Review





Similar Products

90
MIM Software Inc petedge tool of mim software
Petedge Tool Of Mim Software, supplied by MIM Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/pet+edge+tool/pm40167887-69-10-12
Average 90 stars, based on 1 article reviews
petedge tool of mim software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIM Software Inc gradient-based technique (petedge + tool)
Gradient Based Technique (Petedge + Tool), supplied by MIM Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/gradient+based+segmentation+method+pet+edge/pm37148355-57-49-56
Average 90 stars, based on 1 article reviews
gradient-based technique (petedge + tool) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIMVista corp petedge tool
Petedge Tool, supplied by MIMVista corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/petedge+tool/pm34729628-86-11-14
Average 90 stars, based on 1 article reviews
petedge tool - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIMVista corp mimvista petedge tool
Mimvista Petedge Tool, supplied by MIMVista corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/petedge+tool+of+the+mimvista+software/pm31551134-57-28-27
Average 90 stars, based on 1 article reviews
mimvista petedge tool - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIM Software Inc gradient-based, petedge tool of the mim software
Gradient Based, Petedge Tool Of The Mim Software, supplied by MIM Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/gradient+based+segmentation+method+pet+edge/pmc06286257-272-30-37
Average 90 stars, based on 1 article reviews
gradient-based, petedge tool of the mim software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIM Software Inc gradient-based, petedge tool
Gradient Based, Petedge Tool, supplied by MIM Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/gradient+based++petedge+tool/pmc06286257-235-35-42
Average 90 stars, based on 1 article reviews
gradient-based, petedge tool - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
MIMVista corp petedge tool in mimvista software
Agreement between MTVs and actual volumes in NEMA IQ phantom
Petedge Tool In Mimvista Software, supplied by MIMVista corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/petedge+tool/petedge+tool+of+the+mimvista+software/pmc06334209-124-16-19
Average 90 stars, based on 1 article reviews
petedge tool in mimvista software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Agreement between MTVs and actual volumes in NEMA IQ phantom

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: Agreement between MTVs and actual volumes in NEMA IQ phantom

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques:

Representative NEMA IQ phantom PET image to compare accuracy between segmentation methods. A. In LBR 1.5:1, MO-PET and PETedge showed relatively accurate segmentation in three largest lesions in the phantom (diameter = 3.7, 2.8 and 2.2 cm) but 60% relative threshold overestimated the volumes in two lesions with diameters of 2.8 and 2.2 cm. B. In LBR 4:1 phantom, MO-PET (light blue colored ROI), and 60% relative threshold (green colored ROI) showed relatively accurate segmentation in two smallest lesions (diameter = 1.3, and 1 cm). However, PETedge (pink colored ROI) underestimated the actual volume of the two lesions. Upper row: CT, middle row: PET, lower row: PET/CT.

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: Representative NEMA IQ phantom PET image to compare accuracy between segmentation methods. A. In LBR 1.5:1, MO-PET and PETedge showed relatively accurate segmentation in three largest lesions in the phantom (diameter = 3.7, 2.8 and 2.2 cm) but 60% relative threshold overestimated the volumes in two lesions with diameters of 2.8 and 2.2 cm. B. In LBR 4:1 phantom, MO-PET (light blue colored ROI), and 60% relative threshold (green colored ROI) showed relatively accurate segmentation in two smallest lesions (diameter = 1.3, and 1 cm). However, PETedge (pink colored ROI) underestimated the actual volume of the two lesions. Upper row: CT, middle row: PET, lower row: PET/CT.

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques: Positron Emission Tomography-Computed Tomography

MO-PET and PETedge segmentation in a patient with osteosarcoma. Repeated independent measurements using MO-PET (blue and light blue colored ROIs) and PETedge (red and pink colored ROIs) showed excellent intra-method agreements with the minor discrepancy. Note that the tumor portion with a low FDG uptake was included in PETedge segmentation but excluded in MO-PET segmentation.

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: MO-PET and PETedge segmentation in a patient with osteosarcoma. Repeated independent measurements using MO-PET (blue and light blue colored ROIs) and PETedge (red and pink colored ROIs) showed excellent intra-method agreements with the minor discrepancy. Note that the tumor portion with a low FDG uptake was included in PETedge segmentation but excluded in MO-PET segmentation.

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques:

Intra-class correlation and Bland-Altman analysis of measurements using MO-PET and  PETedge  segmentation

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: Intra-class correlation and Bland-Altman analysis of measurements using MO-PET and PETedge segmentation

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques:

Bland-Altman plot for repeated measurement using MO-PET and PETedge. Repeated measurements of MTV, SUVmean, and TLG using (A) MO-PET and (B) PETedge showed excellent agreements. (C) However, measurements of MTV, SUVmean, and TLG between MO-PET and PETedge showed substantial variation.

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: Bland-Altman plot for repeated measurement using MO-PET and PETedge. Repeated measurements of MTV, SUVmean, and TLG using (A) MO-PET and (B) PETedge showed excellent agreements. (C) However, measurements of MTV, SUVmean, and TLG between MO-PET and PETedge showed substantial variation.

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques:

Event free survival time and hazard ratio

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: Event free survival time and hazard ratio

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques:

Prediction of event free survival (EFS) using MTV (MO-PET) and MTV (PETedge). (A) ROC curves of MTV (MO-PET) and MTV (PETedge) for prediction of the event at two years. MTV (MO-PET) and MTV (PETedge) showed the similar area under curve (AUC) of 0.771, 0.781 respectively for prediction of the event at two years. Kaplan-Meyer curves between low and high MTV groups classified by (B) MTV (MO-PET) and (C) MTV (PETedge). (D) EFS was longest in low MTV group followed by high MTV (MO-PET or PETedge) group and high MTV (MO-PET and PETedge) group (P for trend = 0.0002). Low MTV (MO PET and PETedge) = patient group with low MTV by MTV (MO-PET) and MTV (PETedge), high MTV (MO-PET or PETedge) = patient group with high MTV by either MTV (MO-PET) or MTV (PETedge), high MTV (MO-PET and PETedge) = patient group with high MTV by both MTV (MO-PET) and MTV (PETedge).

Journal: American Journal of Nuclear Medicine and Molecular Imaging

Article Title: Multi-level otsu method to define metabolic tumor volume in positron emission tomography

doi:

Figure Lengend Snippet: Prediction of event free survival (EFS) using MTV (MO-PET) and MTV (PETedge). (A) ROC curves of MTV (MO-PET) and MTV (PETedge) for prediction of the event at two years. MTV (MO-PET) and MTV (PETedge) showed the similar area under curve (AUC) of 0.771, 0.781 respectively for prediction of the event at two years. Kaplan-Meyer curves between low and high MTV groups classified by (B) MTV (MO-PET) and (C) MTV (PETedge). (D) EFS was longest in low MTV group followed by high MTV (MO-PET or PETedge) group and high MTV (MO-PET and PETedge) group (P for trend = 0.0002). Low MTV (MO PET and PETedge) = patient group with low MTV by MTV (MO-PET) and MTV (PETedge), high MTV (MO-PET or PETedge) = patient group with high MTV by either MTV (MO-PET) or MTV (PETedge), high MTV (MO-PET and PETedge) = patient group with high MTV by both MTV (MO-PET) and MTV (PETedge).

Article Snippet: The lesions in the phantom were segmented using 4 approaches: 1) MO-PET, 2) gradient-based method using PETedge tool in MIMvista software, 3) conventional threshold methods which are relative threshold methods (20%, 40%, 60%, or 80% of the maximum activity), and 4) four background threshold methods (mean background +1 or +2 standard deviations, and mean background × 2 or × 2.5).

Techniques: