Review



anfis based controller in simulink  (MathWorks Inc)


Bioz Verified Symbol MathWorks Inc is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    MathWorks Inc anfis based controller in simulink
    Anfis Based Controller In Simulink, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 890 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/ppr0641237-41-18-22
    Average 96 stars, based on 890 article reviews
    anfis based controller in simulink - by Bioz Stars, 2026-11
    96/100 stars

    Images

    Related Articles

    Control:

    Article Title: Efficient speed and voltage regulation of BLDC motor drive for EV applications using a multi-device interleaved DC-DC bidirectional converter with TIFDNFD-SFOA controller.
    Article Snippet: .. The design and control implementations were analyzed and simulated using the MATLAB/Simulink environment. ..

    Article Title: Predictive temperature control of electric two wheeler hub motor using gradient aware neural regulation with degradation tracking and fault tolerant multi condition torque adaptation.
    Article Snippet: .. This section presents the full state transition design of the Fallback and Safe-Mode Management System (FSMS), implemented as a Stateflow® chart within the Simulink® control environment and subsequently embedded for real-time execution on the VCU. ..

    Article Title: A novel Fibonacci sequence-based motion profile
    Article Snippet: .. To verify the effectiveness and feasibility of the motion profile design method proposed in this paper, a unified closed-loop velocity control model was established in MATLAB/Simulink. ..

    Article Title: Fault Detection and Monitoring in Induction Machines Using Data-Driven Model Drift Detection
    Article Snippet: The motor is driven by a custom-designed Variable Speed Drive (VSD) developed at the university laboratory, which utilizes a Texas Instruments TMS320F28388D DSP to command a two-level voltage-source inverter. .. Regarding the software implementation, MATLAB R2024a and Simulink 24.1 were used to design, compile, and deploy the discrete-time control algorithms onto the VSD’s embedded processor. ..

    Article Title: Fault Detection and Monitoring in Induction Machines Using Data-Driven Model Drift Detection.
    Article Snippet: The motor is driven by a custom-designed Variable Speed Drive (VSD) developed at the university laboratory, which utilizes a Texas Instruments TMS320F28388D DSP to command a two-level voltage-source inverter. .. Regarding the software implementation, MATLAB R2024a and Simulink 24.1 were used to design, compile, and deploy the discrete-time control algorithms onto the VSD’s embedded processor. ..

    Software:

    Article Title: Fault Detection and Monitoring in Induction Machines Using Data-Driven Model Drift Detection
    Article Snippet: The motor is driven by a custom-designed Variable Speed Drive (VSD) developed at the university laboratory, which utilizes a Texas Instruments TMS320F28388D DSP to command a two-level voltage-source inverter. .. Regarding the software implementation, MATLAB R2024a and Simulink 24.1 were used to design, compile, and deploy the discrete-time control algorithms onto the VSD’s embedded processor. ..

    Article Title: Fault Detection and Monitoring in Induction Machines Using Data-Driven Model Drift Detection.
    Article Snippet: The motor is driven by a custom-designed Variable Speed Drive (VSD) developed at the university laboratory, which utilizes a Texas Instruments TMS320F28388D DSP to command a two-level voltage-source inverter. .. Regarding the software implementation, MATLAB R2024a and Simulink 24.1 were used to design, compile, and deploy the discrete-time control algorithms onto the VSD’s embedded processor. ..



    Similar Products

    96
    MathWorks Inc anfis controller main parts
    Fig. 9. Configuration of <t>ANFIS</t> <t>Controller</t> main parts in Simulink environment.
    Anfis Controller Main Parts, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/pm40075169-348-2-7
    Average 96 stars, based on 1 article reviews
    anfis controller main parts - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    96
    MathWorks Inc anfis designer
    Fig. 9. Configuration of <t>ANFIS</t> <t>Controller</t> main parts in Simulink environment.
    Anfis Designer, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/pmc11297024-159-39-43
    Average 96 stars, based on 1 article reviews
    anfis designer - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    96
    MathWorks Inc anfis based controller in simulink
    Fig. 9. Configuration of <t>ANFIS</t> <t>Controller</t> main parts in Simulink environment.
    Anfis Based Controller In Simulink, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/ppr0641237-41-18-22
    Average 96 stars, based on 1 article reviews
    anfis based controller in simulink - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    90
    microSYST Systemelectronic GmbH optimizing compliant gripper mechanism design by employing an effective bi-algorithm: fuzzy logic and anfis
    Fig. 9. Configuration of <t>ANFIS</t> <t>Controller</t> main parts in Simulink environment.
    Optimizing Compliant Gripper Mechanism Design By Employing An Effective Bi Algorithm: Fuzzy Logic And Anfis, supplied by microSYST Systemelectronic GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/optimizing+compliant+gripper+mechanism+design+by+employing+an+effective+bi+algorithm++fuzzy+logic+and+anfis/10__1109_slash_access__2023__3300590-254-10-26
    Average 90 stars, based on 1 article reviews
    optimizing compliant gripper mechanism design by employing an effective bi-algorithm: fuzzy logic and anfis - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    96
    MathWorks Inc anfis controller mathematical simulink model
    Fig. 9. Configuration of <t>ANFIS</t> <t>Controller</t> main parts in Simulink environment.
    Anfis Controller Mathematical Simulink Model, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/10__3390_slash_wevj12030098-199-1-4
    Average 96 stars, based on 1 article reviews
    anfis controller mathematical simulink model - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    96
    MathWorks Inc anfis controller design
    Fig. 4. Membership functions and value gaps of CF1 and CFac of the input variables of <t>ANFIS.</t> (a) Input membership functions, CF1 and (b) input membership functions, CFac.
    Anfis Controller Design, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/10__1016_slash_j__asej__2017__05__006-151-5-10
    Average 96 stars, based on 1 article reviews
    anfis controller design - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    96
    MathWorks Inc anfis control
    Fig. 4. Membership functions and value gaps of CF1 and CFac of the input variables of <t>ANFIS.</t> (a) Input membership functions, CF1 and (b) input membership functions, CFac.
    Anfis Control, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/anfis+designer/Simulink+Control+Design/10__1049_slash_iet___gtd__2016__1164-119-4-7
    Average 96 stars, based on 1 article reviews
    anfis control - by Bioz Stars, 2026-11
    96/100 stars
      Buy from Supplier

    Image Search Results


    Fig. 9. Configuration of ANFIS Controller main parts in Simulink environment.

    Journal: Scientific reports

    Article Title: Novel technique for precise derating torque of induction motors using ANFIS.

    doi: 10.1038/s41598-025-92821-z

    Figure Lengend Snippet: Fig. 9. Configuration of ANFIS Controller main parts in Simulink environment.

    Article Snippet: Configuration of ANFIS Controller main parts in Simulink environment.

    Techniques:

    Fig. 4. Membership functions and value gaps of CF1 and CFac of the input variables of ANFIS. (a) Input membership functions, CF1 and (b) input membership functions, CFac.

    Journal: Ain Shams Engineering Journal

    Article Title: NERC’s control performance standards based load frequency controller for a multi area deregulated power system with ANFIS approach

    doi: 10.1016/j.asej.2017.05.006

    Figure Lengend Snippet: Fig. 4. Membership functions and value gaps of CF1 and CFac of the input variables of ANFIS. (a) Input membership functions, CF1 and (b) input membership functions, CFac.

    Article Snippet: The basic steps for the ANFIS controller design in MATLAB/ Simulink environment (Fig. 1) are mentioned below [6,27] (1) Model and simulate the test system with simulink and fuzzy logic controller with the given rule base. (2) Collect the training data while simulating the model with fuzzy logic controller. (3) The two inputs, i.e., CF1 and CFac and the output signal provides the training data. (4) Use anfisedit to generate the ANFIS .fis file. (5) Arrange the training data collected in Step 2 and generate the FIS with Gaussian membership function. (6) Trains the collected data with the generated FIS up to a par- ticular no. of Epochs. (7) Save the FIS.

    Techniques:

    Fig. 11. Excess raise/lower signals of GENCO-1 with three different controllers. (a) Speed changer raise/lower signals of GENCO-1 with three different controllers. (b) Excess raise/lower signals of GENCO-1 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-1 of ANFIS controller over NERC standards-based ANFIS controller.

    Journal: Ain Shams Engineering Journal

    Article Title: NERC’s control performance standards based load frequency controller for a multi area deregulated power system with ANFIS approach

    doi: 10.1016/j.asej.2017.05.006

    Figure Lengend Snippet: Fig. 11. Excess raise/lower signals of GENCO-1 with three different controllers. (a) Speed changer raise/lower signals of GENCO-1 with three different controllers. (b) Excess raise/lower signals of GENCO-1 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-1 of ANFIS controller over NERC standards-based ANFIS controller.

    Article Snippet: The basic steps for the ANFIS controller design in MATLAB/ Simulink environment (Fig. 1) are mentioned below [6,27] (1) Model and simulate the test system with simulink and fuzzy logic controller with the given rule base. (2) Collect the training data while simulating the model with fuzzy logic controller. (3) The two inputs, i.e., CF1 and CFac and the output signal provides the training data. (4) Use anfisedit to generate the ANFIS .fis file. (5) Arrange the training data collected in Step 2 and generate the FIS with Gaussian membership function. (6) Trains the collected data with the generated FIS up to a par- ticular no. of Epochs. (7) Save the FIS.

    Techniques:

    Fig. 12. Excess raise/lower signals of Genco-2 with three different controllers. (a) Speed changer raise/lower signals of GENCO-2 with three different controllers. (b) Excess raise/lower signals of GENCO-2 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-2 of ANFIS controller over NERC standards-based ANFIS controller.

    Journal: Ain Shams Engineering Journal

    Article Title: NERC’s control performance standards based load frequency controller for a multi area deregulated power system with ANFIS approach

    doi: 10.1016/j.asej.2017.05.006

    Figure Lengend Snippet: Fig. 12. Excess raise/lower signals of Genco-2 with three different controllers. (a) Speed changer raise/lower signals of GENCO-2 with three different controllers. (b) Excess raise/lower signals of GENCO-2 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-2 of ANFIS controller over NERC standards-based ANFIS controller.

    Article Snippet: The basic steps for the ANFIS controller design in MATLAB/ Simulink environment (Fig. 1) are mentioned below [6,27] (1) Model and simulate the test system with simulink and fuzzy logic controller with the given rule base. (2) Collect the training data while simulating the model with fuzzy logic controller. (3) The two inputs, i.e., CF1 and CFac and the output signal provides the training data. (4) Use anfisedit to generate the ANFIS .fis file. (5) Arrange the training data collected in Step 2 and generate the FIS with Gaussian membership function. (6) Trains the collected data with the generated FIS up to a par- ticular no. of Epochs. (7) Save the FIS.

    Techniques:

    Fig. 13. Excess raise/lower signals of GENCO-3 with three different controllers. (a) Speed changer raise/lower signals of GENCO-3 with three different controllers. (b) Excess raise/lower signals of GENCO-3 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-3 of ANFIS controller over NERC standards-based ANFIS controller.

    Journal: Ain Shams Engineering Journal

    Article Title: NERC’s control performance standards based load frequency controller for a multi area deregulated power system with ANFIS approach

    doi: 10.1016/j.asej.2017.05.006

    Figure Lengend Snippet: Fig. 13. Excess raise/lower signals of GENCO-3 with three different controllers. (a) Speed changer raise/lower signals of GENCO-3 with three different controllers. (b) Excess raise/lower signals of GENCO-3 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-3 of ANFIS controller over NERC standards-based ANFIS controller.

    Article Snippet: The basic steps for the ANFIS controller design in MATLAB/ Simulink environment (Fig. 1) are mentioned below [6,27] (1) Model and simulate the test system with simulink and fuzzy logic controller with the given rule base. (2) Collect the training data while simulating the model with fuzzy logic controller. (3) The two inputs, i.e., CF1 and CFac and the output signal provides the training data. (4) Use anfisedit to generate the ANFIS .fis file. (5) Arrange the training data collected in Step 2 and generate the FIS with Gaussian membership function. (6) Trains the collected data with the generated FIS up to a par- ticular no. of Epochs. (7) Save the FIS.

    Techniques:

    Fig. 14. Excess raise/lower signals of GENCO-4 with three different controllers. (a) Speed changer raise/lower signals of GENCO-4 with three different controllers. (b) Excess raise/lower signals of GENCO-4 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-4 of ANFIS controller over NERC standards-based ANFIS controller.

    Journal: Ain Shams Engineering Journal

    Article Title: NERC’s control performance standards based load frequency controller for a multi area deregulated power system with ANFIS approach

    doi: 10.1016/j.asej.2017.05.006

    Figure Lengend Snippet: Fig. 14. Excess raise/lower signals of GENCO-4 with three different controllers. (a) Speed changer raise/lower signals of GENCO-4 with three different controllers. (b) Excess raise/lower signals of GENCO-4 of PID controller over NERC standards-based ANFIS controller. (c) Excess raise/lower signals of GENCO-4 of ANFIS controller over NERC standards-based ANFIS controller.

    Article Snippet: The basic steps for the ANFIS controller design in MATLAB/ Simulink environment (Fig. 1) are mentioned below [6,27] (1) Model and simulate the test system with simulink and fuzzy logic controller with the given rule base. (2) Collect the training data while simulating the model with fuzzy logic controller. (3) The two inputs, i.e., CF1 and CFac and the output signal provides the training data. (4) Use anfisedit to generate the ANFIS .fis file. (5) Arrange the training data collected in Step 2 and generate the FIS with Gaussian membership function. (6) Trains the collected data with the generated FIS up to a par- ticular no. of Epochs. (7) Save the FIS.

    Techniques: