope equipment
Transendothelial electrical resistance (TEER) monitored over time after introduction of transwell inserts to the <t>cellZscope</t> the day after seeding of mouse brain microvascular endothelial cells (mBMEC) and four days after astrocyte seeding. Presented are the mean values of n=6 inserts (continuous line) with the standard deviation (SD; dotted lines and filled area) (A) . TEER values obtained at 72h (C) and 120h (D) of incubation in the cellZscope were statistically tested with a repeated measures one-way analysis of variance (ANOVA), followed by Tukey’s test for multiple comparison (C, D) . Barrier permeability assay of inserts after 120h of incubation in the cellZscope . Presented are the values of n=3 inserts with the SD. Horizontal dotted line indicates 1% of FITC-dextran stock solution, whereas horizontal dashed line indicates 0.1% of applied FITC-dextran concentration (B) . FITC-dextran concentrations determined at 240 minutes after apical application were statistically tested with a repeated measures one-way ANOVA, followed by Tukey’s test for multiple comparison (E) . Asterisks indicate statistical significance as follows: p < 0.05*, p < 0.01**, p < 0.0001****.
Automated Cellzscope Equipment, supplied by nanoAnalytics gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cellzscope/automated+cell+monitoring+system+cellzscope/pmc12186227-343-10-12
Average 90 stars, based on 1 article reviews
automated cellzscope equipment - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Transendothelial electrical resistance (TEER) monitored over time after introduction of transwell inserts to the cellZscope the day after seeding of mouse brain microvascular endothelial cells (mBMEC) and four days after astrocyte seeding. Presented are the mean values of n=6 inserts (continuous line) with the standard deviation (SD; dotted lines and filled area) (A) . TEER values obtained at 72h (C) and 120h (D) of incubation in the cellZscope were statistically tested with a repeated measures one-way analysis of variance (ANOVA), followed by Tukey’s test for multiple comparison (C, D) . Barrier permeability assay of inserts after 120h of incubation in the cellZscope . Presented are the values of n=3 inserts with the SD. Horizontal dotted line indicates 1% of FITC-dextran stock solution, whereas horizontal dashed line indicates 0.1% of applied FITC-dextran concentration (B) . FITC-dextran concentrations determined at 240 minutes after apical application were statistically tested with a repeated measures one-way ANOVA, followed by Tukey’s test for multiple comparison (E) . Asterisks indicate statistical significance as follows: p < 0.05*, p < 0.01**, p < 0.0001****.

Journal: Frontiers in Cellular and Infection Microbiology

Article Title: Mosquito- and tick-borne orthoflaviviruses cross an in vitro endothelial-astrocyte barrier

doi: 10.3389/fcimb.2025.1624636

Figure Lengend Snippet: Transendothelial electrical resistance (TEER) monitored over time after introduction of transwell inserts to the cellZscope the day after seeding of mouse brain microvascular endothelial cells (mBMEC) and four days after astrocyte seeding. Presented are the mean values of n=6 inserts (continuous line) with the standard deviation (SD; dotted lines and filled area) (A) . TEER values obtained at 72h (C) and 120h (D) of incubation in the cellZscope were statistically tested with a repeated measures one-way analysis of variance (ANOVA), followed by Tukey’s test for multiple comparison (C, D) . Barrier permeability assay of inserts after 120h of incubation in the cellZscope . Presented are the values of n=3 inserts with the SD. Horizontal dotted line indicates 1% of FITC-dextran stock solution, whereas horizontal dashed line indicates 0.1% of applied FITC-dextran concentration (B) . FITC-dextran concentrations determined at 240 minutes after apical application were statistically tested with a repeated measures one-way ANOVA, followed by Tukey’s test for multiple comparison (E) . Asterisks indicate statistical significance as follows: p < 0.05*, p < 0.01**, p < 0.0001****.

Article Snippet: A day later inserts were transferred into a cellZscope -device ( cellZscope + ® , nanoAnalytics, Münster, Germany) and cultured until they were confluent.

Techniques: Standard Deviation, Incubation, Comparison, Permeability, Concentration Assay