Review



intraocular lens acrysof® iq aspheric iol  (alcon inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    alcon inc intraocular lens acrysof® iq aspheric iol
    Intraocular Lens Acrysof® Iq Aspheric Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof%C2%AE+iol/acrysof+iq+aspheric+iol/pm40565876-62-11-16
    Average 90 stars, based on 1 article reviews
    intraocular lens acrysof® iq aspheric iol - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Standard Deviation:

    Article Title: Comparisons of amplitude of pseudoaccommodation with aspheric yellow, spheric yellow, and spheric clear monofocal intraocular lenses
    Article Snippet: Earlier, the calculated LCA of pseudophakic eyes was 0.98 D with an AcrySof® IOL (Alcon Laboratories, Inc) and 0.74 D in a Gullstrand schematic eye at wavelengths between 500 nm and 640 nm.

    Article Title: The effect of single-piece hydrophobic acrylic intraocular lenses on the development of posterior capsule opacification.
    Article Snippet: Purpose: To evaluate the long-term effect of a single-piece hydrophobic acrylic intraocular lens (IOL), AcrySof SN60AT on the development of posterior capsule opacification (PCO) 5 years postoperatively.. Design: Prospective, observational, consecutive, case series Methods: Setting: Iladevi Cataract and IOL Research Center, Ahmedabad, India Study Population: Three hundred and ninety eyes with uncomplicated age-related cataract were included.. Patients with diabetes mellitus, glaucoma, high myopia, pseudoexfoliation, traumatic cataract, subluxated cataract, previous ocular surgeries, and allergy to dilating drops were excluded.

    Article Title: Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses
    Article Snippet: Alcon AcrySof® IOL (model SN60WF) manufactured by Alcon Laboratories, Fort Worth, Texas, USA is a single-piece, foldable, acrylic IOL which also has a blue-light filtering chromophore in addition to standard UV-light filter.



    Similar Products

    86
    Vivity Labs Inc acrysof iq vivity iol
    Acrysof Iq Vivity Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof%C2%AE+iol/acrysof+iq+vivity/pmc13123711-198-3-5
    Average 86 stars, based on 1 article reviews
    acrysof iq vivity iol - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    Vivity Labs Inc toric iols acrysof
    Toric Iols Acrysof, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof%C2%AE+iol/acrysof+iq+vivity+iol/pm40661044-29-14-15
    Average 90 stars, based on 1 article reviews
    toric iols acrysof - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vivity Labs Inc intraocular lens (iol) acrysof iq
    Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of <t>IOL</t> with monovision, as per surgery type. IOL = <t>intraocular</t> lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.
    Intraocular Lens (Iol) Acrysof Iq, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof%C2%AE+iol/acrysof+iq+vivity+iol/pmc12187150-38-12-19
    Average 90 stars, based on 1 article reviews
    intraocular lens (iol) acrysof iq - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Vivity Labs Inc acrysof iq vivity edof iol
    Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for <t>AcrySof</t> IQ Vivity) intraocular lens <t>(IOL)</t> at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).
    Acrysof Iq Vivity Edof Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof%C2%AE+iol/acrysof+iq+vivity+iol/pmc12203608-37-18-20
    Average 90 stars, based on 1 article reviews
    acrysof iq vivity edof iol - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    alcon inc intraocular lens acrysof® iq aspheric iol
    Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for <t>AcrySof</t> IQ Vivity) intraocular lens <t>(IOL)</t> at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).
    Intraocular Lens Acrysof® Iq Aspheric Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/acrysof%C2%AE+iol/acrysof+iq+aspheric+iol/pm40565876-62-11-16
    Average 90 stars, based on 1 article reviews
    intraocular lens acrysof® iq aspheric iol - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with monovision, as per surgery type. IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.

    Journal: Journal of Cataract and Refractive Surgery

    Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

    doi: 10.1097/j.jcrs.0000000000001636

    Figure Lengend Snippet: Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with monovision, as per surgery type. IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.

    Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

    Techniques: Standard Deviation

    Visual disturbances a at 3 to 6 months after bilateral implantation of IOL with monovision as per surgery type. IOL = intraocular lens; RLE = refractive lens exchange. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

    Journal: Journal of Cataract and Refractive Surgery

    Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

    doi: 10.1097/j.jcrs.0000000000001636

    Figure Lengend Snippet: Visual disturbances a at 3 to 6 months after bilateral implantation of IOL with monovision as per surgery type. IOL = intraocular lens; RLE = refractive lens exchange. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

    Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

    Techniques:

    Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens; SD, standard deviation; VA = visual acuity. a Low monovision: myopic eye >−0.75 D and ≤−0.50 D; medium monovision: myopic eye >−1.00 D and ≤−0.75 D; high monovision: myopic eye ≤−1.00 D.

    Journal: Journal of Cataract and Refractive Surgery

    Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

    doi: 10.1097/j.jcrs.0000000000001636

    Figure Lengend Snippet: Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens; SD, standard deviation; VA = visual acuity. a Low monovision: myopic eye >−0.75 D and ≤−0.50 D; medium monovision: myopic eye >−1.00 D and ≤−0.75 D; high monovision: myopic eye ≤−1.00 D.

    Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

    Techniques: Standard Deviation

    Visual disturbances at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

    Journal: Journal of Cataract and Refractive Surgery

    Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

    doi: 10.1097/j.jcrs.0000000000001636

    Figure Lengend Snippet: Visual disturbances at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

    Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

    Techniques:

    Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for AcrySof IQ Vivity) intraocular lens (IOL) at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).

    Journal: Frontiers in Medicine

    Article Title: Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration

    doi: 10.3389/fmed.2025.1505401

    Figure Lengend Snippet: Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for AcrySof IQ Vivity) intraocular lens (IOL) at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).

    Article Snippet: The aim of this clinical prospective study was to provide more clinical evidence on the use of the AcrySof IQ Vivity EDOF IOL in a series of eyes diagnosed with AMD and implanted with this model, through measuring visual acuity at different distances and assessing visual function using two patient-reported outcome questionnaires.

    Techniques: Standard Deviation