|
Fortis Life Sciences
antibodies against nup153 ![]() Antibodies Against Nup153, supplied by Fortis Life Sciences, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/NUP153+Antibody/pmc13183583-353-27-31 Average 93 stars, based on 1 article reviews
antibodies against nup153 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
ABclonal Biotechnology
anti nup153 monoclonal antibody ![]() Anti Nup153 Monoclonal Antibody, supplied by ABclonal Biotechnology, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/NUP153+Rabbit+mAb/pmc13325906-270-82-85 Average 94 stars, based on 1 article reviews
anti nup153 monoclonal antibody - by Bioz Stars,
2026-10
94/100 stars
|
Buy from Supplier |
|
Proteintech
anti nup153 ![]() Anti Nup153, supplied by Proteintech, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/NUP153+Antibody/pm41677375-267-56-57 Average 93 stars, based on 1 article reviews
anti nup153 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Proteintech
nup153 ![]() Nup153, supplied by Proteintech, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/NUP153+Antibody/pm41575851-660-12-24 Average 93 stars, based on 1 article reviews
nup153 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Santa Cruz Biotechnology
nup153 ![]() Nup153, supplied by Santa Cruz Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/Nup153+Antibody/pm41575851-660-12-19 Average 93 stars, based on 1 article reviews
nup153 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Addgene inc
pegfp c3 nup153 ![]() Pegfp C3 Nup153, supplied by Addgene inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/pEGFP(C3)-Nup153+(Plasmid+%2364268)/bio_rxiv__64898__2025__12__12__693814-295-13-14 Average 93 stars, based on 1 article reviews
pegfp c3 nup153 - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Proteintech
ab170940 anti nup153 antibody ![]() Ab170940 Anti Nup153 Antibody, supplied by Proteintech, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/NUP153+Antibody/pmc12480842__41467_2025_63700_MOESM4_ESM-63-49-53 Average 93 stars, based on 1 article reviews
ab170940 anti nup153 antibody - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
Proteintech
1 ap anti flag antibody ![]() 1 Ap Anti Flag Antibody, supplied by Proteintech, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/NUP153+Antibody/pmc12480842__41467_2025_63700_MOESM4_ESM-63-57-69 Average 93 stars, based on 1 article reviews
1 ap anti flag antibody - by Bioz Stars,
2026-10
93/100 stars
|
Buy from Supplier |
|
GenScript corporation
nup153 peptide ![]() Nup153 Peptide, supplied by GenScript corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/nup153/nup+153+peptide+1407+tnnspsgvftfgansst+1423/pmc10068764__pnas__2202815120__sapp-57-1-3 Average 90 stars, based on 1 article reviews
nup153 peptide - by Bioz Stars,
2026-10
90/100 stars
|
Buy from Supplier |
Journal: Nature Physics
Article Title: The local mechanostructural properties of protein cargoes regulate nucleocytoplasmic transport
doi: 10.1038/s41567-026-03242-2
Figure Lengend Snippet: ( A-C ) Nuclear import kinetics of the mCherry protein when imported from the N- or C-terminus upon downregulating Nup153. ( A ) Representative confocal images of U2OS cells after 20 min of the recovery phase, scale bar 10 µm. ( B ) Average time-courses of the nucleus-to-cytoplasm localisation of the “Import forward” and “Import reverse” mCherry in the control group ( siNT ) and knocking down Nup153 ( siNup153 ). ( C ) Relative nuclear accumulation (left) and import rate calculated from fits to the recovery time courses. Bars indicate mean. Accumulation: N-term ( siNT ) K e = 2.21 ± 0.07; N-term ( siNup153 ) K e = 1.00 ± 0.04; C-term ( siNT ) K e = 1.14 ± 0.03; C-term ( siNup153 ) K e = 0.83 ± 0.02. Import rate: N-term ( siNT ) k I = 3.95 ± 0.14 ks −1 ; N-term ( siNup153 ) k I = 1.59 ± 0.08 ks −1 ; C-term ( siNT ) k I = 0.83 ± 0.02 ks −1 ; C-term ( siNup153 ) k I = 1.13 ± 0.04 ks −1 . Significance levels for two-tailed Mann-Whitney non-parametric test. Accumulation: N-term ( siNT ) vs. C-term ( siNT ) P = 0; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = P = 4.00x10 −4 ; N-term ( siNT ) vs. N-term ( siNup153 ) P = 0; C-term ( siNT ) vs. C-term ( siNup153 ) P = 9.9x10 −12 . Import rate: N-term ( siNT ) vs. C-term ( siNT ) P = 0; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = 3.0x10 −6 ; N-term ( siNT ) vs. N-term ( siNup153 ) P = 0; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = 6.7x10 −16 . n = 103 ( siNT N-term); n = 100 ( siNT C-term); n = 85 ( siNUP153 N-term); n = 91 ( siNUP153 C-term). ( D-F ) Nuclear import kinetics of the Ig27 when imported from the N- or C- terminus upon downregulating Nup153. ( D ) Representative confocal images of U2OS cells after 20 min of the recovery phase, scale bar 10 µm. ( E ) Average time-courses of the nucleus-to-cytoplasm localisation of the “Import forward” and “Import reverse” Ig27 in the control group ( siNT ) and knocking down Nup153 ( siNup153 ). ( F ) Relative nuclear accumulation (left) and import rate calculated from fits to the recovery time courses. Bars indicate mean. Accumulation: N-term ( siNT ) K e = 1.43 ± 0.04; C-term ( siNT ) K e = 1.15 ± 0.03; N-term ( siNUP153 ) K e = 0.64 ± 0.02; C-term ( siNup153 ) K e = 0.64 ± 0.02. Import rate: N-term ( siNT ) k I = 1.63 ± 0.06 ks −1 ; C-term ( siNT ) k I = 0.97 ± 0.03 ks −1 ; N-term ( siNUP153 ) k I = 0.60 ± 0.02 ks −1 ; C-term ( siNup153 ) k I = 0.44 ± 0.02 ks −1 . Significance levels for two-tailed Mann-Whitney non-parametric test. Accumulation: N-term ( siNT ) vs. C-term ( siNT ) P = 5.2x10 −9 ; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = 0.71; N-term ( siNT ) vs. N-term ( siNup153 ) P = 0; C-term ( siNT ) vs. C-term ( siNup153 ) P = 0. Import rate: N-term ( siNT ) vs. C-term ( siNT ) P = 1.3x10 −13 ; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = 5.2x10 −8 ; N-term ( siNT ) vs. N-term ( siNup153 ) P = 0; C-term ( siNup153 ) vs. C-term ( siNT ) P = 0. n = 103 ( siNT N-term); n = 101 ( siNT C-term); n = 85 ( siNUP153 N-term); n = 91 ( siNUP153 C-term). ( G-I ) Nuclear import kinetics of the Spy0128 E117A when imported from the N- or C-terminus upon knocking down Nup153. ( G ) Representative confocal images of U2OS cells after 20 min of the recovery phase, scale bar 10 µm. ( H ) Average time-courses of the nucleus-to-cytoplasm localisation of the “Import forward” and “Import reverse” Spy0128 E117A in the control group ( siNT ) and knocking down Nup153 ( siNup153 ). ( I ) Relative nuclear accumulation (left) and import rate calculated from fits to the recovery time courses. Bars indicate mean. Accumulation: N-term ( siNT ) K e = 0.66 ± 0.22; C-term ( siNT ) K e = 0.54 ± 0.02; N-term ( siNUP153 ) K e = 0.40 ± 0.03; C-term ( siNup153 ) K e = 0.41 ± 0.06. Import rate: N-term ( siNT ) k I = 0.63 ± 0.03 ks −1 ; C-term ( siNT ) k I = 0.29 ± 0.02 ks −1 ; N-term ( siNUP153 ) k I = 0.34 ± 0.02 ks −1 ; C-term ( siNup153 ) k I = 0.16 ± 0.02 ks −1 . Significance levels for two-tailed Mann-Whitney non-parametric test. Accumulation: N-term ( siNT ) vs. C-term ( siNT ) P = 1.0x10 −3 ; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = 0.40; N-term ( siNT ) vs. N-term ( siNup153 ) P = 6.9x10 −10 ; C-term ( siNT ) vs. C-term ( siNup153 ) P = 4.8x10 −3 . Import rate: N-term ( siNT ) vs. C-term ( siNT ) P = 1.2x10 −13 ; N-term ( siNup153 ) vs. C-term ( siNup153 ) P = 4.9x10 −5 ; N-term ( siNT ) vs. N-term ( siNup153 ) P = 3.2x10 −11 ; C-term ( siNup153 ) vs. C-term ( siNT ) P = 1.0x10 −3 . n = 81 ( siNT N-term); n = 37 ( siNT C-term); n = 37 ( siNUP153 N-term); n = 10 ( siNUP153 C-term). ( J ) Percentage of directionality in nuclear accumulation (calculated as the ratio between the N-term and C-term accumulation) for the siNT control group and siNup153 . Error bars indicate SEM. ( K ) Schematics of the proposed role of NUP153 in sensing mechanically labile termini to accelerate nuclear transport.
Article Snippet: Membranes were incubated in a blocking buffer (5% skimmed milk powder in TBS containing 0.2% Tween-20) for 1 h at room temperature and then incubated overnight with
Techniques: Control, Two Tailed Test, MANN-WHITNEY