VICI AG
af4 device Af4 Device, supplied by VICI AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/af4 device/product/VICI AG Average 90 stars, based on 1 article reviews
af4 device - by Bioz Stars,
2026-05
90/100 stars
|
Buy from Supplier |
|
Postnova Analytics
af4 device Af4 Device, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/af4 device/product/Postnova Analytics Average 90 stars, based on 1 article reviews
af4 device - by Bioz Stars,
2026-05
90/100 stars
|
Buy from Supplier |
|
Waters Corporation
af4 device ![]() Af4 Device, supplied by Waters Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/af4 device/product/Waters Corporation Average 86 stars, based on 1 article reviews
af4 device - by Bioz Stars,
2026-05
86/100 stars
|
Buy from Supplier |
|
Shimadzu Corporation
eclipse af4 device ![]() Eclipse Af4 Device, supplied by Shimadzu Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/eclipse af4 device/product/Shimadzu Corporation Average 90 stars, based on 1 article reviews
eclipse af4 device - by Bioz Stars,
2026-05
90/100 stars
|
Buy from Supplier |
|
Waters Corporation
af4 separation device ![]() Af4 Separation Device, supplied by Waters Corporation, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/af4 separation device/product/Waters Corporation Average 96 stars, based on 1 article reviews
af4 separation device - by Bioz Stars,
2026-05
96/100 stars
|
Buy from Supplier |
Journal: Journal of Virology
Article Title: Structural Studies Reveal that Endosomal Cations Promote Formation of Infectious Coxsackievirus A9 A-Particles, Facilitating RNA and VP4 Release
doi: 10.1128/jvi.01367-22
Figure Lengend Snippet: AF4 allows separation of the heterogeneous CVA9 virion population generated by 0.01% faf-BSA and endosomal ion treatments. (A) Two independent AF4 fractograms of untreated CVA9. (B) AF4 fractogram of CVA9 after 1-h treatment with 0.01% faf-BSA at 37°C. (C) AF4 fractogram of CVA9 after 3-h treatment with 0.01% faf-BSA at 37°C. (D) AF4 fractogram of CVA9 after 1-h treatment in endosomal ion environment at 37°C. (E) AF4 fractogram of CVA9 after 3-h treatment in endosomal ion environment at 37°C. (F) AF4 fractogram of CVA9 after combined treatment (0.01% faf-BSA in endosomal ionic environment) for 1 h at 37°C. In all panels, the x axis indicates time (1-mL fractions were collected at the rate of 0.5 mL/min); the y axis on the left shows light scattering (black or gray lines) and on the right the hydrodynamic radius is shown, as measured by online dynamic light scattering detector (black dots). The vertical dashed line on the left indicates the peak for intact particles and on the right the peak for expanded particles. AF4 fractions used for MS analysis are indicated by red boxes. The light scatter absorbance on all the fractograms was normalized to the highest light scatter absorbance peak, which is found in panel F.
Article Snippet: The
Techniques: Generated
Journal: Journal of Virology
Article Title: Structural Studies Reveal that Endosomal Cations Promote Formation of Infectious Coxsackievirus A9 A-Particles, Facilitating RNA and VP4 Release
doi: 10.1128/jvi.01367-22
Figure Lengend Snippet: AF4 results
Article Snippet: The
Techniques:
Journal: Analytical and Bioanalytical Chemistry
Article Title: Optimization of hyphenated asymmetric flow field-flow fractionation for the analysis of silver nanoparticles in aqueous solutions
doi: 10.1007/s00216-021-03647-3
Figure Lengend Snippet: Summary of the hyphenated AF4 experimental design. Experiments were conducted in single runs or duplicates
Article Snippet: The separation protocol comprised six consecutive steps, each characterized by its individual duration and applied cross-flow rate ( V x ) as shown in the example of Table S . For the evaluation of the quality of the separation and the characterization of the AgNP fractions’ optical properties, UV/Vis spectra were recorded using a
Techniques:
Journal: Analytical and Bioanalytical Chemistry
Article Title: Optimization of hyphenated asymmetric flow field-flow fractionation for the analysis of silver nanoparticles in aqueous solutions
doi: 10.1007/s00216-021-03647-3
Figure Lengend Snippet: Size characterization of AgNP_LA in batch and in AF4-UV/Vis-DLS system. Results obtained with the ZetaSizer Nano-ZS for the hydrodynamic diameter d H , polydispersity index PdI , and zeta-potential ζ . Parenthesized values were determined ca. 4 months after purchasing the AgNPs; all other values were determined directly after delivery. AF4 experiments were conducted within 2 months after AgNP delivery. Values shown in the table for 1:1 AgNP_LA mixtures were acquired with the best experimental conditions
Article Snippet: The separation protocol comprised six consecutive steps, each characterized by its individual duration and applied cross-flow rate ( V x ) as shown in the example of Table S . For the evaluation of the quality of the separation and the characterization of the AgNP fractions’ optical properties, UV/Vis spectra were recorded using a
Techniques:
Journal: Analytical and Bioanalytical Chemistry
Article Title: Optimization of hyphenated asymmetric flow field-flow fractionation for the analysis of silver nanoparticles in aqueous solutions
doi: 10.1007/s00216-021-03647-3
Figure Lengend Snippet: Fractograms and hydrodynamic diameter of a 1:1 mixture of 20-nm and 80-nm AgNP_LA acquired with V x = 0.5 mL/min and 0.05% v/v Mucasol as carrier solution. Black color refers to a mixture prepared in ultrapure water; red color refers to the preparation in fjord water and injection into the AF4 system 20 min after preparation
Article Snippet: The separation protocol comprised six consecutive steps, each characterized by its individual duration and applied cross-flow rate ( V x ) as shown in the example of Table S . For the evaluation of the quality of the separation and the characterization of the AgNP fractions’ optical properties, UV/Vis spectra were recorded using a
Techniques: Injection
Journal: ACS omega
Article Title: Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy.
doi: 10.1021/acsomega.1c01443
Figure Lengend Snippet: Figure 1. Scheme of the two analytical focuses of this study. (a) Empty and filled AAV8 VLP particles are analyzed via nES GEMMA and AFM. (b) AF4 liquid-phase separation enables AAV8 VLP oligomer analysis by means of nES GEMMA and AFM after fractionation.
Article Snippet: The capillary is manually cut and tapered with a homebuilt grinding machine based on the work of Tycova et al.15 AF4 experiments were performed on an Agilent 1200 system (Agilent Technologies, Santa Clara, CA, USA, auto sampler, pump, and detector), which consisted of an auto sampler, HPLC pumps, an
Techniques: Gas Phase Electrophoretic Molecular Mobility Analysis, Fractionation
Journal: ACS omega
Article Title: Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy.
doi: 10.1021/acsomega.1c01443
Figure Lengend Snippet: Figure 2. Implications of the buffer exchange treatment. (a) nES GEMMA spectra of the sample before (black trace) and after (red trace) desalting. Nonvolatile salts and other components (3−15 nm) are drastically reduced. The inset shows the shift toward small EM diameter of the AAV8 VLP’s peak. (b) AF4 fractogram of the sample with (red trace) or without (blue trace) a buffer exchange procedure. Both nES GEMMA spectra (a) and (b) show reduced signal intensity for the AAV8 VLP’s peak due to sample loss during the desalting treatment.
Article Snippet: The capillary is manually cut and tapered with a homebuilt grinding machine based on the work of Tycova et al.15 AF4 experiments were performed on an Agilent 1200 system (Agilent Technologies, Santa Clara, CA, USA, auto sampler, pump, and detector), which consisted of an auto sampler, HPLC pumps, an
Techniques: Gas Phase Electrophoretic Molecular Mobility Analysis
Journal: ACS omega
Article Title: Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy.
doi: 10.1021/acsomega.1c01443
Figure Lengend Snippet: Figure 4. Stressing procedure and fractionation of the sample. (a) AF4 fractogram of control (blue trace) and heat/mechanical-stressed (magenta trace) sample. (b) The red vertical lines mark the collected fractions: 16.5−19.2 min monomer fraction; 19.2−20.6 min dimer and trimer fraction; 20.6−25.0 min higher oligomeric fraction.
Article Snippet: The capillary is manually cut and tapered with a homebuilt grinding machine based on the work of Tycova et al.15 AF4 experiments were performed on an Agilent 1200 system (Agilent Technologies, Santa Clara, CA, USA, auto sampler, pump, and detector), which consisted of an auto sampler, HPLC pumps, an
Techniques: Fractionation, Control
Journal: ACS omega
Article Title: Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy.
doi: 10.1021/acsomega.1c01443
Figure Lengend Snippet: Figure 5. nES GEMMA spectra and AFM images of the three fractions collected with the AF4 technique (see Figure 4b). (a, b) Monomer (M) fraction; (c, d) dimer (D) and trimer (T) fraction; and (e, f) higher oligomeric (O) fraction. nES GEMMA spectra compare signals obtained for VLP-containing samples (red traces) and blanks recorded for a NH4OAc blank (black traces), respectively. nES GEMMA signals below 20 nm EM diameter putatively correspond to incompletely removed, aggregating AF4 buffer components. In (f), the arrow indicates an AAV8 VLP higher oligomer with a height of 35 nm.
Article Snippet: The capillary is manually cut and tapered with a homebuilt grinding machine based on the work of Tycova et al.15 AF4 experiments were performed on an Agilent 1200 system (Agilent Technologies, Santa Clara, CA, USA, auto sampler, pump, and detector), which consisted of an auto sampler, HPLC pumps, an
Techniques: Gas Phase Electrophoretic Molecular Mobility Analysis