|
Nacalai
microchannels Microchannels, supplied by Nacalai, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannels/product/Nacalai Average 86 stars, based on 1 article reviews
microchannels - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Abaqus Inc
microchannel region Microchannel Region, supplied by Abaqus Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannel region/product/Abaqus Inc Average 86 stars, based on 1 article reviews
microchannel region - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Dow Corning
microchannel Microchannel, supplied by Dow Corning, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannel/product/Dow Corning Average 86 stars, based on 1 article reviews
microchannel - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Edinburgh Instruments
microchannel plate pmt Microchannel Plate Pmt, supplied by Edinburgh Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannel plate pmt/product/Edinburgh Instruments Average 86 stars, based on 1 article reviews
microchannel plate pmt - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Mianyang Habio Bioengineering Co Ltd
microchannel silicon nanowires cavity flow Microchannel Silicon Nanowires Cavity Flow, supplied by Mianyang Habio Bioengineering Co Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannel silicon nanowires cavity flow/product/Mianyang Habio Bioengineering Co Ltd Average 86 stars, based on 1 article reviews
microchannel silicon nanowires cavity flow - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
SMAC Corp
microfluidic chip serpentine microchannel with cavities (smac) Microfluidic Chip Serpentine Microchannel With Cavities (Smac), supplied by SMAC Corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microfluidic chip serpentine microchannel with cavities (smac)/product/SMAC Corp Average 90 stars, based on 1 article reviews
microfluidic chip serpentine microchannel with cavities (smac) - by Bioz Stars,
2026-05
90/100 stars
|
Buy from Supplier |
|
Cellvis Inc
pdms polydimethylsiloxane microchannel Pdms Polydimethylsiloxane Microchannel, supplied by Cellvis Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/pdms polydimethylsiloxane microchannel/product/Cellvis Inc Average 86 stars, based on 1 article reviews
pdms polydimethylsiloxane microchannel - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Matsunami Glass
microchannel Microchannel, supplied by Matsunami Glass, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannel/product/Matsunami Glass Average 86 stars, based on 1 article reviews
microchannel - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Nikon
microchannel ![]() Microchannel, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/microchannel/product/Nikon Average 99 stars, based on 1 article reviews
microchannel - by Bioz Stars,
2026-05
99/100 stars
|
Buy from Supplier |
Journal: PLOS One
Article Title: Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines
doi: 10.1371/journal.pone.0333491
Figure Lengend Snippet: (a) A schematic drawing of a microchannel chip for gene electrotransfer. Cells and plasmid vector suspension were introduced into single-lined microchannel via pipette tip and pneumatic pressure. An alternating biphasic wave, either sinusoidal or triangular, was applied across the electrodes, forming an electric field around them that facilitated plasmid vector transfer into cells. (b) Fabricated microchannel chip with inlet and outlet biopsy punches of 1- and 3-mm diameter, respectively. An unused branch channel for droplet formation was also visible . The scale bar is 200 µm. (c) Experimental setup for flow generation and voltage application. A pneumatic pump (Flow EZ 7000 mbar, Fluigent) was attached to the pipette tip at the inlet. The electric power source consisted of a waveform generator (33500B, Agilent) connected to a bipolar amplifier (BA4825, NF Co.). A 1 kΩ resistor was connected to the electrodes, and an oscilloscope (PicoScope 6404E, P2056, Pico Technology) monitored the electrode voltage. The voltage amplitude decreased as the solution contacts the electrodes, and amplitude fluctuations indicated cell passage, which helped to monitor channel activity.
Article Snippet: The flow within the
Techniques: Electrotransfer, Plasmid Preparation, Suspension, Transferring, Activity Assay
Journal: PLOS One
Article Title: Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines
doi: 10.1371/journal.pone.0333491
Figure Lengend Snippet: (a) Intensity of electric field in the microchannel without cells. (b) Intensity of electric field when a cell is centered in the channel between electrodes at 1 ms. (c) Transmembrane potential distribution on cell membrane at 1 ms based on asymptotic Smoluchowski equations. (d) Distribution of pore density on the plasma membrane. (e) Distribution of pore density on plasma membrane circumference at various application voltages at a time of 1 ms. (f) Pore density at q = 0, and 1 ms in various applications.
Article Snippet: The flow within the
Techniques: Membrane, Clinical Proteomics
Journal: PLOS One
Article Title: Gene electrotransfer with flow-through microchannel and lower alternating voltage generated induced pluripotent cells from human lymphoblastoid cell lines
doi: 10.1371/journal.pone.0333491
Figure Lengend Snippet: (a) Images of LCLs with bright field (BF), the fluorescence of Hoechst 33342 (blue), PI (red), and GFP expression (green). Bright-field images and fluorescent-filtered images with the filters of FITC, mCherry, and DAPI are taken, respectively. Positions of cells were slightly moved while taking with each fluorescent filter because LCLs are floating cells. Scale bar = 200 µm. (b) Microscopic images of microchannel around electrode pair. White arrows show the location of electrode elution. Bubbling and elution of electrodes are sometimes observed above 12.5 V application. Scale bar = 100 µm. (c) Transfection efficiency and viability of LCLs as a parameter of application voltages for sinusoidal wave and triangle wave. Significant differences between 0V application and other voltages are indicated by #. Significant differences between triangle and sinusoidal waves are depicted by *.
Article Snippet: The flow within the
Techniques: Fluorescence, Expressing, Transfection