Review



oligo gearray human neurogenesis and neural stem cell microarray  (SuperArray Bioscience Corporation)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    SuperArray Bioscience Corporation oligo gearray human neurogenesis and neural stem cell microarray
    Oligo Gearray Human Neurogenesis And Neural Stem Cell Microarray, supplied by SuperArray Bioscience Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/oligo+gearray+human+neurogenesis+and+neural+stem+cell+microarrays/pm22150777-84-5-10
    Average 90 stars, based on 1 article reviews
    oligo gearray human neurogenesis and neural stem cell microarray - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    Microarray:

    Article Title: Ethanol affects differentiation-related pathways and suppresses Wnt signaling protein expression in human neural stem cells.
    Article Snippet: Fold change (1-fold = 100%) in the expression of genes from EtOHtreated and control samples were compared using integrated GEArray expression analysis software. .. Oligo GEArray Human Neurogenesis and Neural Stem Cell Microarray from SuperArray Biosciences contained 263 genes which included positive and negative regulators of cell proliferation, negative regulators of cell cycle, cell cycle arrest genes, regulators of cell differentiation, synaptic transmission, synaptogenesis, apoptosis, and cell adhesion. ..

    Cell Differentiation:

    Article Title: Ethanol affects differentiation-related pathways and suppresses Wnt signaling protein expression in human neural stem cells.
    Article Snippet: Fold change (1-fold = 100%) in the expression of genes from EtOHtreated and control samples were compared using integrated GEArray expression analysis software. .. Oligo GEArray Human Neurogenesis and Neural Stem Cell Microarray from SuperArray Biosciences contained 263 genes which included positive and negative regulators of cell proliferation, negative regulators of cell cycle, cell cycle arrest genes, regulators of cell differentiation, synaptic transmission, synaptogenesis, apoptosis, and cell adhesion. ..

    Transmission Assay:

    Article Title: Ethanol affects differentiation-related pathways and suppresses Wnt signaling protein expression in human neural stem cells.
    Article Snippet: Fold change (1-fold = 100%) in the expression of genes from EtOHtreated and control samples were compared using integrated GEArray expression analysis software. .. Oligo GEArray Human Neurogenesis and Neural Stem Cell Microarray from SuperArray Biosciences contained 263 genes which included positive and negative regulators of cell proliferation, negative regulators of cell cycle, cell cycle arrest genes, regulators of cell differentiation, synaptic transmission, synaptogenesis, apoptosis, and cell adhesion. ..



    Similar Products

    86
    Charles River Laboratories retrogenix cell microarray
    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
    Retrogenix Cell Microarray, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/pmc13276592-382-1-1
    Average 86 stars, based on 1 article reviews
    retrogenix cell microarray - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Charles River Laboratories retrogenix cell microarray 30
    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
    Retrogenix Cell Microarray 30, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/10__1016_slash_j__isci__2026__116022-268-1-1
    Average 86 stars, based on 1 article reviews
    retrogenix cell microarray 30 - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Charles River Laboratories retrogenix cell microarray technology
    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
    Retrogenix Cell Microarray Technology, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/pmc12977278-382-14-18
    Average 86 stars, based on 1 article reviews
    retrogenix cell microarray technology - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Charles River Laboratories cell microarray technology screen
    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
    Cell Microarray Technology Screen, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/pm41742895-65-13-17
    Average 86 stars, based on 1 article reviews
    cell microarray technology screen - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Charles River Laboratories anti ccr8 antibodies retrogenix cell microarray technology
    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
    Anti Ccr8 Antibodies Retrogenix Cell Microarray Technology, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/10__1158_slash_1535___7163__mct___25___0367-84-5-7
    Average 86 stars, based on 1 article reviews
    anti ccr8 antibodies retrogenix cell microarray technology - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Charles River Laboratories retrogenix s cell microarray technology
    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell <t>Microarray</t> Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.
    Retrogenix S Cell Microarray Technology, supplied by Charles River Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cell+microarray+assay/cell+microarray+screen+technology/us12435107-399-3-3
    Average 86 stars, based on 1 article reviews
    retrogenix s cell microarray technology - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    Image Search Results


    BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell Microarray Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.

    Journal: iScience

    Article Title: Preclinical assessment of broadly neutralizing HIV-1 antibody BNT351 with optimized pharmacokinetics and potent antiviral activity

    doi: 10.1016/j.isci.2026.116022

    Figure Lengend Snippet: BNT351 shows comparable target affinity to 1-18 and no off-target binding (A) Left: the binding affinity of BNT351 and 1-18 to the stabilized HIV-1 envelope protein trimer (SOSIP BG505.664 ) by SPR (mean and individual values of triplicate measurements). Also see A. Right: binding of BNT351 and 1-18 to SOSIP BG505.664 by ELISA (mean ± standard deviation of triplicate measurements). (B) BNT351’s off-target binding was assessed by Retrogenix Cell Microarray Technology platform. Interactions identified during the library screen with ∼6,500 human proteins are shown. Also, see . Interaction with pepsinogen C (PGC) that appeared to be specific was re-tested by flow cytometry with HEK293 cells transfected with PGC. HEK293 cells transfected with FcγRIIIa and FcεRIg were used as a positive control. Duplicate measurements are shown for flow cytometry.

    Article Snippet: The Retrogenix cell microarray was performed by Charles River Laboratories and included 6,105 full-length human proteins (plasma membrane proteins, secreted or a cell surface-tethered secreted proteins) and 400 human heterodimers.

    Techniques: Binding Assay, Enzyme-linked Immunosorbent Assay, Standard Deviation, Microarray, Flow Cytometry, Transfection, Positive Control