Review





Similar Products

95
Agilent technologies allophycocyanin apc conjugated anti cd61 antibody40
Allophycocyanin Apc Conjugated Anti Cd61 Antibody40, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/allophycocyanin apc conjugated anti cd61 antibody40/product/Agilent technologies
Average 95 stars, based on 1 article reviews
allophycocyanin apc conjugated anti cd61 antibody40 - by Bioz Stars, 2026-03
95/100 stars
  Buy from Supplier

95
Miltenyi Biotec cd61 macs microbeads
Cd61 Macs Microbeads, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd61 macs microbeads/product/Miltenyi Biotec
Average 95 stars, based on 1 article reviews
cd61 macs microbeads - by Bioz Stars, 2026-03
95/100 stars
  Buy from Supplier

94
Miltenyi Biotec anti cd61 apc
Anti Cd61 Apc, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/anti cd61 apc/product/Miltenyi Biotec
Average 94 stars, based on 1 article reviews
anti cd61 apc - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

90
Miltenyi Biotec cd42b
Cd42b, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd42b/product/Miltenyi Biotec
Average 90 stars, based on 1 article reviews
cd42b - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

94
Miltenyi Biotec cd61
Cd61, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd61/product/Miltenyi Biotec
Average 94 stars, based on 1 article reviews
cd61 - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

92
Miltenyi Biotec cd61 integrin β3
Cd61 Integrin β3, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cd61 integrin β3/product/Miltenyi Biotec
Average 92 stars, based on 1 article reviews
cd61 integrin β3 - by Bioz Stars, 2026-03
92/100 stars
  Buy from Supplier

94
Proteintech antibody cd61
Comparison of three staining methods in different TOAST classification. We selected three representative thrombus slice samples and observed them under 100x and 400x magnification. By selecting a representative region and magnifying it 400 times. In HE staining, red represents RBC, blue represents WBC, and the rest are PLT + FIB complexes. In IHC staining, in <t>CD61,</t> brown indicates PLT, blue indicates WBC, and the rest are other complexes; in FGB, brown indicates FIB, blue indicates WBC, and the rest are other complexes; We found that fibrin was present in the areas rich in red blood cells. LAA, large-artery atherosclerosis; CE, cardiogenic embolism; SUE, stroke of undetermined etiology; CD61, cluster of differentiation 61; IHC, immunohistochemistry; RBC, red blood cell; PLT, platelet; FIB, fibrin; Original magnification: 100×, Scale bar = 200 μm; Total magnification: 400×, Scale bar = 50 μm.
Antibody Cd61, supplied by Proteintech, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/antibody cd61/product/Proteintech
Average 94 stars, based on 1 article reviews
antibody cd61 - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

94
Proteintech anti cd61 antibody
Breakdown of intestinal mucosal physical barrier and immune barrier in UC Rat models. (A) Representative immunofluorescence staining of α-SMA, Vinculin and <t>CD61</t> associated with tight junctions in colon tissue and (C, D, E) their relative fluorescence intensity. (B) Representative immunofluorescence staining of iNOS, CD206 and CD68 associated with macrophage typing in colon tissue and (F, G) their relative fluorescence intensity. Scale bar = 200 μm. Data represented as mean ± SD (error bars) (C, D, E, F, G) from biological replicates. ns: not significant, ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001.
Anti Cd61 Antibody, supplied by Proteintech, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/anti cd61 antibody/product/Proteintech
Average 94 stars, based on 1 article reviews
anti cd61 antibody - by Bioz Stars, 2026-03
94/100 stars
  Buy from Supplier

93
Bio-Rad chicken cd41 cd61
Breakdown of intestinal mucosal physical barrier and immune barrier in UC Rat models. (A) Representative immunofluorescence staining of α-SMA, Vinculin and <t>CD61</t> associated with tight junctions in colon tissue and (C, D, E) their relative fluorescence intensity. (B) Representative immunofluorescence staining of iNOS, CD206 and CD68 associated with macrophage typing in colon tissue and (F, G) their relative fluorescence intensity. Scale bar = 200 μm. Data represented as mean ± SD (error bars) (C, D, E, F, G) from biological replicates. ns: not significant, ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001.
Chicken Cd41 Cd61, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/chicken cd41 cd61/product/Bio-Rad
Average 93 stars, based on 1 article reviews
chicken cd41 cd61 - by Bioz Stars, 2026-03
93/100 stars
  Buy from Supplier

Image Search Results


Comparison of three staining methods in different TOAST classification. We selected three representative thrombus slice samples and observed them under 100x and 400x magnification. By selecting a representative region and magnifying it 400 times. In HE staining, red represents RBC, blue represents WBC, and the rest are PLT + FIB complexes. In IHC staining, in CD61, brown indicates PLT, blue indicates WBC, and the rest are other complexes; in FGB, brown indicates FIB, blue indicates WBC, and the rest are other complexes; We found that fibrin was present in the areas rich in red blood cells. LAA, large-artery atherosclerosis; CE, cardiogenic embolism; SUE, stroke of undetermined etiology; CD61, cluster of differentiation 61; IHC, immunohistochemistry; RBC, red blood cell; PLT, platelet; FIB, fibrin; Original magnification: 100×, Scale bar = 200 μm; Total magnification: 400×, Scale bar = 50 μm.

Journal: Frontiers in Neuroscience

Article Title: Histological analysis of thrombus composition in acute ischemic stroke with large vessel occlusion: impact of r-tPA treatment

doi: 10.3389/fnins.2025.1707934

Figure Lengend Snippet: Comparison of three staining methods in different TOAST classification. We selected three representative thrombus slice samples and observed them under 100x and 400x magnification. By selecting a representative region and magnifying it 400 times. In HE staining, red represents RBC, blue represents WBC, and the rest are PLT + FIB complexes. In IHC staining, in CD61, brown indicates PLT, blue indicates WBC, and the rest are other complexes; in FGB, brown indicates FIB, blue indicates WBC, and the rest are other complexes; We found that fibrin was present in the areas rich in red blood cells. LAA, large-artery atherosclerosis; CE, cardiogenic embolism; SUE, stroke of undetermined etiology; CD61, cluster of differentiation 61; IHC, immunohistochemistry; RBC, red blood cell; PLT, platelet; FIB, fibrin; Original magnification: 100×, Scale bar = 200 μm; Total magnification: 400×, Scale bar = 50 μm.

Article Snippet: The following steps were then carried out in sequence: (1) Antigen retrieval specific to the tissue (preventing excessive evaporation of the buffer solution and avoiding dry sections); (2) Blocking with 3% H2O2 (25 min, protected from light); (3) Blocking with serum (30 min, at room temperature); (4) Incubation with primary antibody CD61 (integrin β3, 66,952-1-ig, Proteintech, 1:1000) overnight at 4 °C; (5) Incubation with HRP-labeled secondary antibody (Anti-FGB Antibody, M01204-1, BOSTER, 1:200) for 50 min at room temperature; (6) Color development with DAB chromogen from the immunohistochemical kit followed by washing with water to stop the reaction; (7) Counterstaining with hematoxylin (3 min) and bluing with hematoxylin bluing solution; (8) Dehydration through a gradient of alcohol and clearing with xylene; (9) Mounting with neutral gum; (10) Analysis under an optical microscope.

Techniques: Comparison, Staining, Immunohistochemistry

Breakdown of intestinal mucosal physical barrier and immune barrier in UC Rat models. (A) Representative immunofluorescence staining of α-SMA, Vinculin and CD61 associated with tight junctions in colon tissue and (C, D, E) their relative fluorescence intensity. (B) Representative immunofluorescence staining of iNOS, CD206 and CD68 associated with macrophage typing in colon tissue and (F, G) their relative fluorescence intensity. Scale bar = 200 μm. Data represented as mean ± SD (error bars) (C, D, E, F, G) from biological replicates. ns: not significant, ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001.

Journal: Materials Today Bio

Article Title: Synergistic exacerbation of periprosthetic osteolysis by inflammatory bowel disease and titanium ions: Impaired osteogenesis of BMSCs via PI3K/AKT signaling

doi: 10.1016/j.mtbio.2025.102236

Figure Lengend Snippet: Breakdown of intestinal mucosal physical barrier and immune barrier in UC Rat models. (A) Representative immunofluorescence staining of α-SMA, Vinculin and CD61 associated with tight junctions in colon tissue and (C, D, E) their relative fluorescence intensity. (B) Representative immunofluorescence staining of iNOS, CD206 and CD68 associated with macrophage typing in colon tissue and (F, G) their relative fluorescence intensity. Scale bar = 200 μm. Data represented as mean ± SD (error bars) (C, D, E, F, G) from biological replicates. ns: not significant, ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001.

Article Snippet: Specifically, consecutive sections were permeated with 0.1 % TritonX-100 for 20 min. For tight junction protein, using anti-α-SMA antibody (1:200, 67735-1-Ig, Proteintech), anti-Vinculin antibody (1:200, 66305-1-Ig, Proteintech), and anti-CD61 antibody (1:200, 18309-1-AP, Proteintech); For osteogenic indicators, using anti-Runx2 antibody (1:200, 20700-1-AP, Proteintech), anti-Sp7 antibody (1:200, ab209484, Abcam), and OPN antibody (1:200, 22952-1-AP, Proteintech); For macrophage markers, using anti-iNOS antibody (1:200, 18985-1-AP, Proteintech), anti-CD206 antibody (1:200, 18704-1-AP, Proteintech), and anti-CD68 antibody (1:200, 28058-1-AP) to incubate with samples, followed by incubation with the fluorescently labeled secondary antibody and DAPI.

Techniques: Immunofluorescence, Staining, Fluorescence