endopredict Search Results


90
Clinical and Laboratory Standards Institute endopredict multianalyte gene expression assay
RNA input range and reproducibility of <t>EndoPredict.</t> ( A ) EP scores depending on amount of input RNA. RNAs from 6 different FFPE samples were diluted and EP scores were assessed dependent on RNA input (C q -ARG as surrogate marker). 95% confidence intervals (CI) of EP scores calculated from the noise model are indicated. ( B ) Correlation between C q -ARG and total RNA concentration assessed by RIBOGREEN assay. Lower RNA input limit is indicated by dotted lines. ( C ) Reproducibility of 160 EP scores assessed in three different RNA samples (low risk, close to the decision point, high risk) over time (11 different working days distributed over 21 calendar days). Individual EP measurement results are indicated by dots.
Endopredict Multianalyte Gene Expression Assay, supplied by Clinical and Laboratory Standards Institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict+multianalyte+gene+expression+assay/pmc03534340-76-5-18
Average 90 stars, based on 1 article reviews
endopredict multianalyte gene expression assay - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sividon Diagnostics GmbH endopredict
RNA input range and reproducibility of <t>EndoPredict.</t> ( A ) EP scores depending on amount of input RNA. RNAs from 6 different FFPE samples were diluted and EP scores were assessed dependent on RNA input (C q -ARG as surrogate marker). 95% confidence intervals (CI) of EP scores calculated from the noise model are indicated. ( B ) Correlation between C q -ARG and total RNA concentration assessed by RIBOGREEN assay. Lower RNA input limit is indicated by dotted lines. ( C ) Reproducibility of 160 EP scores assessed in three different RNA samples (low risk, close to the decision point, high risk) over time (11 different working days distributed over 21 calendar days). Individual EP measurement results are indicated by dots.
Endopredict, supplied by Sividon Diagnostics GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict/pm26867046-820-10-14
Average 90 stars, based on 1 article reviews
endopredict - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sividon Diagnostics GmbH endopredict tests
<t>EndoPredict</t> test results achieved after different storage times and temperatures before fixation. The solid line represents the reference score which was derived from the mean EP score of the tissue sections that have been stored for 10 min at 20 °C before fixation. Dotted lines represent the reference score ±3× its standard deviation as determined by precision study . Measurements were performed in duplicate ( n = 2). Mean values are presented, with standard errors of the means indicated by bars
Endopredict Tests, supplied by Sividon Diagnostics GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict+test/pmc04180906-115-0-2
Average 90 stars, based on 1 article reviews
endopredict tests - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Myriad International GmbH endopredict gene expression assay
<t>EndoPredict</t> test results achieved after different storage times and temperatures before fixation. The solid line represents the reference score which was derived from the mean EP score of the tissue sections that have been stored for 10 min at 20 °C before fixation. Dotted lines represent the reference score ±3× its standard deviation as determined by precision study . Measurements were performed in duplicate ( n = 2). Mean values are presented, with standard errors of the means indicated by bars
Endopredict Gene Expression Assay, supplied by Myriad International GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict+gene+expression+assay/pmc08763835-43-1-5
Average 90 stars, based on 1 article reviews
endopredict gene expression assay - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Myriad International GmbH endopredict assays
Flowchart demonstrating <t>EndoPredict</t> test results and final tumor board recommendations
Endopredict Assays, supplied by Myriad International GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict+assays/pmc07584549-67-0-2
Average 90 stars, based on 1 article reviews
endopredict assays - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sividon Diagnostics GmbH reagents for the endopredict analysis
Flowchart demonstrating <t>EndoPredict</t> test results and final tumor board recommendations
Reagents For The Endopredict Analysis, supplied by Sividon Diagnostics GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/12+gene+risk+score+endopredict/pmc05574574-138-4-9
Average 90 stars, based on 1 article reviews
reagents for the endopredict analysis - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Myriad International GmbH endopredict
Characteristics of patients per type of therapy.
Endopredict, supplied by Myriad International GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict/pmc09377752-75-8-9
Average 90 stars, based on 1 article reviews
endopredict - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
NSABP Foundation endopredict
Characteristics of patients per type of therapy.
Endopredict, supplied by NSABP Foundation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict/pmc03859151-286-20-21
Average 90 stars, based on 1 article reviews
endopredict - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
CH Instruments endopredict
<t>EndoPredict</t> ® determination and allocation
Endopredict, supplied by CH Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict/pmc07275019-139-9-16
Average 90 stars, based on 1 article reviews
endopredict - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Anwendung GmbH endopredict
<t>EndoPredict</t> ® determination and allocation
Endopredict, supplied by Anwendung GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict/10__1159_slash_000312558-37-0-6
Average 90 stars, based on 1 article reviews
endopredict - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sividon Diagnostics GmbH endopredict® risk score
<t>EndoPredict</t> ® determination and allocation
Endopredict® Risk Score, supplied by Sividon Diagnostics GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict++risk+score/pm27031354-138-1-3
Average 90 stars, based on 1 article reviews
endopredict® risk score - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Sividon Diagnostics GmbH endopredict (ep) sividon
<t>EndoPredict</t> ® determination and allocation
Endopredict (Ep) Sividon, supplied by Sividon Diagnostics GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/endopredict/endopredict++ep++sividon/pm25848913-143-1-3
Average 90 stars, based on 1 article reviews
endopredict (ep) sividon - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


RNA input range and reproducibility of EndoPredict. ( A ) EP scores depending on amount of input RNA. RNAs from 6 different FFPE samples were diluted and EP scores were assessed dependent on RNA input (C q -ARG as surrogate marker). 95% confidence intervals (CI) of EP scores calculated from the noise model are indicated. ( B ) Correlation between C q -ARG and total RNA concentration assessed by RIBOGREEN assay. Lower RNA input limit is indicated by dotted lines. ( C ) Reproducibility of 160 EP scores assessed in three different RNA samples (low risk, close to the decision point, high risk) over time (11 different working days distributed over 21 calendar days). Individual EP measurement results are indicated by dots.

Journal: BMC Cancer

Article Title: Decentral gene expression analysis: analytical validation of the Endopredict genomic multianalyte breast cancer prognosis test

doi: 10.1186/1471-2407-12-456

Figure Lengend Snippet: RNA input range and reproducibility of EndoPredict. ( A ) EP scores depending on amount of input RNA. RNAs from 6 different FFPE samples were diluted and EP scores were assessed dependent on RNA input (C q -ARG as surrogate marker). 95% confidence intervals (CI) of EP scores calculated from the noise model are indicated. ( B ) Correlation between C q -ARG and total RNA concentration assessed by RIBOGREEN assay. Lower RNA input limit is indicated by dotted lines. ( C ) Reproducibility of 160 EP scores assessed in three different RNA samples (low risk, close to the decision point, high risk) over time (11 different working days distributed over 21 calendar days). Individual EP measurement results are indicated by dots.

Article Snippet: Here, we analytically validated the EndoPredict multianalyte gene expression assay according to the adapted guideline MM17-A of the Clinical and Laboratory Standards Institute (CLSI) addressing the analytical validation of nucleic acid-based qualitative and semiquantitative multiplex assays [ ].

Techniques: Marker, Concentration Assay

EndoPredict test results achieved after different storage times and temperatures before fixation. The solid line represents the reference score which was derived from the mean EP score of the tissue sections that have been stored for 10 min at 20 °C before fixation. Dotted lines represent the reference score ±3× its standard deviation as determined by precision study . Measurements were performed in duplicate ( n = 2). Mean values are presented, with standard errors of the means indicated by bars

Journal: Virchows Archiv

Article Title: Preanalytical variables and performance of diagnostic RNA-based gene expression analysis in breast cancer

doi: 10.1007/s00428-014-1652-0

Figure Lengend Snippet: EndoPredict test results achieved after different storage times and temperatures before fixation. The solid line represents the reference score which was derived from the mean EP score of the tissue sections that have been stored for 10 min at 20 °C before fixation. Dotted lines represent the reference score ±3× its standard deviation as determined by precision study . Measurements were performed in duplicate ( n = 2). Mean values are presented, with standard errors of the means indicated by bars

Article Snippet: EndoPredict tests (Sividon Diagnostics, Cologne, Germany) were performed as previously described using SuperScript III PLATINUM One-Step Quantitative RT-PCR System (Life Technologies, Darmstadt, Germany) and VERSANT kPCR Molecular System (Siemens Healthcare Diagnostics, Tarrytown, USA) [ , ].

Techniques: Derivative Assay, Standard Deviation

EndoPredict test results achieved after different fixation times. The solid line represents the reference score which was derived from the mean EP score of the tissue sections that have been fixed for 20 h in neutral buffered formalin. Dotted lines represent the reference score ±3× its standard deviation as determined by precision study . Measurements were performed in duplicate ( n = 2). Mean values are presented, with standard errors of the means indicated by bars

Journal: Virchows Archiv

Article Title: Preanalytical variables and performance of diagnostic RNA-based gene expression analysis in breast cancer

doi: 10.1007/s00428-014-1652-0

Figure Lengend Snippet: EndoPredict test results achieved after different fixation times. The solid line represents the reference score which was derived from the mean EP score of the tissue sections that have been fixed for 20 h in neutral buffered formalin. Dotted lines represent the reference score ±3× its standard deviation as determined by precision study . Measurements were performed in duplicate ( n = 2). Mean values are presented, with standard errors of the means indicated by bars

Article Snippet: EndoPredict tests (Sividon Diagnostics, Cologne, Germany) were performed as previously described using SuperScript III PLATINUM One-Step Quantitative RT-PCR System (Life Technologies, Darmstadt, Germany) and VERSANT kPCR Molecular System (Siemens Healthcare Diagnostics, Tarrytown, USA) [ , ].

Techniques: Derivative Assay, Standard Deviation

Correlation of the relative expression values of the  EndoPredict  genes of interest between whole sections and manually microdissected sections

Journal: Virchows Archiv

Article Title: Preanalytical variables and performance of diagnostic RNA-based gene expression analysis in breast cancer

doi: 10.1007/s00428-014-1652-0

Figure Lengend Snippet: Correlation of the relative expression values of the EndoPredict genes of interest between whole sections and manually microdissected sections

Article Snippet: EndoPredict tests (Sividon Diagnostics, Cologne, Germany) were performed as previously described using SuperScript III PLATINUM One-Step Quantitative RT-PCR System (Life Technologies, Darmstadt, Germany) and VERSANT kPCR Molecular System (Siemens Healthcare Diagnostics, Tarrytown, USA) [ , ].

Techniques: Expressing

Correlation between the EP ( a ) and EPclin ( b ) scores of paired whole and tumor-enriched, manually microdissected tissue sections from ER+/HER2− breast cancer patients ( n = 39). Pearson correlation coefficient of EP scores was 0.97 with a concordance of EndoPredict risk classification of 87 %. Pearson correlation coefficient of EPclin scores was 0.98 with a concordance of EndoPredict risk classification of 95 %. Black filled circles represent tissue samples with TCC ≥30 %, open circles tissue sections with TCC <30 %

Journal: Virchows Archiv

Article Title: Preanalytical variables and performance of diagnostic RNA-based gene expression analysis in breast cancer

doi: 10.1007/s00428-014-1652-0

Figure Lengend Snippet: Correlation between the EP ( a ) and EPclin ( b ) scores of paired whole and tumor-enriched, manually microdissected tissue sections from ER+/HER2− breast cancer patients ( n = 39). Pearson correlation coefficient of EP scores was 0.97 with a concordance of EndoPredict risk classification of 87 %. Pearson correlation coefficient of EPclin scores was 0.98 with a concordance of EndoPredict risk classification of 95 %. Black filled circles represent tissue samples with TCC ≥30 %, open circles tissue sections with TCC <30 %

Article Snippet: EndoPredict tests (Sividon Diagnostics, Cologne, Germany) were performed as previously described using SuperScript III PLATINUM One-Step Quantitative RT-PCR System (Life Technologies, Darmstadt, Germany) and VERSANT kPCR Molecular System (Siemens Healthcare Diagnostics, Tarrytown, USA) [ , ].

Techniques:

Mean difference of relative expression values (delta Cq value [nonstored]-delta Cq value [stored]) of the  EndoPredict  genes of interest between nonstored and stored FFPE tissue sections

Journal: Virchows Archiv

Article Title: Preanalytical variables and performance of diagnostic RNA-based gene expression analysis in breast cancer

doi: 10.1007/s00428-014-1652-0

Figure Lengend Snippet: Mean difference of relative expression values (delta Cq value [nonstored]-delta Cq value [stored]) of the EndoPredict genes of interest between nonstored and stored FFPE tissue sections

Article Snippet: EndoPredict tests (Sividon Diagnostics, Cologne, Germany) were performed as previously described using SuperScript III PLATINUM One-Step Quantitative RT-PCR System (Life Technologies, Darmstadt, Germany) and VERSANT kPCR Molecular System (Siemens Healthcare Diagnostics, Tarrytown, USA) [ , ].

Techniques: Expressing

Correlation of EP scores between stored and nonstored FFPE tissue sections. EP scores have been determined at the beginning of the study, after 12 months at +4 °C ( a ) or after 12 months at +20 °C ( b ), respectively. Pearson correlation coefficients were 0.99 and >0.99 with a concordance of EndoPredict risk classification of 100 %

Journal: Virchows Archiv

Article Title: Preanalytical variables and performance of diagnostic RNA-based gene expression analysis in breast cancer

doi: 10.1007/s00428-014-1652-0

Figure Lengend Snippet: Correlation of EP scores between stored and nonstored FFPE tissue sections. EP scores have been determined at the beginning of the study, after 12 months at +4 °C ( a ) or after 12 months at +20 °C ( b ), respectively. Pearson correlation coefficients were 0.99 and >0.99 with a concordance of EndoPredict risk classification of 100 %

Article Snippet: EndoPredict tests (Sividon Diagnostics, Cologne, Germany) were performed as previously described using SuperScript III PLATINUM One-Step Quantitative RT-PCR System (Life Technologies, Darmstadt, Germany) and VERSANT kPCR Molecular System (Siemens Healthcare Diagnostics, Tarrytown, USA) [ , ].

Techniques:

Flowchart demonstrating EndoPredict test results and final tumor board recommendations

Journal: Archives of Gynecology and Obstetrics

Article Title: First prospective outcome data for the second-generation multigene test Endopredict in ER-positive/HER2-negative breast cancer

doi: 10.1007/s00404-020-05771-4

Figure Lengend Snippet: Flowchart demonstrating EndoPredict test results and final tumor board recommendations

Article Snippet: EndoPredict assays (Myriad International GmbH, Cologne, Germany) were performed on FFPE tissue samples of primary breast tumours in the Institute of Pathology at Klinikum rechts der Isar, Technical University Munich, according to the manufacturer’s instructions as described previously [ ].

Techniques:

Characteristics of patients per type of therapy.

Journal: Clinical Cancer Research

Article Title: Persistence of ctDNA in Patients with Breast Cancer During Neoadjuvant Treatment Is a Significant Predictor of Poor Tumor Response

doi: 10.1158/1078-0432.CCR-21-3231

Figure Lengend Snippet: Characteristics of patients per type of therapy.

Article Snippet: A subset of diagnostic cores was tested using EndoPredict (Myriad International GmbH) at the University of Vienna according to manufacturer's instructions as previously described ( ).

Techniques: Clinical Proteomics

Association between circulating tumor DNA and clinicopathologic characteristics. A, Association between ctDNA presence (ctDNA+) and absence (ctDNA−) at baseline and clinicopathologic characteristics. P values were calculated using Fisher exact test. B, Distribution of tumor size, Ki-67 scores, EndoPredict scores (MS, 12-gene molecular score; EPclin, combined clinic-molecular score), and stromal and intratumoral TILs in patients with (ctDNA+) and without (ctDNA−) detectable ctDNA at baseline.

Journal: Clinical Cancer Research

Article Title: Persistence of ctDNA in Patients with Breast Cancer During Neoadjuvant Treatment Is a Significant Predictor of Poor Tumor Response

doi: 10.1158/1078-0432.CCR-21-3231

Figure Lengend Snippet: Association between circulating tumor DNA and clinicopathologic characteristics. A, Association between ctDNA presence (ctDNA+) and absence (ctDNA−) at baseline and clinicopathologic characteristics. P values were calculated using Fisher exact test. B, Distribution of tumor size, Ki-67 scores, EndoPredict scores (MS, 12-gene molecular score; EPclin, combined clinic-molecular score), and stromal and intratumoral TILs in patients with (ctDNA+) and without (ctDNA−) detectable ctDNA at baseline.

Article Snippet: A subset of diagnostic cores was tested using EndoPredict (Myriad International GmbH) at the University of Vienna according to manufacturer's instructions as previously described ( ).

Techniques:

EndoPredict ® determination and allocation

Journal: Breast Cancer Research and Treatment

Article Title: EndoPredict ® in early hormone receptor-positive, HER2-negative breast cancer

doi: 10.1007/s10549-020-05688-1

Figure Lengend Snippet: EndoPredict ® determination and allocation

Article Snippet: Comparisons between clinico-pathological factors and the results of the EndoPredict ® were calculated using the Pearson's chi-squared test ( χ 2 -test) and Fisher’s exact test.

Techniques:

Associations between  EndoPredict  ® and clinico-pathological characteristics ( n = 869)

Journal: Breast Cancer Research and Treatment

Article Title: EndoPredict ® in early hormone receptor-positive, HER2-negative breast cancer

doi: 10.1007/s10549-020-05688-1

Figure Lengend Snippet: Associations between EndoPredict ® and clinico-pathological characteristics ( n = 869)

Article Snippet: Comparisons between clinico-pathological factors and the results of the EndoPredict ® were calculated using the Pearson's chi-squared test ( χ 2 -test) and Fisher’s exact test.

Techniques:

Influence of clinico-pathological factors on the use of  EndoPredict  ® (multivariate analysis)

Journal: Breast Cancer Research and Treatment

Article Title: EndoPredict ® in early hormone receptor-positive, HER2-negative breast cancer

doi: 10.1007/s10549-020-05688-1

Figure Lengend Snippet: Influence of clinico-pathological factors on the use of EndoPredict ® (multivariate analysis)

Article Snippet: Comparisons between clinico-pathological factors and the results of the EndoPredict ® were calculated using the Pearson's chi-squared test ( χ 2 -test) and Fisher’s exact test.

Techniques:

Association between  EndoPredict  ® result and patient and tumor characteristics ( n = 156)

Journal: Breast Cancer Research and Treatment

Article Title: EndoPredict ® in early hormone receptor-positive, HER2-negative breast cancer

doi: 10.1007/s10549-020-05688-1

Figure Lengend Snippet: Association between EndoPredict ® result and patient and tumor characteristics ( n = 156)

Article Snippet: Comparisons between clinico-pathological factors and the results of the EndoPredict ® were calculated using the Pearson's chi-squared test ( χ 2 -test) and Fisher’s exact test.

Techniques: