Review




Structured Review

Arthrex Inc absorbable interference screw
Absorbable Interference Screw, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/bioabsorbable+screws/pm41722021-51-33-37
Average 86 stars, based on 1 article reviews
absorbable interference screw - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

other:

Article Title: Anterior cruciate ligament reconstruction combined with anterolateral ligament reconstruction using hamstring autograft versus anterior cruciate ligament reconstruction using bone–patellar tendon–bone autograft: a randomised controlled trial with 5-year follow-up
Article Snippet: The ACL portion of the graft (3-part semitendinosus tendon and 1-part gracilis tendon) was fixed on both sides using bioabsorbable screws (BioComposite interference screw: Arthrex) with the knee flexed to 30°.

Article Title: Radiologic maturation and tunnel changes after all-inside versus standard hamstring ACL reconstruction: a prospective comparative study.
Article Snippet: The graft was then shuttled from the tibial tunnel through the femoral socket and fixed on the femoral side using an adjustable-loop suspensory device (Tight-rope RT; Arthrex) and on the tibia using an absorbable interference screw (BioComposite; Arthrex), with a diameter 1 mm greater than the graft and tunnel diameter [27].

Article Title: Autograft Posterior Cruciate Ligament Reconstruction Shows Delayed Maturation and Correlates With Residual Laxity After Multiligament Knee Reconstruction.
Article Snippet: Purpose: To compare anterior cruciate ligament (ACL) graft maturation with other grafts in multiligament knee reconstruction at 1 year postoperatively while also evaluating its relationship with clinical laxity, identifying factors influencing graft maturation, and analyzing tunnel widening.. Methods: This retrospective study included patients between October 2019 and April 2023, who underwent multiligament knee reconstruction using autografts and a 1-year clinical and magnetic resonance imaging follow-up.. The injury was classified according to Schenck’s classification.


Article Title: LARS‐augmented hamstring ACL reconstruction shows better early but similar long‐term outcomes compared with hamstring autograft alone: A systematic review and meta‐analysis
Article Snippet: Zhang et al. [ ] , Retrospective (Level III) , 32/36 , HT/LARS , 2‐strand LARS‐augmented ST , Single‐bundle , Tight cord (Arthrex) , Bioabsorbable screw (Arthrex).



Similar Products

86
Arthrex Inc bio absorbable interference screw
Bio Absorbable Interference Screw, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/bioabsorbable+screws/pmc13254419-99-6-22
Average 86 stars, based on 1 article reviews
bio absorbable interference screw - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Arthrex Inc absorbable interference screw
Absorbable Interference Screw, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/bioabsorbable+screws/pm41722021-51-33-37
Average 86 stars, based on 1 article reviews
absorbable interference screw - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
DePuy Mitek absorbable interference screw biocryl interference screw
Absorbable Interference Screw Biocryl Interference Screw, supplied by DePuy Mitek, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/bioabsorbable+interference+screw/pm40349065-69-17-23
Average 90 stars, based on 1 article reviews
absorbable interference screw biocryl interference screw - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DePuy Synthes absorbable interference screw
Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm <t>absorbable</t> interference screw.
Absorbable Interference Screw, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/milagro+screws/pmc11970040-64-23-33
Average 90 stars, based on 1 article reviews
absorbable interference screw - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Smith & Nephew absorbable interference screw
Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm <t>absorbable</t> interference screw.
Absorbable Interference Screw, supplied by Smith & Nephew, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/bioabsorbable+interference+screw/pmc11780662-73-19-22
Average 90 stars, based on 1 article reviews
absorbable interference screw - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Zimmer Biomet absorbable biocomposite interference screw compositcp tm
Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm <t>absorbable</t> interference screw.
Absorbable Biocomposite Interference Screw Compositcp Tm, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/absorbable+biocomposite+interference+screw+compositcp+tm/pmc11735515-109-37-45
Average 90 stars, based on 1 article reviews
absorbable biocomposite interference screw compositcp tm - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Zimmer Biomet absorbable biocomposite interference screw
Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm <t>absorbable</t> interference screw.
Absorbable Biocomposite Interference Screw, supplied by Zimmer Biomet, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/absorbable+biocomposite+interference+screw/pm39812812-76-37-44
Average 90 stars, based on 1 article reviews
absorbable biocomposite interference screw - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DePuy Synthes milagro® advance interference absorbable screws
Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm <t>absorbable</t> interference screw.
Milagro® Advance Interference Absorbable Screws, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/absorbable+interference+screw/milagro+screws/pm38673520-98-10-15
Average 90 stars, based on 1 article reviews
milagro® advance interference absorbable screws - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm absorbable interference screw.

Journal: Orthopaedic Journal of Sports Medicine

Article Title: Postoperative Knee Extensor Strength After Medial Patellofemoral Ligament Reconstruction Using Superficial Slip of the Quadriceps Tendon and the Factors That Affect Strength Recovery

doi: 10.1177/23259671251325748

Figure Lengend Snippet: Schema of surgical methods. Diagrammatic representation of graft harvest, graft rotation, patellar fixation, and femur fixation. (A) The superior border of the MPFL is approximately 6 mm below the superior pole of the patella, and the inferior border is roughly near the midpoint of the patella. The plane and dissection points for graft harvest. (B) The graft is rotated and turned medially to mimic the anatomic position of the native MPFL. Stay sutures at the patella provide anatomic patellar fixation. (C) Creation of a bone tunnel at the Schöttle point and fixing the graft with a 7-mm absorbable interference screw.

Article Snippet: The graft was pulled into the bone tunnel with the patella centered at the trochlea, and then the graft was fixed using an absorbable interference screw (7 × 23-mm MILAGRO Advance Interference Screw; DePuy Synthes America) under appropriate tension (10-20 N) at 30° of knee flexion ( ).

Techniques: Dissection