|
NeuroNexus Technologies
peripheral nerve cuffs Peripheral Nerve Cuffs, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/custom%40peripheral-nerve-cuffs%4010%2E1523%2Fjneurosci%2E0651-25%2E2025 Average 94 stars, based on 1 article reviews
peripheral nerve cuffs - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
NeuroNexus Technologies
polyimide 30 channels eeg electrode array ![]() Polyimide 30 Channels Eeg Electrode Array, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/pmc11035371-271-1-8 Average 94 stars, based on 1 article reviews
polyimide 30 channels eeg electrode array - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
NeuroNexus Technologies
h32 ![]() H32, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/pmc11035371-37-7-4 Average 94 stars, based on 1 article reviews
h32 - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
NeuroNexus Technologies
eeg electrode array ![]() Eeg Electrode Array, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/pmc11035371-37-0-4 Average 94 stars, based on 1 article reviews
eeg electrode array - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
NeuroNexus Technologies
single shank silicon probe ![]() Single Shank Silicon Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/bio_rxiv__2023__09__26__558975-117-4-7 Average 94 stars, based on 1 article reviews
single shank silicon probe - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
NeuroNexus Technologies
4 shank h 32 silicon probe ![]() 4 Shank H 32 Silicon Probe, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/pm36731682-51-6-10 Average 94 stars, based on 1 article reviews
4 shank h 32 silicon probe - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
NeuroNexus Technologies
buzsaki32 h32 21 ![]() Buzsaki32 H32 21, supplied by NeuroNexus Technologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/Peripheral+Nerve+cuffs/pm32508613-165-24-23 Average 94 stars, based on 1 article reviews
buzsaki32 h32 21 - by Bioz Stars,
2026-11
94/100 stars
|
Buy from Supplier |
|
COMSOL Inc
fems of a compound peripheral nerve and cuff electrode comsol multiphysics v5.3 ![]() Fems Of A Compound Peripheral Nerve And Cuff Electrode Comsol Multiphysics V5.3, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/fems+of+a+compound+peripheral+nerve+and+cuff+electrode+comsol+multiphysics+v5+3/pmc07309635-217-13-12 Average 90 stars, based on 1 article reviews
fems of a compound peripheral nerve and cuff electrode comsol multiphysics v5.3 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Verlag GmbH
chronic implantable peripheral nerve cuff electrode ![]() Chronic Implantable Peripheral Nerve Cuff Electrode, supplied by Verlag GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/peripheral+nerve+cuffs/chronic+implantable+peripheral+nerve+cuff+electrode/10__1002_slash_adhm__201770029-46-46-12 Average 90 stars, based on 1 article reviews
chronic implantable peripheral nerve cuff electrode - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Journal: iScience
Article Title: The lactate receptor HCAR1: A key modulator of epileptic seizure activity
doi: 10.1016/j.isci.2024.109679
Figure Lengend Snippet:
Article Snippet: A
Techniques: Recombinant, Software
Journal: iScience
Article Title: The lactate receptor HCAR1: A key modulator of epileptic seizure activity
doi: 10.1016/j.isci.2024.109679
Figure Lengend Snippet:
Article Snippet: EEG electrode array ,
Techniques: Recombinant, Software
Journal: iScience
Article Title: The lactate receptor HCAR1: A key modulator of epileptic seizure activity
doi: 10.1016/j.isci.2024.109679
Figure Lengend Snippet: Spatial distribution of EEG power during seizures (A) Schematic representation of the EEG electrode array implant comprising 30 electrodes. (B) Example traces of 7 out of 30 channels. Detected seizure activity is highlighted in red in the traces. (C) Power of the different frequency bands for the average seizure in the WT and HCAR1-KO averaged over time and channels. Global (0-200Hz) : Means ± SEM: WT = 8.86 ± 1.47, HCAR1-KO = 13.67 ± 0.84, p = 0.0110. Delta (1-3Hz) : Means ± SEM: WT = 9.09 ± 3.70, HCAR1-KO = 19.85 ± 3.14, p = 0.0046. Theta (4-8Hz) : Means ± SEM: WT 9.540 ± 3.077, HCAR1-KO 21.44 ± 2.48, p = 0.0103. Alpha (9-13Hz) : Means ± SEM: WT = 8.88 ± 2.218, HCAR1-KO = 21.20 ± 2.104, p = 0.0019. Beta (14-30Hz) : Means ± SEM: WT = 9.005 ± 1.69, HCAR1-KO = 19.09 ± 1.62, p = 0.0012. Gamma (31-80Hz) : Means ± SEM: WT = 8.253 ± 1.313, HCAR1-KO = 14.12 ± 1.08 p = 0.004. HFO (80-200Hz) : Means ± SEM: WT = 9.07 ± 1.70, HCAR1-KO = 11.95 ± 0.80. p = 0.1228, unpaired t test, n = 6 WT, n = 8 HCAR1-KO. (D) Topographical maps of the average seizure in WT and HCAR1-KO mice showing the spread of the power through the brain according to frequency bands. Pseudocolors represent the power in dB of the frequency bands at each point in space. n = 6 WT, n = 8 HCAR1-KO.
Article Snippet:
Techniques: Activity Assay
Journal: iScience
Article Title: The lactate receptor HCAR1: A key modulator of epileptic seizure activity
doi: 10.1016/j.isci.2024.109679
Figure Lengend Snippet: HCAR1 agonists fail to modulate seizures in the intrahippocampal kainate injection model (A) Schematic representation of subdural electrode placement over the dorsal hippocampus and the craniotomies for kainate injection. Left: top view. Right: Coronal view depicting the injection points as red circles. (B) Image of the 3Cl-HBA injection point in the dentate gyrus after the injection of Evan’s blue dye. (C) Example trace of an EEG recording displaying typical seizure events. (D–F) Power of the frequencies in the ipsilateral and contralateral hemispheres during seizures for (D) Global (0-500Hz): Means ± SEM: saline ipsilateral = 13.74 ± 0.67, saline contralateral = 16.58 ± 1.59, 3Cl-HBA ipsilateral = 15.13 ± 1.21, 3Cl-HBA contralateral = 15.93 ± 1.42. p > 0.005. (E) Theta (4-8Hz): Means ± SEM: saline ipsilateral = 12.83 ± 0.81, saline contralateral = 15.50 ± 1.53, 3Cl-HBA ipsilateral = 14.05 ± 1.24, 3Cl-HBA contralateral = 14.30 ± 1.42. p > 0.005. (F) HFO (80-500Hz): Means ± SEM: saline ipsilateral = 7.53 ± 1.40, saline contralateral = 11.94 ± 3.59, 3Cl-HBA ipsilateral = 10.25 ± 0.99, 3Cl-HBA contralateral = 9.17 ± 1.24. p > 0.005. Two-way ANOVA n = 9 control, n = 10 3Cl-HBA (2.5mM).
Article Snippet:
Techniques: Injection, Saline, Control
Journal: iScience
Article Title: The lactate receptor HCAR1: A key modulator of epileptic seizure activity
doi: 10.1016/j.isci.2024.109679
Figure Lengend Snippet:
Article Snippet:
Techniques: Recombinant, Software