Review




Structured Review

ActiGraph llc wearables fitbit one/zip
Wearables Fitbit One/Zip, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/actigraph+gt3x/pm37688071-392-24-27
Average 90 stars, based on 1 article reviews
wearables fitbit one/zip - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Blocking Assay:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Produced:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

T-Test:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Software:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Derivative Assay:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Activity Assay:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Comparison:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Biomarker Discovery:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Immunocytochemistry:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.

Control:

Article Title: Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment.
Article Snippet: Objectives: Inexpensive activity monitors have recently gained popularity with the general public.. Researchers have evaluated these consumer-based monitors in laboratory-conditions.. Given the current wide-spread consumer use of these devices, it is important to ensure users are attaining accurate information compared to previously validated measures.

Article Title: Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.
Article Snippet: Lee et al compared the accuracy of consumer monitors (Fitbit One (FO), Fitbit Zip (FZ), Jawbone UP24 (JU)) and one popular research-grade accelerometer, the ActiGraph (AG; ActiGraph, Pensacola, Florida, USA), with indirect calorimetry for estimating EE in a semistructured setting.

Article Title: The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: A systematic review.
Article Snippet: Daily step count for all consumer wearables correlated highly with validation criterion, especially the ActiGraph device: intraclass correlation coefficients (ICC) were 0.94 for Fitbit One, 0.94 for Zip, 0.86 for Charge HR and 0.96 for Misfit Shine.

Article Title: Wrist-Worn Activity Trackers in Laboratory and Free-Living Settings for Patients With Chronic Pain: Criterion Validity Study
Article Snippet: This corresponds to the findings of a study [ ] that compared step count estimation of healthy participants in a free-living setting using a Fitbit device (Fitbit One) and ActiGraph GT3X, and reported excellent agreement between the 2 measurements.

Article Title: Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review
Article Snippet: High N/NR 81 Gomersall et al. (2016, Australia) University staff (N=29; 39.6±11 yrs; 90% females; NR) 7 days Fitbit One (belt, bra, pocket; NR; NR; NR); Jawbone UP (wrist; NR; NR; NR) Intensity (Steps; Time spent in different intensities (MVPA, sedentary)) Wearable (ActiGraph GT3X+ (hip)) Pearson correlation; Spearman correlation; Bland-Altman analysis; Linear regression; Cohen’s kappa There was moderate-strong agreement between the ActiGraph and both Fitbit One and Jawbone UP for the estimation of daily steps.



Similar Products

90
Garmin Ltd fitbit one
Fitbit One, supplied by Garmin Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/fitbit+one/pm39001356-251-126-130
Average 90 stars, based on 1 article reviews
fitbit one - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Fitabase by Small Steps Labs fitbit one data
Fitbit One Data, supplied by Fitabase by Small Steps Labs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/fitbit+data/pm38857065-113-0-11
Average 90 stars, based on 1 article reviews
fitbit one data - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Fitabase by Small Steps Labs fitbit one accelerometer
Fitbit One Accelerometer, supplied by Fitabase by Small Steps Labs, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/fitbit+one+accelerometer/pm38857065-127-5-9
Average 90 stars, based on 1 article reviews
fitbit one accelerometer - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
ActiGraph llc wearables fitbit one/zip
Wearables Fitbit One/Zip, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/actigraph+gt3x/pm37688071-392-24-27
Average 90 stars, based on 1 article reviews
wearables fitbit one/zip - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
ActiGraph llc fitbit one/zip
Design, settings and aims of studies included in the systematic review.
Fitbit One/Zip, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/actigraph+gt3x/pmc10490754-199-24-27
Average 90 stars, based on 1 article reviews
fitbit one/zip - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
ActiGraph llc fitbit one
Design, settings and aims of studies included in the systematic review.
Fitbit One, supplied by ActiGraph llc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/fitbit+one/pmc09227659__mhealth_v10i6e36377_app1-132-64-61
Average 90 stars, based on 1 article reviews
fitbit one - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Thermo Fisher wearable sensor/device fitbit one
Design, settings and aims of studies included in the systematic review.
Wearable Sensor/Device Fitbit One, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fitbit+one/10__4236_slash_jbise__2022__157018-66-186-185
Average 90 stars, based on 1 article reviews
wearable sensor/device fitbit one - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Design, settings and aims of studies included in the systematic review.

Journal: Sensors (Basel, Switzerland)

Article Title: Physical Activity in Community-Dwelling Older Adults: Which Real-World Accelerometry Measures Are Robust? A Systematic Review

doi: 10.3390/s23177615

Figure Lengend Snippet: Design, settings and aims of studies included in the systematic review.

Article Snippet: Criterion validity between research-grade wearables and consumer-grade wearables was excellent for step counts measured at the right hip: ICC = 0.94 (95%CI [0.88, 0.97]) (FitBit One/Zip versus ActiGraph GT3X+) [ ] and the waist: ICC = 0.96 (95%CI [0.91, 0.99]) (Misfit Shine versus ActiGraph GT3X+) [ ] and ICC = 0.91 (95%CI [0.79, 0.97]) (NL2000i) [ ], but lower on the wrist: ICC ranged from ICC = 0.83 (95%CI [0.59, 0.93]) (Misfit Shine versus NL2000i) to ICC = 0.86 (95%CI [0.67, 0.94]) (Misfit Shine versus ActiGraph GT3X+) [ ].

Techniques: Activity Assay, Biomarker Discovery, Adhesive, Medications, Selection

Clinimetric properties and methods of studies included in the systematic review.

Journal: Sensors (Basel, Switzerland)

Article Title: Physical Activity in Community-Dwelling Older Adults: Which Real-World Accelerometry Measures Are Robust? A Systematic Review

doi: 10.3390/s23177615

Figure Lengend Snippet: Clinimetric properties and methods of studies included in the systematic review.

Article Snippet: Criterion validity between research-grade wearables and consumer-grade wearables was excellent for step counts measured at the right hip: ICC = 0.94 (95%CI [0.88, 0.97]) (FitBit One/Zip versus ActiGraph GT3X+) [ ] and the waist: ICC = 0.96 (95%CI [0.91, 0.99]) (Misfit Shine versus ActiGraph GT3X+) [ ] and ICC = 0.91 (95%CI [0.79, 0.97]) (NL2000i) [ ], but lower on the wrist: ICC ranged from ICC = 0.83 (95%CI [0.59, 0.93]) (Misfit Shine versus NL2000i) to ICC = 0.86 (95%CI [0.67, 0.94]) (Misfit Shine versus ActiGraph GT3X+) [ ].

Techniques: Activity Assay, Construct, Sequencing, Biomarker Discovery