chromatography data software (TechLab Inc)
90
Structured Review
TechLab Inc
chromatography data software
Chromatography Data Software, supplied by TechLab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/Chromatography+Software/chromatography+data+software+program/pm12062369-70-19-34
Average 90 stars, based on 1 article reviews
Chromatography Data Software, supplied by TechLab Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/Chromatography+Software/chromatography+data+software+program/pm12062369-70-19-34
Average 90 stars, based on 1 article reviews
chromatography data software - by Bioz Stars,
2026-09
90/100 stars
Images
Related Articles
Chromatography:Article Title: A HPLC-fluorescence detection method for determination of cardiac phospholipase D activity in vitro. Article Snippet: l phospholipase D (PLD) activity in cardiac membranes has been developed.. A fluorescent derivative of phosphatidylcholine [2-decanoyl-1-(O-(11-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene3proprionyl)amino) undecyl) sn-glycero-3-phosphocholine] was utilized as substrate in an in vitro PLD-catalyzed transphosphatidylation reaction utilizing ethanol as second substrate.. Unreacted phosphatidylcholine and the products of phospholipase activity (PEtOH, phosphatidylethanol; PA, phosphatidic acid; DAG, diacylglycerol) were separated by a binary gradient HPLC system and detected by fluorometry. Article Title: Displacement chromatography using the UNO continuous bed column as a stationary phase Article Snippet: Displacement separations of biopolymers are even more restricted in regard to the upper applicable limit of the flow rate than elution chromatographic ones, when conventional columns packed with porous particles are used.. Bio-Rad has recently introduced a new column type, the UNO column, which contrary to conventional HPLC columns is not packed with particles but consists of a continuous porous polymer rod.. The plate height of this continuous bed column was found to be nearly independent of the flow rate within the investigated range (0.01-4.5 mL/min, 1.56-701.6 cm/h). Article Title: Adrenergic activation of cardiac phospholipase D: role of alpha(1)-adrenoceptor subtypes. Article Snippet: .. Influence of adrenergic receptor blocking agents The detector signal was recorded and integrated by a personal computer and a Software:Article Title: A HPLC-fluorescence detection method for determination of cardiac phospholipase D activity in vitro. Article Snippet: l phospholipase D (PLD) activity in cardiac membranes has been developed.. A fluorescent derivative of phosphatidylcholine [2-decanoyl-1-(O-(11-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene3proprionyl)amino) undecyl) sn-glycero-3-phosphocholine] was utilized as substrate in an in vitro PLD-catalyzed transphosphatidylation reaction utilizing ethanol as second substrate.. Unreacted phosphatidylcholine and the products of phospholipase activity (PEtOH, phosphatidylethanol; PA, phosphatidic acid; DAG, diacylglycerol) were separated by a binary gradient HPLC system and detected by fluorometry. Article Title: Displacement chromatography using the UNO continuous bed column as a stationary phase Article Snippet: Displacement separations of biopolymers are even more restricted in regard to the upper applicable limit of the flow rate than elution chromatographic ones, when conventional columns packed with porous particles are used.. Bio-Rad has recently introduced a new column type, the UNO column, which contrary to conventional HPLC columns is not packed with particles but consists of a continuous porous polymer rod.. The plate height of this continuous bed column was found to be nearly independent of the flow rate within the investigated range (0.01-4.5 mL/min, 1.56-701.6 cm/h). Article Title: Adrenergic activation of cardiac phospholipase D: role of alpha(1)-adrenoceptor subtypes. Article Snippet: .. Influence of adrenergic receptor blocking agents The detector signal was recorded and integrated by a personal computer and a Blocking Assay:Article Title: Adrenergic activation of cardiac phospholipase D: role of alpha(1)-adrenoceptor subtypes. Article Snippet: .. Influence of adrenergic receptor blocking agents The detector signal was recorded and integrated by a personal computer and a other:Article Title: Equipment news Article Snippet: Luminescence Spectrometers The Model LS-30 is a sensitive, rapid sampling luminescence spectrometer.. Maximum sensitivity is ensured by a compact dual monochromator system.. The illuminated flow cell is self-aligning and can be easily removed for maintenance. Article Title: On-line and off-line monitoring of the production of cephalosporin C by Acremonium chrysogenum. Article Snippet: Process monitoring of cephalosporin C formation by Acremonium chrysogenum in laboratory investigations is considered.. The goal of these investigations is the identification of bottlenecks in the biosynthesis and the improvement of the process performance.. Based on reports of other research groups and own experience the key parameters were selected, which influence the process performance. |