bloch simulator (MathWorks Inc)
Structured Review
Bloch Simulator, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/bloch+simulation/pm39166302-51-32-39
Average 90 stars, based on 1 article reviews
Images
Related Articles
other:Article Title: Toward structure and metabolism of glycogen C 1 -C 6 in humans at 7 T by localized 13 C MRS using low-power bilevel broadband 1 H decoupling. Article Snippet: To evaluate the hyperbolic Article Title: Improved off-resonance phase behavior using a phase-inverted adiabatic half-passage pulse for 13 C MRS in humans at 7 T. Article Snippet: To evaluate and compare the Article Title: Comparative analysis of SINC-shaped and SLR pulses performance for contiguous multi-slice fast spin-echo imaging using metamaterial-based MRI. Article Snippet: Objective To comparatively assess the performance of highly selective pulses computed with the SLR algorithm in fast-spin echo (FSE) within the current radiofrequency safety limits using a metamaterial-based coil for wrist magnetic resonance imaging.. Methods Apodized SINC pulses commonly used for clinical FSE sequences were considered as a reference.. Selective SLR pulses with a time-bandwidth product of four were constructed in the MATPULSE program. Article Title: Effect of labelling plane angulation and position on labelling efficiency and cerebral blood flow quantification in pseudo-continuous arterial spin labelling. Article Snippet: To estimate the theoretical Article Title: Using spectrally-selective radiofrequency pulses to enhance lactate signal for diffusion-weighted MRS measurements in vivo. Article Snippet: Article Title: Systems and methods for designing multidimensional selective adiabatic pulses Article Snippet: An Fat:Article Title: Water-Only Look-Locker Inversion recovery (WOLLI) T 1 mapping Article Snippet: .. Simulations were performed in Sequencing:Article Title: B 1 inhomogeneity-corrected T 1 mapping and quantitative magnetization transfer imaging via simultaneously estimating Bloch-Siegert shift and magnetization transfer effects. Article Snippet: Funding information National Institute of Arthritis and Musculoskeletal and Skin Diseases, Grant/Award Numbers: R01AR079442, R01AR081344; National Institute of Biomedical Imaging and Bioengineering, Grant/Award Numbers: K01EB030045, P41EB022544, R01EB033582, R21EB031185, T32EB013180 Purpose: To introduce a method of inducing Bloch-Siegert shift and magnetization Transfer Simultaneously (BTS) and demonstrate its utilization for measuring binary spin-bath model parameters free pool spin–lattice relaxation (TF 1 ), macromolecular fraction (f ), magnetization exchange rate (kF) and local transmit field (B1 ).. Theory and Methods: Bloch-Siegert shift and magnetization transfer is simultaneously induced through the application of off-resonance irradiation in between excitation and acquisition of an RF-spoiled gradient-echo scheme.. Applying the binary spin-bath model, an analytical signal equation is derived and verified through Bloch simulations. |
