Review



sony id7000 software  (Sony Biotechnology)


Bioz Verified Symbol Sony Biotechnology is a verified supplier
Bioz Manufacturer Symbol Sony Biotechnology manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Sony Biotechnology sony id7000 software
    Sony Id7000 Software, supplied by Sony Biotechnology, used in various techniques. Bioz Stars score: 99/100, based on 801 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/ID7000+Spectral+Cell+Analyzer/pmc13120821-442-7-7
    Average 99 stars, based on 801 article reviews
    sony id7000 software - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    other:

    Article Title: Co-targeting KRAS and BCL-2 induces pyroptosis and antitumor tertiary lymphoid structures
    Article Snippet: Data were acquired on a flow cytometer (SONY ID7000) and analyzed using FlowJo software.

    Article Title: Setup and Analysis of Human Tonsil and Adenoid‐Based Immune Organoids for Studying T and B Cell‐Mediated Adaptive Immunity
    Article Snippet: Immune organoids in culture (from Basic Protocol ) Cell culture medium (see recipe) 1× PBS (Thermo Fisher Scientific, cat. no. 14190169) Zombie NIR fixable viability kit (BioLegend, cat. no. 423106) Flow cytometry buffer (see recipe) Human TruStain FcX (BioLegend, cat. no. 422302) Normal mouse serum (Invitrogen, cat. no. 10410; alternatively, Merck, cat. no. NS03L) Antibodies for flow cytometry (see Table ) BD Horizon Brilliant Stain Buffer Plus (BD, cat. no. 566385) eBiosciences FoxP3/Transcription Factor Staining Buffer Set (Thermo Fisher Scientific, cat. no. 00‐5523‐00) Compensation beads (BioLegend, cat. no. 424602) Incubator (with 5% CO , 37°C) 96‐well cell culture plate, suspension, U‐bottom (Sarstedt, cat. no. 83.3925.500) 96‐well V‐bottom micro test plate (Sarstedt, cat. no. 82.1583) Centrifuge (Eppendorf, cat. no. 5811000015) 200‐μl multichannel piston pipette (Mettler Toledo, cat. no. 17013810) 200‐μl pipette tips (Mettler Toledo, cat. no. 30389240) 15‐ml centrifuge tube (Greiner Bio‐One, cat. no. 188271) 1‐ml piston pipette (Mettler Toledo, cat. no. 17014382) 1‐ml pipette tips (Mettler Toledo, cat. no. 30389223) Eppendorf tubes (Eppendorf, cat. no. 0030121023) Heat block ThermoMixer C (Eppendorf, cat. no. EP5382000015) Ice bucket and ice 20‐μl piston pipette (Mettler Toledo, cat. no. 17011788) 20‐μl pipette tips (Mettler Toledo, cat. no. 30389225) Sony ID7000 spectral analyzer (Sony Biotechnology) or similar Sony ID7000 analyzer software (Sony Biotechnology) or similar FlowJo v.10 (Waters)

    Flow Cytometry:

    Article Title: A 21□Color Spectral Flow Cytometry Panel for Comprehensive Immunophenotyping of Rat Tissues and a Companion 9□Color T□Cell Functional Assay
    Article Snippet: .. All flow cytometry data was acquired or analyzed using ID7000 software (Sony Biotechnology). ..

    Article Title: Δ133p53α, a senescence-inhibitory p53 isoform, attenuates accelerated aging in progeria mice
    Article Snippet: T lymphocytes were isolated by negative selection using the EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies, #19851). .. Flow cytometry was performed according to standard procedures to detect CD3 expression using an anti-CD3-BUV395 antibody (BD Biosciences, #563565) and EGFP fluorescence in the FITC/EGFP channel, followed by data acquisition using a Sony ID7000 spectral cell analyzer and data analysis using FlowJo software. ..

    Article Title: Compartment-specific PPARδ activity controls the outcome of cancer-immune cell competition and immunotherapy efficacy.
    Article Snippet: Absolute numbers were calculated based on acquired cell events and the ratio of acquired to total CountBright Absolute Counting Beads (Invitrogen, C36950) added to the sample. .. Instrument Flow cytometry data was acquired on a Becton Dickinson LSRII Cell Analyzer or Sony ID7000 spectral cell analyzer. ..

    Article Title: Microbiota-regulated TCDCA associates with Parkinson's disease severity and promotes BBB dysfunction through VSMC TGR5 signaling in mice.
    Article Snippet: .. Stained cells were analyzed using a Sony ID7000 flow cytometer (Sony Biotechnology, Japan). ..

    Software:

    Article Title: A 21□Color Spectral Flow Cytometry Panel for Comprehensive Immunophenotyping of Rat Tissues and a Companion 9□Color T□Cell Functional Assay
    Article Snippet: .. All flow cytometry data was acquired or analyzed using ID7000 software (Sony Biotechnology). ..

    Article Title: Δ133p53α, a senescence-inhibitory p53 isoform, attenuates accelerated aging in progeria mice
    Article Snippet: T lymphocytes were isolated by negative selection using the EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies, #19851). .. Flow cytometry was performed according to standard procedures to detect CD3 expression using an anti-CD3-BUV395 antibody (BD Biosciences, #563565) and EGFP fluorescence in the FITC/EGFP channel, followed by data acquisition using a Sony ID7000 spectral cell analyzer and data analysis using FlowJo software. ..

    Cytometry:

    Article Title: Δ133p53α, a senescence-inhibitory p53 isoform, attenuates accelerated aging in progeria mice
    Article Snippet: T lymphocytes were isolated by negative selection using the EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies, #19851). .. Flow cytometry was performed according to standard procedures to detect CD3 expression using an anti-CD3-BUV395 antibody (BD Biosciences, #563565) and EGFP fluorescence in the FITC/EGFP channel, followed by data acquisition using a Sony ID7000 spectral cell analyzer and data analysis using FlowJo software. ..

    Article Title: Compartment-specific PPARδ activity controls the outcome of cancer-immune cell competition and immunotherapy efficacy.
    Article Snippet: Absolute numbers were calculated based on acquired cell events and the ratio of acquired to total CountBright Absolute Counting Beads (Invitrogen, C36950) added to the sample. .. Instrument Flow cytometry data was acquired on a Becton Dickinson LSRII Cell Analyzer or Sony ID7000 spectral cell analyzer. ..

    Expressing:

    Article Title: Δ133p53α, a senescence-inhibitory p53 isoform, attenuates accelerated aging in progeria mice
    Article Snippet: T lymphocytes were isolated by negative selection using the EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies, #19851). .. Flow cytometry was performed according to standard procedures to detect CD3 expression using an anti-CD3-BUV395 antibody (BD Biosciences, #563565) and EGFP fluorescence in the FITC/EGFP channel, followed by data acquisition using a Sony ID7000 spectral cell analyzer and data analysis using FlowJo software. ..

    Fluorescence:

    Article Title: Δ133p53α, a senescence-inhibitory p53 isoform, attenuates accelerated aging in progeria mice
    Article Snippet: T lymphocytes were isolated by negative selection using the EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies, #19851). .. Flow cytometry was performed according to standard procedures to detect CD3 expression using an anti-CD3-BUV395 antibody (BD Biosciences, #563565) and EGFP fluorescence in the FITC/EGFP channel, followed by data acquisition using a Sony ID7000 spectral cell analyzer and data analysis using FlowJo software. ..

    Analysis:

    Article Title: Δ133p53α, a senescence-inhibitory p53 isoform, attenuates accelerated aging in progeria mice
    Article Snippet: T lymphocytes were isolated by negative selection using the EasySep Mouse T Cell Isolation Kit (STEMCELL Technologies, #19851). .. Flow cytometry was performed according to standard procedures to detect CD3 expression using an anti-CD3-BUV395 antibody (BD Biosciences, #563565) and EGFP fluorescence in the FITC/EGFP channel, followed by data acquisition using a Sony ID7000 spectral cell analyzer and data analysis using FlowJo software. ..

    Staining:

    Article Title: Microbiota-regulated TCDCA associates with Parkinson's disease severity and promotes BBB dysfunction through VSMC TGR5 signaling in mice.
    Article Snippet: .. Stained cells were analyzed using a Sony ID7000 flow cytometer (Sony Biotechnology, Japan). ..



    Similar Products

    99
    Sony Biotechnology id7000 software
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Id7000 Software, supplied by Sony Biotechnology, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/ID7000+Spectral+Cell+Analyzer/bio_rxiv__64898__2026__10__13__758716-91-9-11
    Average 99 stars, based on 1 article reviews
    id7000 software - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Sony Biotechnology sony biotechnology id7000 software
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Sony Biotechnology Id7000 Software, supplied by Sony Biotechnology, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/ID7000+Spectral+Cell+Analyzer/pm42844481-1501-0-0
    Average 99 stars, based on 1 article reviews
    sony biotechnology id7000 software - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    95
    Randox biochemistry analyzer
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Biochemistry Analyzer, supplied by Randox, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/RX+daytona+%2B+(with+ISE)+Analyser%2C+RX+daytona+%2B+(without+ISE)+Analyser%2C+RX+daytona+%2B+PC+and+software%2C+Printer/pmc13694730-249-14-18
    Average 95 stars, based on 1 article reviews
    biochemistry analyzer - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    99
    Bruker Corporation fields 17 3 microct ct analyzer software
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Fields 17 3 Microct Ct Analyzer Software, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/Micro-CT/pm42816584-731-27-32
    Average 99 stars, based on 1 article reviews
    fields 17 3 microct ct analyzer software - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    Cellular Technology Ltd s6 universal analyzer
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    S6 Universal Analyzer, supplied by Cellular Technology Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/ImmunoSpot+Software/10__1038_slash_s41541___026___01580___z-299-15-13
    Average 99 stars, based on 1 article reviews
    s6 universal analyzer - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    99
    TESCAN USA Inc integrated mineral analyzer tima software 2 9 0
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Integrated Mineral Analyzer Tima Software 2 9 0, supplied by TESCAN USA Inc, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/TIMA/10__1016_slash_j__powtec__2026__123127-116-29-28
    Average 99 stars, based on 1 article reviews
    integrated mineral analyzer tima software 2 9 0 - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    95
    Randox rx daytona automated chemistry analyzer
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Rx Daytona Automated Chemistry Analyzer, supplied by Randox, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/RX+daytona+%2B+(with+ISE)+Analyser%2C+RX+daytona+%2B+(without+ISE)+Analyser%2C+RX+daytona+%2B+PC+and+software%2C+Printer/10__1186_slash_s12917___026___05789___x-64-5-10
    Average 95 stars, based on 1 article reviews
    rx daytona automated chemistry analyzer - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    99
    Cellular Technology Ltd immunospot analyzer ctl
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Immunospot Analyzer Ctl, supplied by Cellular Technology Ltd, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/ImmunoSpot+Software/pm41699066-82-6-6
    Average 99 stars, based on 1 article reviews
    immunospot analyzer ctl - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    86
    Brainvision Inc bv analyzer software
    Configuration of <t>ID7000</t> The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.
    Bv Analyzer Software, supplied by Brainvision Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/analyzer+software/analyzer+brainvision+software/pm42270747-95-8-11
    Average 86 stars, based on 1 article reviews
    bv analyzer software - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    Image Search Results


    Configuration of ID7000 The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.

    Journal: bioRxiv

    Article Title: A 21□Color Spectral Flow Cytometry Panel for Comprehensive Immunophenotyping of Rat Tissues and a Companion 9□Color T□Cell Functional Assay

    doi: 10.64898/2026.10.13.758716

    Figure Lengend Snippet: Configuration of ID7000 The SONY ID7000 is equipped with five lasers (355□ nm, 405 □nm, 488 □nm, 561 □nm, and 637□ nm) and 149 detectors, enabling detection of the full fluorochrome emission spectrum.

    Article Snippet: All flow cytometry data was acquired or analyzed using ID7000 software (Sony Biotechnology).

    Techniques:

    Journal: bioRxiv

    Article Title: A 21□Color Spectral Flow Cytometry Panel for Comprehensive Immunophenotyping of Rat Tissues and a Companion 9□Color T□Cell Functional Assay

    doi: 10.64898/2026.10.13.758716

    Figure Lengend Snippet: Instrument configuration for the SONY 5 laser ID7000. Sony ID7000 flow cytometer laser detection channels and fluorescent antibodies. The antibodies and fluorophores used in this panel are indicated on the corresponding detectors.

    Article Snippet: All flow cytometry data was acquired or analyzed using ID7000 software (Sony Biotechnology).

    Techniques: Flow Cytometry

    Unmixing and Adjustments: N×N plots viewed with the ID7000™ Unmixing Viewer. Unmixing was performed on the live cell population. Unmixed data with B220-BUV496 depicted as an example on the x-axis and all other fluorochromes plotted on the y-axis. Examples of unmixing errors and corrected unmixing results are indicated by red boxes

    Journal: bioRxiv

    Article Title: A 21□Color Spectral Flow Cytometry Panel for Comprehensive Immunophenotyping of Rat Tissues and a Companion 9□Color T□Cell Functional Assay

    doi: 10.64898/2026.10.13.758716

    Figure Lengend Snippet: Unmixing and Adjustments: N×N plots viewed with the ID7000™ Unmixing Viewer. Unmixing was performed on the live cell population. Unmixed data with B220-BUV496 depicted as an example on the x-axis and all other fluorochromes plotted on the y-axis. Examples of unmixing errors and corrected unmixing results are indicated by red boxes

    Article Snippet: All flow cytometry data was acquired or analyzed using ID7000 software (Sony Biotechnology).

    Techniques: