    Vision RT Ltd optical surface imaging (osi) systems alignrt
    Optical Surface Imaging (Osi) Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/optical+surface+monitoring+system+alignrt/pmc12149718-42-9-10
    Average 90 stars, based on 1 article reviews
    optical surface imaging (osi) systems alignrt - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Characteristics of breathing-adapted gating using surface guidance for use in particle therapy: A phantom-based end-to-end test from CT simulation to dose delivery.
    Article Snippet: These strategies include (i) expanding the internal margin of the target volume using the internal target volume (ITV) concept,21,22 (ii) utilizing abdominal compression to restrict the tumor motion (e.g., in liver treatments),23 (iii) employing breath-hold methods,23,24 (iv) implementing tumor tracking,24,25 and (v) using breathing-adapted gating approaches to attempt tracking the patient breathing, and irradiating the tumor target during specific breathing phases.26–32 For the latter, four-dimensional computed tomography (4DCT) is used to reconstruct images at specific breathing phases based on either amplitude or phase.28,33–36 Different respiratory monitoring systems (RMSs) are used for both 4DCT imaging and gating, including pressure sensors, skin-surface camera systems, radiofrequencybased systems and fiducial markers in combination with image-guided RT.23,37–41 At Heidelberg Ion Beam Therapy Center (HIT), three optical surface-guided RT (SGRT)38 systems, the AlignRT, SimRT, and GateRT (VisionRT Ltd, London, United Kingdom) have been installed between 2019 and 2021: (i) AlignRT and GateRT at the ion beam gantry treatment room, and (ii) SimRT at a CT scanner in the radiation oncology department.

    Article Title: Optical surface information‐based respiratory phase‐sorting and motion‐incorporated reconstruction for SPECT imaging
    Article Snippet: Newly developed optical surface imaging (OSI) systems, such as AlignRT (VisionRT, London, Great Britain) and Catalyst (C‐Rad, Uppsala, Sweden), have been introduced in external beam radiation therapy.

    Article Title: Optical surface information-based respiratory phase-sorting and motion-incorporated reconstruction for SPECT imaging.
    Article Snippet: Newly developed optical surface imaging (OSI) systems, such as AlignRT (VisionRT, London, Great Britain) and Catalyst (C-Rad, Uppsala, Sweden), have been introduced in external beam radiation therapy.17 These systems enable continuous and touchless scanning of patients’ external surfaces, and several studies have shown clear correlations between external surfaces and internal structures.18,19 Moreover, implementing this method does not require purchasing expensive equipment, a depth camera alone is sufficient.

    Article Title: Exploring stereotactic radiosurgery for tremor using the Varian cone planning system.
    Article Snippet: A phantom-based system was used to determine the optimal treatment delivery parameters for SRS tremor treatment, with imaging by Optical Surface Monitoring System (OSMS), (VisionRT, London, UK, www.visionrt.com) and CBCT/kV/portal images.

    Article Title: Margin derivation from intrafraction patient motion of multi‐target, single isocentre, brain stereotactic radiosurgery treatments
    Article Snippet: All brain SRS treatments were monitored in real‐time with AlignRT, an optical surface monitoring system (OSMS) from Vision RT (Vision RT Ltd. Dove House Arcadia Avenue, London N3 2JU, UK), which offers sub‐millimeter monitoring accuracy.

    Computed Tomography:

    Article Title: Impact of deep inspiration breath hold, surface-guided radiotherapy, and daily CBCT on the organs at risk in breast cancer radiotherapy
    Article Snippet: .. Studies have shown that patient setup accuracy using daily online verification with kilovolt cone-beam computed tomography (kV-CBCT) scans is significantly better compared to SGRT using optical surface monitoring systems (e.g., AlignRT, VisionRT Ltd, London, UK; C-RAD, Uppsala, Sweden), and SGRT is significantly better than the conventional technique of matching three orthogonal in-room laser beams with patient skin marks , . ..



    Similar Products

    90
    Vision RT Ltd optical surface imaging (osi) systems alignrt
    Optical Surface Imaging (Osi) Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/optical+surface+monitoring+system+alignrt/pmc12149718-42-9-10
    Average 90 stars, based on 1 article reviews
    optical surface imaging (osi) systems alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd optical surface imaging systems alignrt
    Optical Surface Imaging Systems Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/optical+surface+monitoring+system+alignrt/pm40123313-23-3-10
    Average 90 stars, based on 1 article reviews
    optical surface imaging systems alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Respiratory Motion catalyst, alignrt, identify surface imaging system
    Catalyst, Alignrt, Identify Surface Imaging System, supplied by Respiratory Motion, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/catalyst++alignrt++identify+surface+imaging+system/pmc11969100-60-1-11
    Average 90 stars, based on 1 article reviews
    catalyst, alignrt, identify surface imaging system - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd surface-guided imaging alignrt version 6.3.2
    Surface Guided Imaging Alignrt Version 6.3.2, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/controlled+surface+monitoring+technique+alignrt/pm39098107-50-20-23
    Average 90 stars, based on 1 article reviews
    surface-guided imaging alignrt version 6.3.2 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd optical surface-guided imaging visionrt–alignrt
    Optical Surface Guided Imaging Visionrt–Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/3+camera+align+rt+system/pmc11204472-63-12-13
    Average 90 stars, based on 1 article reviews
    optical surface-guided imaging visionrt–alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd surface scanning imaging alignrt
    Surface Scanning Imaging Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/controlled+surface+monitoring+technique+alignrt/pm38492672-77-5-9
    Average 90 stars, based on 1 article reviews
    surface scanning imaging alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd surface imaging system alignrt
    Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/alignrt+surface+imaging+system/pmc10646616-142-10-14
    Average 90 stars, based on 1 article reviews
    surface imaging system alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd on-board cbct imaging and surface guidance from alignrt
    Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the <t>AlignRT</t> system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only
    On Board Cbct Imaging And Surface Guidance From Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/linear+accelerator+equipped+with+a+real+time+3d+surface+imaging+system+alignrt/pmc08425866-49-12-13
    Average 90 stars, based on 1 article reviews
    on-board cbct imaging and surface guidance from alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd alignrt surface imaging system
    Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the <t>AlignRT</t> system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only
    Alignrt Surface Imaging System, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/alignrt+surface+imaging+system/pmc08279697-23-9-5
    Average 90 stars, based on 1 article reviews
    alignrt surface imaging system - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vision RT Ltd optical 3d surface imaging system alignrt
    Statistical summary of the <t> AlignRT </t> mean and max magnitude readouts of a phantom.
    Optical 3d Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/alignrt+surface+imaging+system/3d+surface+imaging+system+alignrt/pmc07484878-53-11-12
    Average 90 stars, based on 1 article reviews
    optical 3d surface imaging system alignrt - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the AlignRT system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only

    Journal: Journal of Applied Clinical Medical Physics

    Article Title: Comparison of the dosimetric accuracy of proton breast treatment plans delivered with SGRT and CBCT setups

    doi: 10.1002/acm2.13357

    Figure Lengend Snippet: Surface‐guided radiation therapy (SGRT) setup registration. Left: The surface used for treatment setup by the AlignRT system. Middle: Recreation of the surface surveyed by the AlignRT system using a manually generated chest surface contour (shown in white) on the quality assurance CT (QA‐CT). Right: Fusion image from the planning CT and the QA‐CT after performing an automatic image registration focusing on the chest surface contour only

    Article Snippet: The patient was setup with on‐board CBCT imaging and surface guidance from AlignRT (VisionRT Ltd.) for the first three fractions.

    Techniques: Generated

    Statistical summary of the  AlignRT  mean and max magnitude readouts of a phantom.

    Journal: Journal of Applied Clinical Medical Physics

    Article Title: Validating robotic couch isocentricity with 3D surface imaging

    doi: 10.1002/acm2.12939

    Figure Lengend Snippet: Statistical summary of the AlignRT mean and max magnitude readouts of a phantom.

    Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

    Techniques:

    Statistical summary of the  AlignRT  mean and max magnitude readouts of volunteers.

    Journal: Journal of Applied Clinical Medical Physics

    Article Title: Validating robotic couch isocentricity with 3D surface imaging

    doi: 10.1002/acm2.12939

    Figure Lengend Snippet: Statistical summary of the AlignRT mean and max magnitude readouts of volunteers.

    Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

    Techniques:

    A distribution of the reported deviation magnitude for AlignRT following 0, 0.2, 0.4, 0.6, and 0.8 cm shifts from isocenter, in conjunction with a 90° rotation. Upper and lower panels represent the results from immobilized and nonimmobilized volunteers respectively.

    Journal: Journal of Applied Clinical Medical Physics

    Article Title: Validating robotic couch isocentricity with 3D surface imaging

    doi: 10.1002/acm2.12939

    Figure Lengend Snippet: A distribution of the reported deviation magnitude for AlignRT following 0, 0.2, 0.4, 0.6, and 0.8 cm shifts from isocenter, in conjunction with a 90° rotation. Upper and lower panels represent the results from immobilized and nonimmobilized volunteers respectively.

    Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

    Techniques:

    Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥2 mm using a 2 mm action level on the  AlignRT  displacement vector.

    Journal: Journal of Applied Clinical Medical Physics

    Article Title: Validating robotic couch isocentricity with 3D surface imaging

    doi: 10.1002/acm2.12939

    Figure Lengend Snippet: Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥2 mm using a 2 mm action level on the AlignRT displacement vector.

    Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

    Techniques: Plasmid Preparation

    Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥4 mm using a 4 mm action level on the  AlignRT  displacement vector.

    Journal: Journal of Applied Clinical Medical Physics

    Article Title: Validating robotic couch isocentricity with 3D surface imaging

    doi: 10.1002/acm2.12939

    Figure Lengend Snippet: Represents the number of true/false positives and true/false negatives for detecting couch runouts ≥4 mm using a 4 mm action level on the AlignRT displacement vector.

    Article Snippet: The accuracy of a commercially available optical 3D surface imaging system, AlignRT (VisionRT Ltd., London UK) has been shown by several studies to be within 1 mm., Here we investigate sensitivity and specificity of a surface imaging system for identifying excessive mechanical runout in a robotic couch rotation.

    Techniques: Plasmid Preparation