|
Skyscan Corporation
high resolution micro computed tomography micro ct scanning ![]() High Resolution Micro Computed Tomography Micro Ct Scanning, supplied by Skyscan Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/computed+ct+high+micro+micro+resolution+scanning+tomography/pmc12859453-618-0-9 Average 86 stars, based on 1 article reviews
high resolution micro computed tomography micro ct scanning - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
MILabs
micro ct scans ![]() Micro Ct Scans, supplied by MILabs, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/Computed+Tomography/pm42213317-88-6-22 Average 97 stars, based on 1 article reviews
micro ct scans - by Bioz Stars,
2026-09
97/100 stars
|
Buy from Supplier |
|
Skyscan Corporation
micro computed tomography micro ct scans ![]() Micro Computed Tomography Micro Ct Scans, supplied by Skyscan Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/ct+micro+scanner/pm41888479-92-0-4 Average 86 stars, based on 1 article reviews
micro computed tomography micro ct scans - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
Bruker Corporation
micro computed tomography microct scanning ![]() Micro Computed Tomography Microct Scanning, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/SkyScan+1276/pmc12661998-182-8-4 Average 99 stars, based on 1 article reviews
micro computed tomography microct scanning - by Bioz Stars,
2026-09
99/100 stars
|
Buy from Supplier |
|
Revvity
micro computed tomography micro ct scanning ![]() Micro Computed Tomography Micro Ct Scanning, supplied by Revvity, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/Quantum+GX3+microCT/pmc12953778-41-13-19 Average 97 stars, based on 1 article reviews
micro computed tomography micro ct scanning - by Bioz Stars,
2026-09
97/100 stars
|
Buy from Supplier |
|
Revvity
micro computed tomography scanning ![]() Micro Computed Tomography Scanning, supplied by Revvity, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/Quantum+GX3+microCT/pmc12926504-85-19-29 Average 97 stars, based on 1 article reviews
micro computed tomography scanning - by Bioz Stars,
2026-09
97/100 stars
|
Buy from Supplier |
|
Skyscan Corporation
resolution micro computed tomography micro ct scanning ![]() Resolution Micro Computed Tomography Micro Ct Scanning, supplied by Skyscan Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/computed+ct+high+micro+micro+resolution+scanning+tomography/pm41596426-245-10-21 Average 86 stars, based on 1 article reviews
resolution micro computed tomography micro ct scanning - by Bioz Stars,
2026-09
86/100 stars
|
Buy from Supplier |
|
MILabs
micro computed tomography micro ct scanning ![]() Micro Computed Tomography Micro Ct Scanning, supplied by MILabs, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/micro-computer+tomography+scan/Computed+Tomography/10__1002_slash_adfm__202525790-410-0-4 Average 97 stars, based on 1 article reviews
micro computed tomography micro ct scanning - by Bioz Stars,
2026-09
97/100 stars
|
Buy from Supplier |
Journal: Bioactive Materials
Article Title: Sulfated polysaccharide prevents senescent adipocyte-driven osteonecrosis by stem cell fate reprogramming
doi: 10.1016/j.bioactmat.2025.11.039
Figure Lengend Snippet: Continuous intraosseous administration of SCS prevents glucocorticoid-induced bone degeneration. ( A ) Schematic illustration of the glucocorticoid (GC; MPS)-induced bone deterioration and intraosseous SCS treatment. ( B-D ) Representative H&E staining images of the femur at 6 weeks (B). Magnified views of the cortical bone and trabecular bone in the marrow cavity are shown on the right. Solid arrows indicate normal osteocytes, while hollow arrows indicate empty osteocyte lacunae. Quantification of empty lacunae ratios in cortical bone (C) and trabecular bone (D). n = 6 biological replicates. (Scale bars, 500 μm and 25 μm) ( E-H ) Representative immunofluorescence staining of OPN + mature osteoblasts, osteolectin + osteoprogenitors, and VE-cadherin + endothelial cells (ECs) in femur at 6 weeks (E), and corresponding quantifications (F–H). n = 6 biological replicates. (Scale bars, 100 μm and 20 μm) ( I and J ) Representative flow cytometry plots of capillary subtypes in the femur (I), with quantification of CD45 − Ter119 − CD31 hi Emcn hi ECs (J). n = 6 biological replicates. ( K and L ) Flow cytometry plots showing Sca-1 hi CD31 hi arteriolar ECs (K), and corresponding quantification (L). n = 6 biological replicates. ( M and N ) Representative micro-CT 3D images of the femur (M). Quantitative analysis of percent bone volume (BV/TV) (N). n = 6 biological replicates. (Scale bars, 1.5 mm, 600 μm and 545 μm) ( O and P ) ELISA analysis of VEGF (O) and PDGF-BB (P) levels in bone marrow supernatant and peripheral serum from PBS- and SCS-treated groups at week 6. n = 6 biological replicates. ( Q ) ELISA quantification of the osteogenic factor osteocalcin in peripheral serum at week 6. n = 6 biological replicates. Data are presented as mean ± SD. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001; ns, not significant. Statistical significance was determined using one-way ANOVA with Tukey's post hoc test ( C, D, F, G, H, J, L, N, O, P and Q ).
Article Snippet:
Techniques: Staining, Immunofluorescence, Flow Cytometry, Micro-CT, Enzyme-linked Immunosorbent Assay
Journal: Bioactive Materials
Article Title: Sulfated polysaccharide prevents senescent adipocyte-driven osteonecrosis by stem cell fate reprogramming
doi: 10.1016/j.bioactmat.2025.11.039
Figure Lengend Snippet: SCS targets downstream senescent lineage commitment of bone marrow MSCs to mitigate GC-induced bone deterioration. ( A ) Schematic diagram illustrating the experimental design: CD45 − Ter119 − CD31 − LepR + MSCs isolated from mice co-treated with SCS and MPS for 7 days were subjected to in vitro lineage-competitive differentiation, followed by DEX-induced senescence in lineage-mixed cells. These cells were then adoptively transplanted into healthy bone marrow cavity to assess bone deterioration development. ( B ) Representative H&E-stained images of the femur 12 weeks after adoptive transfer. PBS-DEX group: LepR + MSCs from PBS and MPS co-treated mice subjected to in vitro lineage differentiation and DEX-induced senescence, followed by transplantation. SCS-DEX group: LepR + MSCs from SCS and MPS co-treated mice processed similarly. PBS group: solvent control without cell transplantation. Solid arrows indicate intact osteocytes; hollow arrows indicate empty lacunae. (Scale bars, 250 μm and 25 μm) ( C – E ) Quantitative analysis of marrow hypertrophic adipocyte diameter (C), proportion of empty osteocyte lacunae in trabecular bone (D), and adipocyte number (E) in the metaphysis 12 weeks post-transplantation. n = 19 biological replicates (C), n = 6 biological replicates (D), n = 8 biological replicates (E). ( F ) Quantification of empty lacunae in epiphysis at 12 weeks post-transplantation. n = 6 biological replicates. ( G – I ) Representative flow cytometry plots of capillary ECs subtypes in the femur at 12 weeks (G), with quantification of CD45 − Ter119 − CD31 hi Emcn hi ECs (H) and CD45 − Ter119 − CD31 lo Emcn lo ECs (I). n = 6 biological replicates. ( J and K ) Representative flow cytometry plots (J) and corresponding quantification (K) of CD45 − Ter119 − Sca-1 hi CD31 hi arteriolar ECs in the femur at 12 weeks post-transplantation. n = 6 biological replicates. ( L ) Representative micro-CT images of the femur at 12 weeks post-transplantation across different treatment groups. (Scale bars, 1.5 mm and 500 μm) ( M – P ) Quantitative analysis of bone parameters in the metaphysis: bone mineral density (BMD) (M), percent bone volume (BV/TV) (N), trabecular separation (Tb.Sp) (O), and trabecular number (Tb.N) (P). n = 6 biological replicates. ( Q ) Serum ELISA analysis of the osteogenic marker osteocalcin at 12 weeks post-transplantation. n = 6 biological replicates. ( R and S ) ELISA analysis of PDGF-BB (R) and VEGF (S) in both bone marrow supernatant and peripheral serum at 12 weeks post-transplantation. n = 6 biological replicates. Data are presented as mean ± SD. ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, ∗∗∗∗ p < 0.0001; ns, not significant. Statistical significance was determined using one-way ANOVA with Tukey's post hoc test ( C, D, E, F, H, I, K, M, N, O, P, Q, R and S ).
Article Snippet:
Techniques: Isolation, In Vitro, Staining, Adoptive Transfer Assay, Transplantation Assay, Solvent, Control, Flow Cytometry, Micro-CT, Enzyme-linked Immunosorbent Assay, Marker
Journal: Bioactive Materials
Article Title: 3D printed scaffolds regulated by neural-bone metabolic coupling promote bone unit regeneration
doi: 10.1016/j.bioactmat.2025.10.031
Figure Lengend Snippet: In vivo experimental validation of GMN-GSE. (A) MicroCT maps of cranial defects in rat at 6 weeks and 12 weeks. (B–E) Quantitative analysis of BS, BV/TV, Tb.N, Tb.Sp at 6 weeks and 12 weeks.
Article Snippet: A SkyScan 1276 system (
Techniques: In Vivo, Biomarker Discovery
Journal: Cellular and Molecular Life Sciences: CMLS
Article Title: ANGPTL8 accelerates bone loss in diabetic mice by promoting osteoclastic differentiation and inhibiting osteoblastic differentiation through AMPK pathway-mediated metabolic reprogramming
doi: 10.1007/s00018-025-06077-x
Figure Lengend Snippet: The attenuation of diabetes-induced osteoporosis through ANGPTL8 knockout. ( A ) Schematic representation of the diabetic osteoporosis model construction. ( B ) FBG levels in mice at the onset (0 weeks) and conclusion (20 weeks) of the experiment. ( C ) Body weight measurements of mice at the onset (0 weeks) and conclusion (20 weeks) of the experiment. ( D ) ELISA analysis for quantifying ANGPTL8 levels in mouse plasma. ( E ) Micro-CT imaging of mouse femurs. ( F - J ) Analysis of Micro-CT data for bone mineral density (BMD), bone volume fraction (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp) in mouse femurs. Data are presented as mean ± SD; ( N = 5). ns: not significant, * p < 0.05, ** p < 0.01, *** p < 0.001
Article Snippet: The trabecular bone microarchitecture in the right femur of mice was assessed using
Techniques: Knock-Out, Enzyme-linked Immunosorbent Assay, Clinical Proteomics, Micro-CT, Imaging
Journal: Journal of Biomedical Optics
Article Title: Evaluation of analytical models to estimate depth of fluorescence objects in biological media
doi: 10.1117/1.JBO.31.2.026003
Figure Lengend Snippet: Experimental phantom composition. (a) Phantoms’ background absorption and reduced scattering coefficients. (b) Set of phantom molds with capillary tubes at different depths. (c) Capillary tube depth confirmation using micro-computed tomography.
Article Snippet: Once solidified, the phantoms immediately underwent fluorescence imaging followed by confirmation of fluorescent inclusion (i.e., capillary tube) depth by
Techniques: Micro-CT