Review




Structured Review

alcon inc intraocular lens acrysof® iq aspheric iol
Intraocular Lens Acrysof® Iq Aspheric Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+aspheric+iol/pm40565876-62-11-16
Average 90 stars, based on 1 article reviews
intraocular lens acrysof® iq aspheric iol - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system
Article Snippet: – The UltraSert ® preloaded delivery system (preloaded system U; Alcon Laboratories, Inc., Fort Worth, TX, USA) is US Food and Drug Administration (FDA)-approved for use with the AcrySof ® IQ Aspheric IOL (IOL IQ; Alcon Laboratories, Inc.) in patients undergoing cataract surgery and is a single-use system made up of a nozzle, main body, and plunger that delivers the preloaded IOL by manually advancing the plunger with a push mechanism ( ).

Article Title: Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision.
Article Snippet: Methods: Patients hadbilateral cataract surgerywith implantationof a trifocal IOL (Panoptix), anextended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF).. Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires.

Article Title: Toric intraocular lens versus limbal relaxing incisions for corneal astigmatism after phacoemulsification
Article Snippet: Interventions , Intervention characteristics Toric IOLs Type of IOL : AcrySof IQ Toric IOL (Alcon Inc.) LRI Type of IOL : monofocal AcrySof IQ Aspheric IOL (Alcon Inc.) Incision technique : size and location of LRI according to the Nichamin nomogram. Based on the procedure described by Langerman, a vertical limbal relaxing wound was created with a guarded micrometre diamond blade by making a groove concentric to the limbus. Incision depth set at 600 μm equal to approximately 85% of the peripheral corneal thickness at the axis to be cut and the incisions were approximately 3 mm. After the paired incision was made, the penetrating CCI was made along the steepest axis in the upper area for the cataract surgery, along the same axis as the LRI. , .

Article Title: First Clinical Evidence Linking Smoking to Increased Postoperative Macular and Retinal Nerve Fiber Layer Thickness in Cataract Surgery Patients: A Prospective Cohort Study.
Article Snippet: After completing the stop-and-chop technique and removing the cataract, an intraocular lens (AcrySof® IQ aspheric IOL, Alcon Laboratories Inc., Fort Worth, TX, USA) was implanted into the capsular bag.

Article Title: Comparison of corneal endothelial cell loss in FLACS: impact on endothelial cells in different regions
Article Snippet: After removing the cataract, the IOL was implanted, including aspheric IOLs, toric IOLs, and trifocal IOLs from Alcon Laboratories, Inc. and Johnson & Johnson Vision.

Article Title: Efficacy comparison between toric intraocular lens and aspheric intraocular lens plus steep-axis incision in cataract patients with low corneal astigmatism.
Article Snippet: Patients in the test group were implanted with a toric IOL (AcrySof® IQ Toric IOL, Alcon Inc.) and the control group with a single-focus aspheric IOL (AcrySof® IQ Aspheric IOL, Alcon Inc.).

Article Title: First Clinical Evidence Linking Smoking to Increased Postoperative Macular and Retinal Nerve Fiber Layer Thickness in Cataract Surgery Patients: A Prospective Cohort Study
Article Snippet: After completing the stop-and-chop technique and removing the cataract, an intraocular lens (AcrySof ® IQ aspheric IOL, Alcon Laboratories Inc., Fort Worth, TX, USA) was implanted into the capsular bag.

Extraction:

Article Title: Visual outcomes after toric intraocular lens implantation in pediatric eyes undergoing cataract surgery.
Article Snippet: Methods: Children with regular corneal astigmatism of at least 1.5 diopters (D) were included.. A standardized surgical technique with in-the-bag implantation of a toric IOL was performed.. All children were followed up on postoperative day 1 and periodically thereafter, until 36 months postoperatively.



Similar Products

86
Vivity Labs Inc acrysof iq vivity iol
Acrysof Iq Vivity Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity/pmc13123711-198-3-5
Average 86 stars, based on 1 article reviews
acrysof iq vivity iol - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Vivity Labs Inc toric iols acrysof
Toric Iols Acrysof, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity+iol/pm40661044-29-14-15
Average 90 stars, based on 1 article reviews
toric iols acrysof - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Vivity Labs Inc intraocular lens (iol) acrysof iq
Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of <t>IOL</t> with monovision, as per surgery type. IOL = <t>intraocular</t> lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.
Intraocular Lens (Iol) Acrysof Iq, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity+iol/pmc12187150-38-12-19
Average 90 stars, based on 1 article reviews
intraocular lens (iol) acrysof iq - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Vivity Labs Inc acrysof iq vivity edof iol
Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for <t>AcrySof</t> IQ Vivity) intraocular lens <t>(IOL)</t> at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).
Acrysof Iq Vivity Edof Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity+iol/pmc12203608-37-18-20
Average 90 stars, based on 1 article reviews
acrysof iq vivity edof iol - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
alcon inc intraocular lens acrysof® iq aspheric iol
Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for <t>AcrySof</t> IQ Vivity) intraocular lens <t>(IOL)</t> at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).
Intraocular Lens Acrysof® Iq Aspheric Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+aspheric+iol/pm40565876-62-11-16
Average 90 stars, based on 1 article reviews
intraocular lens acrysof® iq aspheric iol - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with monovision, as per surgery type. IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with monovision, as per surgery type. IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques: Standard Deviation

Visual disturbances a at 3 to 6 months after bilateral implantation of IOL with monovision as per surgery type. IOL = intraocular lens; RLE = refractive lens exchange. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Visual disturbances a at 3 to 6 months after bilateral implantation of IOL with monovision as per surgery type. IOL = intraocular lens; RLE = refractive lens exchange. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques:

Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens; SD, standard deviation; VA = visual acuity. a Low monovision: myopic eye >−0.75 D and ≤−0.50 D; medium monovision: myopic eye >−1.00 D and ≤−0.75 D; high monovision: myopic eye ≤−1.00 D.

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens; SD, standard deviation; VA = visual acuity. a Low monovision: myopic eye >−0.75 D and ≤−0.50 D; medium monovision: myopic eye >−1.00 D and ≤−0.75 D; high monovision: myopic eye ≤−1.00 D.

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques: Standard Deviation

Visual disturbances at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Visual disturbances at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques:

Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for AcrySof IQ Vivity) intraocular lens (IOL) at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).

Journal: Frontiers in Medicine

Article Title: Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration

doi: 10.3389/fmed.2025.1505401

Figure Lengend Snippet: Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for AcrySof IQ Vivity) intraocular lens (IOL) at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).

Article Snippet: The aim of this clinical prospective study was to provide more clinical evidence on the use of the AcrySof IQ Vivity EDOF IOL in a series of eyes diagnosed with AMD and implanted with this model, through measuring visual acuity at different distances and assessing visual function using two patient-reported outcome questionnaires.

Techniques: Standard Deviation