Microelectrodes Inc leak free ag agcl reference electrode
Structure of a <t>conventional</t> <t>Ag/AgCl</t> reference electrode in a KCl saturated solution .
Leak Free Ag Agcl Reference Electrode, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/electrode+reference/pmc12899550-133-1-7
Average 86 stars, based on 1 article reviews
leak free ag agcl reference electrode - by Bioz Stars, 2026-11
86/100 stars

Images

1) Product Images from "On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications"

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

Journal: Sensors (Basel, Switzerland)

doi: 10.3390/s26030857

Structure of a conventional Ag/AgCl reference electrode in a KCl saturated solution .
Figure Legend Snippet: Structure of a conventional Ag/AgCl reference electrode in a KCl saturated solution .

Techniques Used:

( a ) Optical image of a wafer piece after electron beam lithography of the nanowires. The samples are arranged in 2 × 2 squares. Each sample consists of 48 nanowire FETs. Light areas are the nanowires and contact leads, while dark areas are the buried oxide. ( b ) Sample after bonding into a chip carrier. ( c ) SEM image of three nanowires (thin horizontal lines) with contact areas on the left (source) and a common bus line on the right (drain). ( d ) Cross-section of the fabricated device and a sketch of the measurement setup (not to scale). The liquid is delivered to the custom-made PDMS microchannels by a pump (indicated by arrows). A flow-through Ag/AgCl reference electrode is integrated in the Teflon (PTFE) tubing close to the microchannel. The working point of the nanowire transistor is adjusted by two voltages: a back-gate voltage Vbg (applied to the handle wafer) and a liquid-gate voltage Vref (applied to the reference electrode). Reprinted with permission from Reference . Copyright © 2012 American Chemical Society.
Figure Legend Snippet: ( a ) Optical image of a wafer piece after electron beam lithography of the nanowires. The samples are arranged in 2 × 2 squares. Each sample consists of 48 nanowire FETs. Light areas are the nanowires and contact leads, while dark areas are the buried oxide. ( b ) Sample after bonding into a chip carrier. ( c ) SEM image of three nanowires (thin horizontal lines) with contact areas on the left (source) and a common bus line on the right (drain). ( d ) Cross-section of the fabricated device and a sketch of the measurement setup (not to scale). The liquid is delivered to the custom-made PDMS microchannels by a pump (indicated by arrows). A flow-through Ag/AgCl reference electrode is integrated in the Teflon (PTFE) tubing close to the microchannel. The working point of the nanowire transistor is adjusted by two voltages: a back-gate voltage Vbg (applied to the handle wafer) and a liquid-gate voltage Vref (applied to the reference electrode). Reprinted with permission from Reference . Copyright © 2012 American Chemical Society.

Techniques Used:

( a ) Sensor concept with fluidic channel above nanowire region and realization of inlet and outlet flow. ( b ) Real fluid cell setup with contacted source and drain and PDMS channel for sample delivery as labeled, and position of the Ag/AgCl reference electrode. Microchips are of approximately 2 × 2 cm 2 . Reprinted from Ref. . Available under CC BY 4.0 license.
Figure Legend Snippet: ( a ) Sensor concept with fluidic channel above nanowire region and realization of inlet and outlet flow. ( b ) Real fluid cell setup with contacted source and drain and PDMS channel for sample delivery as labeled, and position of the Ag/AgCl reference electrode. Microchips are of approximately 2 × 2 cm 2 . Reprinted from Ref. . Available under CC BY 4.0 license.

Techniques Used: Labeling

A cross-sectional schematic image of a dual-gate (DG) ISFET. The designed active channel length and width are 10 µm and 10 µm, respectively. The thicknesses of the top active Si layer and of the BOx are 4.3 nm and 224 nm, respectively. A top SiO 2 layer with a thickness of 23 nm is grown by thermal oxidation for the sensing membrane. A commercial Ag/AgCl reference electrode is used for various pH buffer solutions. Reprinted from Ref. . Available under CC BY 4.0 license.
Figure Legend Snippet: A cross-sectional schematic image of a dual-gate (DG) ISFET. The designed active channel length and width are 10 µm and 10 µm, respectively. The thicknesses of the top active Si layer and of the BOx are 4.3 nm and 224 nm, respectively. A top SiO 2 layer with a thickness of 23 nm is grown by thermal oxidation for the sensing membrane. A commercial Ag/AgCl reference electrode is used for various pH buffer solutions. Reprinted from Ref. . Available under CC BY 4.0 license.

Techniques Used: Membrane

( a ) FESEM image of a Si NWFET with a microwell ( left ), and schematics for measuring the readout current for stabilization of the sample solution potential with a reference electrode ( right ). ( b ) Use of three reference electrodes for comparative study: ( i ) SCE-saturated calomel reference electrode, ( ii ) Ag/AgCl reference electrode in saturated KCl solution tube, and ( iii ) integrated reference electrode on chip with Ag/AgCl ink. The dimensions are a 5 nm thick top oxide and a 20 nm thick channel Si NW on a 145 nm thick BOx layer. The length channel is 2 µm. The chip size is about 5 × 7 mm. Reprinted from Ref. . Available under CC BY 4.0 license.
Figure Legend Snippet: ( a ) FESEM image of a Si NWFET with a microwell ( left ), and schematics for measuring the readout current for stabilization of the sample solution potential with a reference electrode ( right ). ( b ) Use of three reference electrodes for comparative study: ( i ) SCE-saturated calomel reference electrode, ( ii ) Ag/AgCl reference electrode in saturated KCl solution tube, and ( iii ) integrated reference electrode on chip with Ag/AgCl ink. The dimensions are a 5 nm thick top oxide and a 20 nm thick channel Si NW on a 145 nm thick BOx layer. The length channel is 2 µm. The chip size is about 5 × 7 mm. Reprinted from Ref. . Available under CC BY 4.0 license.

Techniques Used:

( left ) Cross-sectional schematic of Si NWFETs with standard commercial Ag/AgCl reference electrode, and SEM images ( right ) showing ultra-scaled opening access with diameter dimensions ranging from 250 nm down to 120 nm on top of the Si NW array. The latter is made up of 15 Si NWs, each with a 50 nm width. Reprinted from Ref. . Available under CC BY 4.0 license.
Figure Legend Snippet: ( left ) Cross-sectional schematic of Si NWFETs with standard commercial Ag/AgCl reference electrode, and SEM images ( right ) showing ultra-scaled opening access with diameter dimensions ranging from 250 nm down to 120 nm on top of the Si NW array. The latter is made up of 15 Si NWs, each with a 50 nm width. Reprinted from Ref. . Available under CC BY 4.0 license.

Techniques Used:

Schematic of a whole miniaturized micro-reference electrode (µF). A Ag/AgCl wire electrode is connected to a microfluidic KCl channel (3 cm × 500 µm × 80 µm) embedded in PDMS. Reproduced from Refs. [ , ] with permission from the Chemical and Biological Microsystems Society (CBMS). Copyright (2010) CBMS.
Figure Legend Snippet: Schematic of a whole miniaturized micro-reference electrode (µF). A Ag/AgCl wire electrode is connected to a microfluidic KCl channel (3 cm × 500 µm × 80 µm) embedded in PDMS. Reproduced from Refs. [ , ] with permission from the Chemical and Biological Microsystems Society (CBMS). Copyright (2010) CBMS.

Techniques Used:

Chip that integrates pseudo-Ag/AgCl REs, microfluidics, and sensing nanodevices: ( a ) optical image of the mounted microfluidics setup; ( b ) cartoon showing the cross-section of the Si Nanoribbon (NR)-ISFET coupled with the microfluidic module (not to scale). From bottom to top: (i) Si Nanoribbon (NR) chip; (ii) double-coated tape (the height of the channels is defined by the thickness of the tape, at 190 μm); (iii) PMMA cap as sealing polymer with the Ag/AgCl inlet and outlet tubes to avoid fluid leakages from the inlets/outlets . Reprinted with the permission of the authors.
Figure Legend Snippet: Chip that integrates pseudo-Ag/AgCl REs, microfluidics, and sensing nanodevices: ( a ) optical image of the mounted microfluidics setup; ( b ) cartoon showing the cross-section of the Si Nanoribbon (NR)-ISFET coupled with the microfluidic module (not to scale). From bottom to top: (i) Si Nanoribbon (NR) chip; (ii) double-coated tape (the height of the channels is defined by the thickness of the tape, at 190 μm); (iii) PMMA cap as sealing polymer with the Ag/AgCl inlet and outlet tubes to avoid fluid leakages from the inlets/outlets . Reprinted with the permission of the authors.

Techniques Used: Polymer

( a ) Schematic diagram of a multi-SiNW bioFETs with an integrated PDMS fluidic channel, Ag/AgCl wire as a solution gate, and Si substrate as a back-gate. ( b ) Image of an assembled multi-SiNW FET sensing platform. Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.
Figure Legend Snippet: ( a ) Schematic diagram of a multi-SiNW bioFETs with an integrated PDMS fluidic channel, Ag/AgCl wire as a solution gate, and Si substrate as a back-gate. ( b ) Image of an assembled multi-SiNW FET sensing platform. Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Techniques Used:

Planar pseudo-reference electrode integrated on the Si NW-based ISFET chip: ( a ) after the Ag/AgCl layer deposition; ( b ) after the 2 µm thick SU-8 layer passivation on the chip, except for the active sensing region and the contact pads, to prevent leakage current between the contacts and the solution. The BOx thickness is 200 nm. The Si NW has a thickness of 40 nm thick, width of 50 nm, and length of 10 µm. The gate oxide is 5 nm thick. The width, length, and height of the well holding the solution over the devices are 1200 µm, 1200 µm, and 2 µm, respectively. The width and length of the pseudo-Ag/AgCl reference electrode are 1000 µm and 1000 µm, respectively (thickness not described). Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.
Figure Legend Snippet: Planar pseudo-reference electrode integrated on the Si NW-based ISFET chip: ( a ) after the Ag/AgCl layer deposition; ( b ) after the 2 µm thick SU-8 layer passivation on the chip, except for the active sensing region and the contact pads, to prevent leakage current between the contacts and the solution. The BOx thickness is 200 nm. The Si NW has a thickness of 40 nm thick, width of 50 nm, and length of 10 µm. The gate oxide is 5 nm thick. The width, length, and height of the well holding the solution over the devices are 1200 µm, 1200 µm, and 2 µm, respectively. The width and length of the pseudo-Ag/AgCl reference electrode are 1000 µm and 1000 µm, respectively (thickness not described). Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Techniques Used:

Electrochemical sensor structure and characterization of a Ag/AgCl/Nafion reference electrode (RE). ( a ) Photo of a miniaturized, two-electrode setup, including a working electrode (WE) and an RE. ( b ) Schematic illustration of the cross-sectional view of the structural interface of the newly fabricated, all-solid-state Ag/AgCl/Nafion. ( c , d ) Cross-sectional SEM images that capture the layered structure of Ag/AgCl electrodes formed up to 10 cyclic voltammetry cycles ( c ) and the porous structure of primary AgCl nanoparticles ( d ). Reprinted with permission from Reference . Copyright © 2020 Elsevier.
Figure Legend Snippet: Electrochemical sensor structure and characterization of a Ag/AgCl/Nafion reference electrode (RE). ( a ) Photo of a miniaturized, two-electrode setup, including a working electrode (WE) and an RE. ( b ) Schematic illustration of the cross-sectional view of the structural interface of the newly fabricated, all-solid-state Ag/AgCl/Nafion. ( c , d ) Cross-sectional SEM images that capture the layered structure of Ag/AgCl electrodes formed up to 10 cyclic voltammetry cycles ( c ) and the porous structure of primary AgCl nanoparticles ( d ). Reprinted with permission from Reference . Copyright © 2020 Elsevier.

Techniques Used:

( a ) Schematic representation illustrating a planar Ag/AgCl pseudo-reference electrode obtained by 3D printing. Reprinted from Reference , available under CC BY-NC-ND license. ( b ) Photo of the first fabricated full-ink-jet-printed solid-state reference electrode on a 125 µm thick polymeric (polyethylene terephthalate–PET) film substrate. Reprinted with permission from Reference , Copyright © 2019 American Chemical Society. ( c ) Photo of a wearable flexible integrated sensing array (FISA) on a subject’s wrist, integrating the multiplexed sweat electrochemical sensor array and the wireless flexible printed circuit board (FPCB). Reproduced from with permission from the SNCSC.
Figure Legend Snippet: ( a ) Schematic representation illustrating a planar Ag/AgCl pseudo-reference electrode obtained by 3D printing. Reprinted from Reference , available under CC BY-NC-ND license. ( b ) Photo of the first fabricated full-ink-jet-printed solid-state reference electrode on a 125 µm thick polymeric (polyethylene terephthalate–PET) film substrate. Reprinted with permission from Reference , Copyright © 2019 American Chemical Society. ( c ) Photo of a wearable flexible integrated sensing array (FISA) on a subject’s wrist, integrating the multiplexed sweat electrochemical sensor array and the wireless flexible printed circuit board (FPCB). Reproduced from with permission from the SNCSC.

Techniques Used:

Normalized sensitivity value (ΔI/I0) according to the variation in pH concentration resulting from measurements of the real-time average value of Ids measured with two similar sensors and with three different reference electrodes: SCE-saturated calomel reference electrode, Ag/AgCl electrode (tube type), and integrated Ag/AgCl (ink) electrode. Reprinted from Ref. . Available under CC BY 4.0 license.
Figure Legend Snippet: Normalized sensitivity value (ΔI/I0) according to the variation in pH concentration resulting from measurements of the real-time average value of Ids measured with two similar sensors and with three different reference electrodes: SCE-saturated calomel reference electrode, Ag/AgCl electrode (tube type), and integrated Ag/AgCl (ink) electrode. Reprinted from Ref. . Available under CC BY 4.0 license.

Techniques Used: Concentration Assay

( a ) Schematic of protein sensing with a Si-nanograting FET (NGFET) and dual Ag/AgCl electrodes. The oxide–electrolyte surface of the nanograting is functionalized with antibody. The FET is biased in subthreshold region by a solution gate at the top of the fluidic channel. The other electrode monitors the bulk solution potential. ( b ) Optical image and ( c ) electron micrograph of a typical Si NGFET with 100 nanowires in the grating. Each nanowire is 50 nm in width, 30 nm in height, and 20 µm in length. ( d ) Three-dimensionally printed clamp for protein sensing with dual Ag/AgCl electrodes. ( e ) Species at the gate oxide surface after modification with TESU, antibody (mouse IgG), and passivation (with BSA). The corresponding antigen used in this study is anti-mouse IgG with gold. Reprinted with permission from Reference . Copyright © 2014 IEEE.
Figure Legend Snippet: ( a ) Schematic of protein sensing with a Si-nanograting FET (NGFET) and dual Ag/AgCl electrodes. The oxide–electrolyte surface of the nanograting is functionalized with antibody. The FET is biased in subthreshold region by a solution gate at the top of the fluidic channel. The other electrode monitors the bulk solution potential. ( b ) Optical image and ( c ) electron micrograph of a typical Si NGFET with 100 nanowires in the grating. Each nanowire is 50 nm in width, 30 nm in height, and 20 µm in length. ( d ) Three-dimensionally printed clamp for protein sensing with dual Ag/AgCl electrodes. ( e ) Species at the gate oxide surface after modification with TESU, antibody (mouse IgG), and passivation (with BSA). The corresponding antigen used in this study is anti-mouse IgG with gold. Reprinted with permission from Reference . Copyright © 2014 IEEE.

Techniques Used: Modification

Related Articles

other:

Article Title: Rapid microcystin-LR detection using antibody-based electrochemical biosensors with a simplified calibration curve approach
Article Snippet: The cleaning process of the MC-LR biosensor was characterized electrochemically using CV using the PalmSens 4 (PalmSens B.V., Houten, Netherlands) in a three-electrode system where the MC-LR biosensor served as the WE, a carbon counter electrode, and an external Ag/AgCl reference electrode (MI-401, Microelectrodes, Inc., Bedford, NH, USA).

Article Title: Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection
Article Snippet: Open circuit potential (OCP), and reverse current chronopotentiometry (RCP) measurements were measured with an Ag/AgCl reference electrode (MI-402, Microelectrodes Inc.) and a platinum Wire Counter Electrode (BASi MW-1032, Palmsens).

Article Title: Cost-effective screen-printed carbon electrode biosensors for rapid detection of microcystin-LR in surface waters for early warning of harmful algal blooms.
Article Snippet: Electrochemical characterization was conducted in a three-electrode system using a modified MC-LR/cysteamine/SPCE biosensor as the working electrode (WE), carbon counter electrode, and an Ag/AgCl reference electrode (MI-401, Microelectrodes, Inc., Bedford, NH, USA).

Cyclic Voltammetry:

Article Title: Design of Nanomaterial-Based Sensors for Enhanced Halogen Bonding.
Article Snippet: .. Cyclic voltammetry was performed by CH Instruments potentiostats (Models 650A, 630B, 610B and/or 420A) in glass electrochemical “sandwich” cells that feature an Ag/AgCl (saturated KCl) reference electrode (Microelectrodes, Inc.), a platinum wire (Sigma-Aldrich) counter electrode, and an evaporated gold substrate (EMF Corp., Ithaca, NY) as a working electrode defined by a Viton O-ring (0.32 cm2)�schematic representation provided in Supporting Information: Figure SI-1.54 Two types of cyclic voltammetry (CV) experiments, scanning from initial toward positive potentials in all cases, have been used in concert to measure XB interactions at film modified electrodes.55 Voltammetry was run for a minimum of three complete cycles to ensure reproducibility of behavior with last scans usually depicted in result comparisons. ..

Glass:

Article Title: Design of Nanomaterial-Based Sensors for Enhanced Halogen Bonding.
Article Snippet: .. Cyclic voltammetry was performed by CH Instruments potentiostats (Models 650A, 630B, 610B and/or 420A) in glass electrochemical “sandwich” cells that feature an Ag/AgCl (saturated KCl) reference electrode (Microelectrodes, Inc.), a platinum wire (Sigma-Aldrich) counter electrode, and an evaporated gold substrate (EMF Corp., Ithaca, NY) as a working electrode defined by a Viton O-ring (0.32 cm2)�schematic representation provided in Supporting Information: Figure SI-1.54 Two types of cyclic voltammetry (CV) experiments, scanning from initial toward positive potentials in all cases, have been used in concert to measure XB interactions at film modified electrodes.55 Voltammetry was run for a minimum of three complete cycles to ensure reproducibility of behavior with last scans usually depicted in result comparisons. ..

Platinum:

Article Title: Design of Nanomaterial-Based Sensors for Enhanced Halogen Bonding.
Article Snippet: .. Cyclic voltammetry was performed by CH Instruments potentiostats (Models 650A, 630B, 610B and/or 420A) in glass electrochemical “sandwich” cells that feature an Ag/AgCl (saturated KCl) reference electrode (Microelectrodes, Inc.), a platinum wire (Sigma-Aldrich) counter electrode, and an evaporated gold substrate (EMF Corp., Ithaca, NY) as a working electrode defined by a Viton O-ring (0.32 cm2)�schematic representation provided in Supporting Information: Figure SI-1.54 Two types of cyclic voltammetry (CV) experiments, scanning from initial toward positive potentials in all cases, have been used in concert to measure XB interactions at film modified electrodes.55 Voltammetry was run for a minimum of three complete cycles to ensure reproducibility of behavior with last scans usually depicted in result comparisons. ..

Modification:

Article Title: Design of Nanomaterial-Based Sensors for Enhanced Halogen Bonding.
Article Snippet: .. Cyclic voltammetry was performed by CH Instruments potentiostats (Models 650A, 630B, 610B and/or 420A) in glass electrochemical “sandwich” cells that feature an Ag/AgCl (saturated KCl) reference electrode (Microelectrodes, Inc.), a platinum wire (Sigma-Aldrich) counter electrode, and an evaporated gold substrate (EMF Corp., Ithaca, NY) as a working electrode defined by a Viton O-ring (0.32 cm2)�schematic representation provided in Supporting Information: Figure SI-1.54 Two types of cyclic voltammetry (CV) experiments, scanning from initial toward positive potentials in all cases, have been used in concert to measure XB interactions at film modified electrodes.55 Voltammetry was run for a minimum of three complete cycles to ensure reproducibility of behavior with last scans usually depicted in result comparisons. ..



Similar Products

86
Fisher Scientific double junction ag agcl reference electrode
Double Junction Ag Agcl Reference Electrode, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/ag+agcl+electrode+reference/us12656306-135-4-8
Average 86 stars, based on 1 article reviews
double junction ag agcl reference electrode - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

93
World Precision Instruments diameter ag agcl reference electrode
Diameter Ag Agcl Reference Electrode, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/Dri-Ref+Reference+Electrode/pm41925011-83-19-24
Average 93 stars, based on 1 article reviews
diameter ag agcl reference electrode - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
World Precision Instruments ag agcl reference electrode
Ag Agcl Reference Electrode, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/Dri-Ref+Reference+Electrode/10__1021_slash_acsomega__5c11272-124-1-5
Average 93 stars, based on 1 article reviews
ag agcl reference electrode - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

86
Warner Instruments ag agcl reference electrode re
Ag Agcl Reference Electrode Re, supplied by Warner Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/ag+agcl+pellet/us12578328-558-1-11
Average 86 stars, based on 1 article reviews
ag agcl reference electrode re - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

94
World Precision Instruments wired ag agcl reference electrode
Wired Ag Agcl Reference Electrode, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/Dri-Ref+Reference+Electrode/10__3390_slash_bios16020083-197-13-18
Average 94 stars, based on 1 article reviews
wired ag agcl reference electrode - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

86
Microelectrodes Inc leak free ag agcl reference electrode
Structure of a <t>conventional</t> <t>Ag/AgCl</t> reference electrode in a KCl saturated solution .
Leak Free Ag Agcl Reference Electrode, supplied by Microelectrodes Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/electrode+reference/pmc12899550-133-1-7
Average 86 stars, based on 1 article reviews
leak free ag agcl reference electrode - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

94
World Precision Instruments agcl reference electrode
Structure of a <t>conventional</t> <t>Ag/AgCl</t> reference electrode in a KCl saturated solution .
Agcl Reference Electrode, supplied by World Precision Instruments, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/agcl+reference+electrode/Micro+Dri-Ref+Reference+Electrode/pmc12899550-170-3-13
Average 94 stars, based on 1 article reviews
agcl reference electrode - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

Image Search Results


Structure of a conventional Ag/AgCl reference electrode in a KCl saturated solution .

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Structure of a conventional Ag/AgCl reference electrode in a KCl saturated solution .

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

( a ) Optical image of a wafer piece after electron beam lithography of the nanowires. The samples are arranged in 2 × 2 squares. Each sample consists of 48 nanowire FETs. Light areas are the nanowires and contact leads, while dark areas are the buried oxide. ( b ) Sample after bonding into a chip carrier. ( c ) SEM image of three nanowires (thin horizontal lines) with contact areas on the left (source) and a common bus line on the right (drain). ( d ) Cross-section of the fabricated device and a sketch of the measurement setup (not to scale). The liquid is delivered to the custom-made PDMS microchannels by a pump (indicated by arrows). A flow-through Ag/AgCl reference electrode is integrated in the Teflon (PTFE) tubing close to the microchannel. The working point of the nanowire transistor is adjusted by two voltages: a back-gate voltage Vbg (applied to the handle wafer) and a liquid-gate voltage Vref (applied to the reference electrode). Reprinted with permission from Reference . Copyright © 2012 American Chemical Society.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Optical image of a wafer piece after electron beam lithography of the nanowires. The samples are arranged in 2 × 2 squares. Each sample consists of 48 nanowire FETs. Light areas are the nanowires and contact leads, while dark areas are the buried oxide. ( b ) Sample after bonding into a chip carrier. ( c ) SEM image of three nanowires (thin horizontal lines) with contact areas on the left (source) and a common bus line on the right (drain). ( d ) Cross-section of the fabricated device and a sketch of the measurement setup (not to scale). The liquid is delivered to the custom-made PDMS microchannels by a pump (indicated by arrows). A flow-through Ag/AgCl reference electrode is integrated in the Teflon (PTFE) tubing close to the microchannel. The working point of the nanowire transistor is adjusted by two voltages: a back-gate voltage Vbg (applied to the handle wafer) and a liquid-gate voltage Vref (applied to the reference electrode). Reprinted with permission from Reference . Copyright © 2012 American Chemical Society.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

( a ) Sensor concept with fluidic channel above nanowire region and realization of inlet and outlet flow. ( b ) Real fluid cell setup with contacted source and drain and PDMS channel for sample delivery as labeled, and position of the Ag/AgCl reference electrode. Microchips are of approximately 2 × 2 cm 2 . Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Sensor concept with fluidic channel above nanowire region and realization of inlet and outlet flow. ( b ) Real fluid cell setup with contacted source and drain and PDMS channel for sample delivery as labeled, and position of the Ag/AgCl reference electrode. Microchips are of approximately 2 × 2 cm 2 . Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques: Labeling

A cross-sectional schematic image of a dual-gate (DG) ISFET. The designed active channel length and width are 10 µm and 10 µm, respectively. The thicknesses of the top active Si layer and of the BOx are 4.3 nm and 224 nm, respectively. A top SiO 2 layer with a thickness of 23 nm is grown by thermal oxidation for the sensing membrane. A commercial Ag/AgCl reference electrode is used for various pH buffer solutions. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: A cross-sectional schematic image of a dual-gate (DG) ISFET. The designed active channel length and width are 10 µm and 10 µm, respectively. The thicknesses of the top active Si layer and of the BOx are 4.3 nm and 224 nm, respectively. A top SiO 2 layer with a thickness of 23 nm is grown by thermal oxidation for the sensing membrane. A commercial Ag/AgCl reference electrode is used for various pH buffer solutions. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques: Membrane

( a ) FESEM image of a Si NWFET with a microwell ( left ), and schematics for measuring the readout current for stabilization of the sample solution potential with a reference electrode ( right ). ( b ) Use of three reference electrodes for comparative study: ( i ) SCE-saturated calomel reference electrode, ( ii ) Ag/AgCl reference electrode in saturated KCl solution tube, and ( iii ) integrated reference electrode on chip with Ag/AgCl ink. The dimensions are a 5 nm thick top oxide and a 20 nm thick channel Si NW on a 145 nm thick BOx layer. The length channel is 2 µm. The chip size is about 5 × 7 mm. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) FESEM image of a Si NWFET with a microwell ( left ), and schematics for measuring the readout current for stabilization of the sample solution potential with a reference electrode ( right ). ( b ) Use of three reference electrodes for comparative study: ( i ) SCE-saturated calomel reference electrode, ( ii ) Ag/AgCl reference electrode in saturated KCl solution tube, and ( iii ) integrated reference electrode on chip with Ag/AgCl ink. The dimensions are a 5 nm thick top oxide and a 20 nm thick channel Si NW on a 145 nm thick BOx layer. The length channel is 2 µm. The chip size is about 5 × 7 mm. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

( left ) Cross-sectional schematic of Si NWFETs with standard commercial Ag/AgCl reference electrode, and SEM images ( right ) showing ultra-scaled opening access with diameter dimensions ranging from 250 nm down to 120 nm on top of the Si NW array. The latter is made up of 15 Si NWs, each with a 50 nm width. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( left ) Cross-sectional schematic of Si NWFETs with standard commercial Ag/AgCl reference electrode, and SEM images ( right ) showing ultra-scaled opening access with diameter dimensions ranging from 250 nm down to 120 nm on top of the Si NW array. The latter is made up of 15 Si NWs, each with a 50 nm width. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

Schematic of a whole miniaturized micro-reference electrode (µF). A Ag/AgCl wire electrode is connected to a microfluidic KCl channel (3 cm × 500 µm × 80 µm) embedded in PDMS. Reproduced from Refs. [ , ] with permission from the Chemical and Biological Microsystems Society (CBMS). Copyright (2010) CBMS.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Schematic of a whole miniaturized micro-reference electrode (µF). A Ag/AgCl wire electrode is connected to a microfluidic KCl channel (3 cm × 500 µm × 80 µm) embedded in PDMS. Reproduced from Refs. [ , ] with permission from the Chemical and Biological Microsystems Society (CBMS). Copyright (2010) CBMS.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

Chip that integrates pseudo-Ag/AgCl REs, microfluidics, and sensing nanodevices: ( a ) optical image of the mounted microfluidics setup; ( b ) cartoon showing the cross-section of the Si Nanoribbon (NR)-ISFET coupled with the microfluidic module (not to scale). From bottom to top: (i) Si Nanoribbon (NR) chip; (ii) double-coated tape (the height of the channels is defined by the thickness of the tape, at 190 μm); (iii) PMMA cap as sealing polymer with the Ag/AgCl inlet and outlet tubes to avoid fluid leakages from the inlets/outlets . Reprinted with the permission of the authors.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Chip that integrates pseudo-Ag/AgCl REs, microfluidics, and sensing nanodevices: ( a ) optical image of the mounted microfluidics setup; ( b ) cartoon showing the cross-section of the Si Nanoribbon (NR)-ISFET coupled with the microfluidic module (not to scale). From bottom to top: (i) Si Nanoribbon (NR) chip; (ii) double-coated tape (the height of the channels is defined by the thickness of the tape, at 190 μm); (iii) PMMA cap as sealing polymer with the Ag/AgCl inlet and outlet tubes to avoid fluid leakages from the inlets/outlets . Reprinted with the permission of the authors.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques: Polymer

( a ) Schematic diagram of a multi-SiNW bioFETs with an integrated PDMS fluidic channel, Ag/AgCl wire as a solution gate, and Si substrate as a back-gate. ( b ) Image of an assembled multi-SiNW FET sensing platform. Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Schematic diagram of a multi-SiNW bioFETs with an integrated PDMS fluidic channel, Ag/AgCl wire as a solution gate, and Si substrate as a back-gate. ( b ) Image of an assembled multi-SiNW FET sensing platform. Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

Planar pseudo-reference electrode integrated on the Si NW-based ISFET chip: ( a ) after the Ag/AgCl layer deposition; ( b ) after the 2 µm thick SU-8 layer passivation on the chip, except for the active sensing region and the contact pads, to prevent leakage current between the contacts and the solution. The BOx thickness is 200 nm. The Si NW has a thickness of 40 nm thick, width of 50 nm, and length of 10 µm. The gate oxide is 5 nm thick. The width, length, and height of the well holding the solution over the devices are 1200 µm, 1200 µm, and 2 µm, respectively. The width and length of the pseudo-Ag/AgCl reference electrode are 1000 µm and 1000 µm, respectively (thickness not described). Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Planar pseudo-reference electrode integrated on the Si NW-based ISFET chip: ( a ) after the Ag/AgCl layer deposition; ( b ) after the 2 µm thick SU-8 layer passivation on the chip, except for the active sensing region and the contact pads, to prevent leakage current between the contacts and the solution. The BOx thickness is 200 nm. The Si NW has a thickness of 40 nm thick, width of 50 nm, and length of 10 µm. The gate oxide is 5 nm thick. The width, length, and height of the well holding the solution over the devices are 1200 µm, 1200 µm, and 2 µm, respectively. The width and length of the pseudo-Ag/AgCl reference electrode are 1000 µm and 1000 µm, respectively (thickness not described). Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

Electrochemical sensor structure and characterization of a Ag/AgCl/Nafion reference electrode (RE). ( a ) Photo of a miniaturized, two-electrode setup, including a working electrode (WE) and an RE. ( b ) Schematic illustration of the cross-sectional view of the structural interface of the newly fabricated, all-solid-state Ag/AgCl/Nafion. ( c , d ) Cross-sectional SEM images that capture the layered structure of Ag/AgCl electrodes formed up to 10 cyclic voltammetry cycles ( c ) and the porous structure of primary AgCl nanoparticles ( d ). Reprinted with permission from Reference . Copyright © 2020 Elsevier.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Electrochemical sensor structure and characterization of a Ag/AgCl/Nafion reference electrode (RE). ( a ) Photo of a miniaturized, two-electrode setup, including a working electrode (WE) and an RE. ( b ) Schematic illustration of the cross-sectional view of the structural interface of the newly fabricated, all-solid-state Ag/AgCl/Nafion. ( c , d ) Cross-sectional SEM images that capture the layered structure of Ag/AgCl electrodes formed up to 10 cyclic voltammetry cycles ( c ) and the porous structure of primary AgCl nanoparticles ( d ). Reprinted with permission from Reference . Copyright © 2020 Elsevier.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

( a ) Schematic representation illustrating a planar Ag/AgCl pseudo-reference electrode obtained by 3D printing. Reprinted from Reference , available under CC BY-NC-ND license. ( b ) Photo of the first fabricated full-ink-jet-printed solid-state reference electrode on a 125 µm thick polymeric (polyethylene terephthalate–PET) film substrate. Reprinted with permission from Reference , Copyright © 2019 American Chemical Society. ( c ) Photo of a wearable flexible integrated sensing array (FISA) on a subject’s wrist, integrating the multiplexed sweat electrochemical sensor array and the wireless flexible printed circuit board (FPCB). Reproduced from with permission from the SNCSC.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Schematic representation illustrating a planar Ag/AgCl pseudo-reference electrode obtained by 3D printing. Reprinted from Reference , available under CC BY-NC-ND license. ( b ) Photo of the first fabricated full-ink-jet-printed solid-state reference electrode on a 125 µm thick polymeric (polyethylene terephthalate–PET) film substrate. Reprinted with permission from Reference , Copyright © 2019 American Chemical Society. ( c ) Photo of a wearable flexible integrated sensing array (FISA) on a subject’s wrist, integrating the multiplexed sweat electrochemical sensor array and the wireless flexible printed circuit board (FPCB). Reproduced from with permission from the SNCSC.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques:

Normalized sensitivity value (ΔI/I0) according to the variation in pH concentration resulting from measurements of the real-time average value of Ids measured with two similar sensors and with three different reference electrodes: SCE-saturated calomel reference electrode, Ag/AgCl electrode (tube type), and integrated Ag/AgCl (ink) electrode. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Normalized sensitivity value (ΔI/I0) according to the variation in pH concentration resulting from measurements of the real-time average value of Ids measured with two similar sensors and with three different reference electrodes: SCE-saturated calomel reference electrode, Ag/AgCl electrode (tube type), and integrated Ag/AgCl (ink) electrode. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques: Concentration Assay

( a ) Schematic of protein sensing with a Si-nanograting FET (NGFET) and dual Ag/AgCl electrodes. The oxide–electrolyte surface of the nanograting is functionalized with antibody. The FET is biased in subthreshold region by a solution gate at the top of the fluidic channel. The other electrode monitors the bulk solution potential. ( b ) Optical image and ( c ) electron micrograph of a typical Si NGFET with 100 nanowires in the grating. Each nanowire is 50 nm in width, 30 nm in height, and 20 µm in length. ( d ) Three-dimensionally printed clamp for protein sensing with dual Ag/AgCl electrodes. ( e ) Species at the gate oxide surface after modification with TESU, antibody (mouse IgG), and passivation (with BSA). The corresponding antigen used in this study is anti-mouse IgG with gold. Reprinted with permission from Reference . Copyright © 2014 IEEE.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Schematic of protein sensing with a Si-nanograting FET (NGFET) and dual Ag/AgCl electrodes. The oxide–electrolyte surface of the nanograting is functionalized with antibody. The FET is biased in subthreshold region by a solution gate at the top of the fluidic channel. The other electrode monitors the bulk solution potential. ( b ) Optical image and ( c ) electron micrograph of a typical Si NGFET with 100 nanowires in the grating. Each nanowire is 50 nm in width, 30 nm in height, and 20 µm in length. ( d ) Three-dimensionally printed clamp for protein sensing with dual Ag/AgCl electrodes. ( e ) Species at the gate oxide surface after modification with TESU, antibody (mouse IgG), and passivation (with BSA). The corresponding antigen used in this study is anti-mouse IgG with gold. Reprinted with permission from Reference . Copyright © 2014 IEEE.

Article Snippet: A leak-free Ag/AgCl reference electrode (purchased at Microelectrodes Inc., Bedford, NH, USA) installed at the inlet tube assures measurement against a stable liquid potential ( a,b) [ ].

Techniques: Modification

Structure of a conventional Ag/AgCl reference electrode in a KCl saturated solution .

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Structure of a conventional Ag/AgCl reference electrode in a KCl saturated solution .

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

( a ) Optical image of a wafer piece after electron beam lithography of the nanowires. The samples are arranged in 2 × 2 squares. Each sample consists of 48 nanowire FETs. Light areas are the nanowires and contact leads, while dark areas are the buried oxide. ( b ) Sample after bonding into a chip carrier. ( c ) SEM image of three nanowires (thin horizontal lines) with contact areas on the left (source) and a common bus line on the right (drain). ( d ) Cross-section of the fabricated device and a sketch of the measurement setup (not to scale). The liquid is delivered to the custom-made PDMS microchannels by a pump (indicated by arrows). A flow-through Ag/AgCl reference electrode is integrated in the Teflon (PTFE) tubing close to the microchannel. The working point of the nanowire transistor is adjusted by two voltages: a back-gate voltage Vbg (applied to the handle wafer) and a liquid-gate voltage Vref (applied to the reference electrode). Reprinted with permission from Reference . Copyright © 2012 American Chemical Society.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Optical image of a wafer piece after electron beam lithography of the nanowires. The samples are arranged in 2 × 2 squares. Each sample consists of 48 nanowire FETs. Light areas are the nanowires and contact leads, while dark areas are the buried oxide. ( b ) Sample after bonding into a chip carrier. ( c ) SEM image of three nanowires (thin horizontal lines) with contact areas on the left (source) and a common bus line on the right (drain). ( d ) Cross-section of the fabricated device and a sketch of the measurement setup (not to scale). The liquid is delivered to the custom-made PDMS microchannels by a pump (indicated by arrows). A flow-through Ag/AgCl reference electrode is integrated in the Teflon (PTFE) tubing close to the microchannel. The working point of the nanowire transistor is adjusted by two voltages: a back-gate voltage Vbg (applied to the handle wafer) and a liquid-gate voltage Vref (applied to the reference electrode). Reprinted with permission from Reference . Copyright © 2012 American Chemical Society.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

( a ) Sensor concept with fluidic channel above nanowire region and realization of inlet and outlet flow. ( b ) Real fluid cell setup with contacted source and drain and PDMS channel for sample delivery as labeled, and position of the Ag/AgCl reference electrode. Microchips are of approximately 2 × 2 cm 2 . Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Sensor concept with fluidic channel above nanowire region and realization of inlet and outlet flow. ( b ) Real fluid cell setup with contacted source and drain and PDMS channel for sample delivery as labeled, and position of the Ag/AgCl reference electrode. Microchips are of approximately 2 × 2 cm 2 . Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques: Labeling

A cross-sectional schematic image of a dual-gate (DG) ISFET. The designed active channel length and width are 10 µm and 10 µm, respectively. The thicknesses of the top active Si layer and of the BOx are 4.3 nm and 224 nm, respectively. A top SiO 2 layer with a thickness of 23 nm is grown by thermal oxidation for the sensing membrane. A commercial Ag/AgCl reference electrode is used for various pH buffer solutions. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: A cross-sectional schematic image of a dual-gate (DG) ISFET. The designed active channel length and width are 10 µm and 10 µm, respectively. The thicknesses of the top active Si layer and of the BOx are 4.3 nm and 224 nm, respectively. A top SiO 2 layer with a thickness of 23 nm is grown by thermal oxidation for the sensing membrane. A commercial Ag/AgCl reference electrode is used for various pH buffer solutions. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques: Membrane

( a ) FESEM image of a Si NWFET with a microwell ( left ), and schematics for measuring the readout current for stabilization of the sample solution potential with a reference electrode ( right ). ( b ) Use of three reference electrodes for comparative study: ( i ) SCE-saturated calomel reference electrode, ( ii ) Ag/AgCl reference electrode in saturated KCl solution tube, and ( iii ) integrated reference electrode on chip with Ag/AgCl ink. The dimensions are a 5 nm thick top oxide and a 20 nm thick channel Si NW on a 145 nm thick BOx layer. The length channel is 2 µm. The chip size is about 5 × 7 mm. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) FESEM image of a Si NWFET with a microwell ( left ), and schematics for measuring the readout current for stabilization of the sample solution potential with a reference electrode ( right ). ( b ) Use of three reference electrodes for comparative study: ( i ) SCE-saturated calomel reference electrode, ( ii ) Ag/AgCl reference electrode in saturated KCl solution tube, and ( iii ) integrated reference electrode on chip with Ag/AgCl ink. The dimensions are a 5 nm thick top oxide and a 20 nm thick channel Si NW on a 145 nm thick BOx layer. The length channel is 2 µm. The chip size is about 5 × 7 mm. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

( left ) Cross-sectional schematic of Si NWFETs with standard commercial Ag/AgCl reference electrode, and SEM images ( right ) showing ultra-scaled opening access with diameter dimensions ranging from 250 nm down to 120 nm on top of the Si NW array. The latter is made up of 15 Si NWs, each with a 50 nm width. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( left ) Cross-sectional schematic of Si NWFETs with standard commercial Ag/AgCl reference electrode, and SEM images ( right ) showing ultra-scaled opening access with diameter dimensions ranging from 250 nm down to 120 nm on top of the Si NW array. The latter is made up of 15 Si NWs, each with a 50 nm width. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

Schematic of a whole miniaturized micro-reference electrode (µF). A Ag/AgCl wire electrode is connected to a microfluidic KCl channel (3 cm × 500 µm × 80 µm) embedded in PDMS. Reproduced from Refs. [ , ] with permission from the Chemical and Biological Microsystems Society (CBMS). Copyright (2010) CBMS.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Schematic of a whole miniaturized micro-reference electrode (µF). A Ag/AgCl wire electrode is connected to a microfluidic KCl channel (3 cm × 500 µm × 80 µm) embedded in PDMS. Reproduced from Refs. [ , ] with permission from the Chemical and Biological Microsystems Society (CBMS). Copyright (2010) CBMS.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

Chip that integrates pseudo-Ag/AgCl REs, microfluidics, and sensing nanodevices: ( a ) optical image of the mounted microfluidics setup; ( b ) cartoon showing the cross-section of the Si Nanoribbon (NR)-ISFET coupled with the microfluidic module (not to scale). From bottom to top: (i) Si Nanoribbon (NR) chip; (ii) double-coated tape (the height of the channels is defined by the thickness of the tape, at 190 μm); (iii) PMMA cap as sealing polymer with the Ag/AgCl inlet and outlet tubes to avoid fluid leakages from the inlets/outlets . Reprinted with the permission of the authors.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Chip that integrates pseudo-Ag/AgCl REs, microfluidics, and sensing nanodevices: ( a ) optical image of the mounted microfluidics setup; ( b ) cartoon showing the cross-section of the Si Nanoribbon (NR)-ISFET coupled with the microfluidic module (not to scale). From bottom to top: (i) Si Nanoribbon (NR) chip; (ii) double-coated tape (the height of the channels is defined by the thickness of the tape, at 190 μm); (iii) PMMA cap as sealing polymer with the Ag/AgCl inlet and outlet tubes to avoid fluid leakages from the inlets/outlets . Reprinted with the permission of the authors.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques: Polymer

( a ) Schematic diagram of a multi-SiNW bioFETs with an integrated PDMS fluidic channel, Ag/AgCl wire as a solution gate, and Si substrate as a back-gate. ( b ) Image of an assembled multi-SiNW FET sensing platform. Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Schematic diagram of a multi-SiNW bioFETs with an integrated PDMS fluidic channel, Ag/AgCl wire as a solution gate, and Si substrate as a back-gate. ( b ) Image of an assembled multi-SiNW FET sensing platform. Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

Planar pseudo-reference electrode integrated on the Si NW-based ISFET chip: ( a ) after the Ag/AgCl layer deposition; ( b ) after the 2 µm thick SU-8 layer passivation on the chip, except for the active sensing region and the contact pads, to prevent leakage current between the contacts and the solution. The BOx thickness is 200 nm. The Si NW has a thickness of 40 nm thick, width of 50 nm, and length of 10 µm. The gate oxide is 5 nm thick. The width, length, and height of the well holding the solution over the devices are 1200 µm, 1200 µm, and 2 µm, respectively. The width and length of the pseudo-Ag/AgCl reference electrode are 1000 µm and 1000 µm, respectively (thickness not described). Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Planar pseudo-reference electrode integrated on the Si NW-based ISFET chip: ( a ) after the Ag/AgCl layer deposition; ( b ) after the 2 µm thick SU-8 layer passivation on the chip, except for the active sensing region and the contact pads, to prevent leakage current between the contacts and the solution. The BOx thickness is 200 nm. The Si NW has a thickness of 40 nm thick, width of 50 nm, and length of 10 µm. The gate oxide is 5 nm thick. The width, length, and height of the well holding the solution over the devices are 1200 µm, 1200 µm, and 2 µm, respectively. The width and length of the pseudo-Ag/AgCl reference electrode are 1000 µm and 1000 µm, respectively (thickness not described). Reprinted with permission from Reference . Copyright © 2011 Royal Society of Chemistry.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

Electrochemical sensor structure and characterization of a Ag/AgCl/Nafion reference electrode (RE). ( a ) Photo of a miniaturized, two-electrode setup, including a working electrode (WE) and an RE. ( b ) Schematic illustration of the cross-sectional view of the structural interface of the newly fabricated, all-solid-state Ag/AgCl/Nafion. ( c , d ) Cross-sectional SEM images that capture the layered structure of Ag/AgCl electrodes formed up to 10 cyclic voltammetry cycles ( c ) and the porous structure of primary AgCl nanoparticles ( d ). Reprinted with permission from Reference . Copyright © 2020 Elsevier.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Electrochemical sensor structure and characterization of a Ag/AgCl/Nafion reference electrode (RE). ( a ) Photo of a miniaturized, two-electrode setup, including a working electrode (WE) and an RE. ( b ) Schematic illustration of the cross-sectional view of the structural interface of the newly fabricated, all-solid-state Ag/AgCl/Nafion. ( c , d ) Cross-sectional SEM images that capture the layered structure of Ag/AgCl electrodes formed up to 10 cyclic voltammetry cycles ( c ) and the porous structure of primary AgCl nanoparticles ( d ). Reprinted with permission from Reference . Copyright © 2020 Elsevier.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

( a ) Schematic representation illustrating a planar Ag/AgCl pseudo-reference electrode obtained by 3D printing. Reprinted from Reference , available under CC BY-NC-ND license. ( b ) Photo of the first fabricated full-ink-jet-printed solid-state reference electrode on a 125 µm thick polymeric (polyethylene terephthalate–PET) film substrate. Reprinted with permission from Reference , Copyright © 2019 American Chemical Society. ( c ) Photo of a wearable flexible integrated sensing array (FISA) on a subject’s wrist, integrating the multiplexed sweat electrochemical sensor array and the wireless flexible printed circuit board (FPCB). Reproduced from with permission from the SNCSC.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Schematic representation illustrating a planar Ag/AgCl pseudo-reference electrode obtained by 3D printing. Reprinted from Reference , available under CC BY-NC-ND license. ( b ) Photo of the first fabricated full-ink-jet-printed solid-state reference electrode on a 125 µm thick polymeric (polyethylene terephthalate–PET) film substrate. Reprinted with permission from Reference , Copyright © 2019 American Chemical Society. ( c ) Photo of a wearable flexible integrated sensing array (FISA) on a subject’s wrist, integrating the multiplexed sweat electrochemical sensor array and the wireless flexible printed circuit board (FPCB). Reproduced from with permission from the SNCSC.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques:

Normalized sensitivity value (ΔI/I0) according to the variation in pH concentration resulting from measurements of the real-time average value of Ids measured with two similar sensors and with three different reference electrodes: SCE-saturated calomel reference electrode, Ag/AgCl electrode (tube type), and integrated Ag/AgCl (ink) electrode. Reprinted from Ref. . Available under CC BY 4.0 license.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: Normalized sensitivity value (ΔI/I0) according to the variation in pH concentration resulting from measurements of the real-time average value of Ids measured with two similar sensors and with three different reference electrodes: SCE-saturated calomel reference electrode, Ag/AgCl electrode (tube type), and integrated Ag/AgCl (ink) electrode. Reprinted from Ref. . Available under CC BY 4.0 license.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques: Concentration Assay

( a ) Schematic of protein sensing with a Si-nanograting FET (NGFET) and dual Ag/AgCl electrodes. The oxide–electrolyte surface of the nanograting is functionalized with antibody. The FET is biased in subthreshold region by a solution gate at the top of the fluidic channel. The other electrode monitors the bulk solution potential. ( b ) Optical image and ( c ) electron micrograph of a typical Si NGFET with 100 nanowires in the grating. Each nanowire is 50 nm in width, 30 nm in height, and 20 µm in length. ( d ) Three-dimensionally printed clamp for protein sensing with dual Ag/AgCl electrodes. ( e ) Species at the gate oxide surface after modification with TESU, antibody (mouse IgG), and passivation (with BSA). The corresponding antigen used in this study is anti-mouse IgG with gold. Reprinted with permission from Reference . Copyright © 2014 IEEE.

Journal: Sensors (Basel, Switzerland)

Article Title: On the Use of Ag/AgCl Reference Electrode in Silicon Nanowire Field Effect Transistors for pH and Biosensing Applications

doi: 10.3390/s26030857

Figure Lengend Snippet: ( a ) Schematic of protein sensing with a Si-nanograting FET (NGFET) and dual Ag/AgCl electrodes. The oxide–electrolyte surface of the nanograting is functionalized with antibody. The FET is biased in subthreshold region by a solution gate at the top of the fluidic channel. The other electrode monitors the bulk solution potential. ( b ) Optical image and ( c ) electron micrograph of a typical Si NGFET with 100 nanowires in the grating. Each nanowire is 50 nm in width, 30 nm in height, and 20 µm in length. ( d ) Three-dimensionally printed clamp for protein sensing with dual Ag/AgCl electrodes. ( e ) Species at the gate oxide surface after modification with TESU, antibody (mouse IgG), and passivation (with BSA). The corresponding antigen used in this study is anti-mouse IgG with gold. Reprinted with permission from Reference . Copyright © 2014 IEEE.

Article Snippet: A standard commercial Ag/AgCl reference electrode was used (Micro-Dri-Ref, 450 μm diameter from World Precision Instruments).

Techniques: Modification