22-electrode array of the cochlear cochlear implant (Cochlear Limited)
90
Structured Review
Cochlear Limited
22-electrode array of the cochlear cochlear implant
22 Electrode Array Of The Cochlear Cochlear Implant, supplied by Cochlear Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22-electrode+array+of+the+cochlear+cochlear+implant/22+electrode+cochlear+implant/pm10641663-0-10-14
Average 90 stars, based on 1 article reviews
22 Electrode Array Of The Cochlear Cochlear Implant, supplied by Cochlear Limited, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/22-electrode+array+of+the+cochlear+cochlear+implant/22+electrode+cochlear+implant/pm10641663-0-10-14
Average 90 stars, based on 1 article reviews
22-electrode array of the cochlear cochlear implant - by Bioz Stars,
2026-11
90/100 stars
Images
Related Articles
other:Article Title: Biomedical studies on temporal bones of the first multi-channel cochlear implant patient at the University of Melbourne Article Snippet: Department of Otolaryngology, University of Melbourne and Eye & Ear Hospital, Melbourne, Australia, Centre for Neural Engineering, The University of Melbourne; Department of Otolaryngology, University of Melbourne and The Royal Victorian Eye & Ear Hospital, Melbourne, Australia, Department of Anatomy and Neuroscience, University of Melbourne, The Australian Phenomics Network Histopathology and Organ Pathology Service, Australia, The Australian Phenomics Network Histopathology and Organ Pathology Service, Melbourne, Australia, Departments of Physics & Psychology, La Trobe University, Melbourne, Australia, Department of Materials Science, Monash University, Bio21 Electron Microscope Unit, University of Melbourne, Australia, CRC Hear, Melbourne, Australia, The Bionics Institute, Melbourne, Australia, Departments of Pathology & Otolaryngology, Box Hill Hospital, Melbourne, Australia, Cochlear Corporation, Sydney, Australia, Department of Anatomical Pathology, Austin Hospital, University of Melbourne, Australia Article Title: The evolving science of cochlear implants. Article Snippet: In 1978, the first multichannel cochlear implant was developed in Australia and a prototype was surgically implanted in a 48-year-old patient (MC-1).. After a series of clinical trials, the US Food and Drug Administration approved the use of the Australian cochlear implant in adults in 1985, and subsequently, the agency has approved the device for use in infants as young as 6 months of age.. During the past 3 decades, more than 300 000 patients have had their hearing restored with cochlear implants. Article Title: Femtosecond laser hierarchical surface restructuring for next generation neural interfacing electrodes and microelectrode arrays Article Snippet: Figure 2 ( a ) Typical two-column spinal cord stimulation paddle electrode arrays with 8 and 16 electrodes (photo reproduced with permission from Bradley, K. Pain Medicine 7, 2006 ); ( b ) a leadless pacemaker that is implanted directly into the heart where the anode is a circumferential ring located in the proximal portion of the device and responsible for cardiac pacing (photo with permission and courtesy of Medtronic); ( c ) a cochlear implant electrode array with 22 Article Title: Spiral ganglion neuron survival and function in the deafened cochlea following chronic neurotrophic treatment Article Snippet: Environmentally-derived stimuli were delivered to the electrode array via an ESPrit 3G speech processor and Article Title: Effects of rate and age in processing interaural time and level differences in normal-hearing and bilateral cochlear-implant listeners Article Snippet: All BICI listeners were implanted with |