Review




Structured Review

Applied Precision Inc microscope control software
Microscope Control Software, supplied by Applied Precision Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/microscope+control+software/pmc03917226-84-11-21
Average 90 stars, based on 1 article reviews
microscope control software - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

Microscopy:

Article Title: The prevalence and origin of exoprotease-producing cells in the Bacillus subtilis biofilm
Article Snippet: Prior to the start of acquisition the cells were allowed to equilibrate on the agarose pads for 3 h. Time-lapse imaging of microcolony development and P tapA – mKate and P bpr – gfp expression was performed using a DeltaVision Core wide field microscope (Applied Precision) mounted on an Olympus IX71 inverted stand with an Olympus ×60, 1.4 NA lens and CoolSNAPHQ camera (Photometrics) with differential interference contrast (DIC) and fluorescence optics. .. For each experiment 12 independent fields were manually identified and their XYZ -positions were stored in the microscope control software (SoftWorx; Applied Precision). .. Images (512×512 pixels with 2×2 binning and 12 Z sections spaced at 1 μm) were acquired every 15 min for up to 12 h. GFP was imaged using a 100 W mercury lamp and an FITC filter set (excitation 490/20; emission 528/38) with an exposure time of 200 ms. mKate2 was imaged using a 100 W mercury lamp and a TRITC filter set (excitation 555/28; emission 617/73) with an exposure time of 300 ms. DIC images were acquired with an LED transmitted light source (Applied Precision) at 32 % intensity and exposure times between 25 and 50 ms. Post-acquisition images were rendered and analysed using omero software ( http://openmicroscopy.org ) ( Allan et al. , 2012 ).

Article Title: Phosphorylated DegU Manipulates Cell Fate Differentiation in the Bacillus subtilis Biofilm
Article Snippet: Prior to the start of acquisition, the cells were allowed to equilibrate on the agarose pads for 3 h. Time-lapse imaging of microcolony development and PtapA-gfp expression was performed using a DeltaVision Core wide-field microscope (Applied Precision) mounted on an Olympus IX71 inverted stand with an Olympus 60 (numerical aperture [NA], 1.4) lens and CoolSNAPHQ camera (Photometrics) with differential interference contrast (DIC) and fluorescence optics. .. For each experiment 12 independent fields, each containing one or two cells, were manually identified, and their xyz positions were stored in the microscope control software (softWoRx; Applied Precision). .. Data sets (512 by 512 pixels with 2-by-2 binning and 12 z sections spaced by 1 m) were acquired every 15 min for up to 12 h. Green fluorescent protein (GFP) was imaged using a 100-W Mercury lamp and a fluorescein isothiocyanate (FITC) filter set (excitation [EX] wavelength, 490/20 nm; emission [EM] wavelength, 528/38 nm) with an exposure time of 50 ms. DIC images were acquired with a light-emitting diode (LED)-transmitted light source (Applied Precision) at 32% intensity and exposure times of between 25 and 50 ms. Postacquisition data sets were rendered and analyzed using OMERO software (http://openmicroscopy.org).

Control:

Article Title: The prevalence and origin of exoprotease-producing cells in the Bacillus subtilis biofilm
Article Snippet: Prior to the start of acquisition the cells were allowed to equilibrate on the agarose pads for 3 h. Time-lapse imaging of microcolony development and P tapA – mKate and P bpr – gfp expression was performed using a DeltaVision Core wide field microscope (Applied Precision) mounted on an Olympus IX71 inverted stand with an Olympus ×60, 1.4 NA lens and CoolSNAPHQ camera (Photometrics) with differential interference contrast (DIC) and fluorescence optics. .. For each experiment 12 independent fields were manually identified and their XYZ -positions were stored in the microscope control software (SoftWorx; Applied Precision). .. Images (512×512 pixels with 2×2 binning and 12 Z sections spaced at 1 μm) were acquired every 15 min for up to 12 h. GFP was imaged using a 100 W mercury lamp and an FITC filter set (excitation 490/20; emission 528/38) with an exposure time of 200 ms. mKate2 was imaged using a 100 W mercury lamp and a TRITC filter set (excitation 555/28; emission 617/73) with an exposure time of 300 ms. DIC images were acquired with an LED transmitted light source (Applied Precision) at 32 % intensity and exposure times between 25 and 50 ms. Post-acquisition images were rendered and analysed using omero software ( http://openmicroscopy.org ) ( Allan et al. , 2012 ).

Article Title: Phosphorylated DegU Manipulates Cell Fate Differentiation in the Bacillus subtilis Biofilm
Article Snippet: Prior to the start of acquisition, the cells were allowed to equilibrate on the agarose pads for 3 h. Time-lapse imaging of microcolony development and PtapA-gfp expression was performed using a DeltaVision Core wide-field microscope (Applied Precision) mounted on an Olympus IX71 inverted stand with an Olympus 60 (numerical aperture [NA], 1.4) lens and CoolSNAPHQ camera (Photometrics) with differential interference contrast (DIC) and fluorescence optics. .. For each experiment 12 independent fields, each containing one or two cells, were manually identified, and their xyz positions were stored in the microscope control software (softWoRx; Applied Precision). .. Data sets (512 by 512 pixels with 2-by-2 binning and 12 z sections spaced by 1 m) were acquired every 15 min for up to 12 h. Green fluorescent protein (GFP) was imaged using a 100-W Mercury lamp and a fluorescein isothiocyanate (FITC) filter set (excitation [EX] wavelength, 490/20 nm; emission [EM] wavelength, 528/38 nm) with an exposure time of 50 ms. DIC images were acquired with a light-emitting diode (LED)-transmitted light source (Applied Precision) at 32% intensity and exposure times of between 25 and 50 ms. Postacquisition data sets were rendered and analyzed using OMERO software (http://openmicroscopy.org).

Software:

Article Title: The prevalence and origin of exoprotease-producing cells in the Bacillus subtilis biofilm
Article Snippet: Prior to the start of acquisition the cells were allowed to equilibrate on the agarose pads for 3 h. Time-lapse imaging of microcolony development and P tapA – mKate and P bpr – gfp expression was performed using a DeltaVision Core wide field microscope (Applied Precision) mounted on an Olympus IX71 inverted stand with an Olympus ×60, 1.4 NA lens and CoolSNAPHQ camera (Photometrics) with differential interference contrast (DIC) and fluorescence optics. .. For each experiment 12 independent fields were manually identified and their XYZ -positions were stored in the microscope control software (SoftWorx; Applied Precision). .. Images (512×512 pixels with 2×2 binning and 12 Z sections spaced at 1 μm) were acquired every 15 min for up to 12 h. GFP was imaged using a 100 W mercury lamp and an FITC filter set (excitation 490/20; emission 528/38) with an exposure time of 200 ms. mKate2 was imaged using a 100 W mercury lamp and a TRITC filter set (excitation 555/28; emission 617/73) with an exposure time of 300 ms. DIC images were acquired with an LED transmitted light source (Applied Precision) at 32 % intensity and exposure times between 25 and 50 ms. Post-acquisition images were rendered and analysed using omero software ( http://openmicroscopy.org ) ( Allan et al. , 2012 ).

Article Title: Phosphorylated DegU Manipulates Cell Fate Differentiation in the Bacillus subtilis Biofilm
Article Snippet: Prior to the start of acquisition, the cells were allowed to equilibrate on the agarose pads for 3 h. Time-lapse imaging of microcolony development and PtapA-gfp expression was performed using a DeltaVision Core wide-field microscope (Applied Precision) mounted on an Olympus IX71 inverted stand with an Olympus 60 (numerical aperture [NA], 1.4) lens and CoolSNAPHQ camera (Photometrics) with differential interference contrast (DIC) and fluorescence optics. .. For each experiment 12 independent fields, each containing one or two cells, were manually identified, and their xyz positions were stored in the microscope control software (softWoRx; Applied Precision). .. Data sets (512 by 512 pixels with 2-by-2 binning and 12 z sections spaced by 1 m) were acquired every 15 min for up to 12 h. Green fluorescent protein (GFP) was imaged using a 100-W Mercury lamp and a fluorescein isothiocyanate (FITC) filter set (excitation [EX] wavelength, 490/20 nm; emission [EM] wavelength, 528/38 nm) with an exposure time of 50 ms. DIC images were acquired with a light-emitting diode (LED)-transmitted light source (Applied Precision) at 32% intensity and exposure times of between 25 and 50 ms. Postacquisition data sets were rendered and analyzed using OMERO software (http://openmicroscopy.org).

other:

Article Title: A holin and an endopeptidase are essential for chitinolytic protein secretion in Serratia marcescens
Article Snippet: For each experiment, 12 independent fields, each containing one or two cells, were manually identified, and their xyz positions were stored in the microscope-control software (softWoRx; Applied Precision).



Similar Products

90
Carl Zeiss microscope control software zen

Microscope Control Software Zen, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/and+scan+scout+software/pmc11787697-521-13-17
Average 90 stars, based on 1 article reviews
microscope control software zen - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
Carl Zeiss micro manager open source microscope controller software

Micro Manager Open Source Microscope Controller Software, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/pm36709989-66-8-19
Average 96 stars, based on 1 article reviews
micro manager open source microscope controller software - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

96
Carl Zeiss microscope control software zen black
KEY RESOURCES TABLE
Microscope Control Software Zen Black, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/pmc09947919-429-19-6
Average 96 stars, based on 1 article reviews
microscope control software zen black - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

90
Carl Zeiss microscope control and image processing software zen
Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the <t>microscope</t> ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.
Microscope Control And Image Processing Software Zen, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/and+scan+scout+software/pmc09340547-319-14-21
Average 90 stars, based on 1 article reviews
microscope control and image processing software zen - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Carl Zeiss lsm780 confocal microscope with a temperature-controlled chamber, co 2 supply and zen software
Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the <t>microscope</t> ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.
Lsm780 Confocal Microscope With A Temperature Controlled Chamber, Co 2 Supply And Zen Software, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/controlled+cryobox+freezing+temperature+unit+zeiss/pmc09201110-57-12-14
Average 90 stars, based on 1 article reviews
lsm780 confocal microscope with a temperature-controlled chamber, co 2 supply and zen software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Carl Zeiss lsm780 confocal microscope with a temperature-controlled chamber, co2 supply and zen software
Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the <t>microscope</t> ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.
Lsm780 Confocal Microscope With A Temperature Controlled Chamber, Co2 Supply And Zen Software, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/controlled+cryobox+freezing+temperature+unit+zeiss/pm35721488-69-12-14
Average 90 stars, based on 1 article reviews
lsm780 confocal microscope with a temperature-controlled chamber, co2 supply and zen software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Carl Zeiss zen black version 2.6 microscope control software
Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the <t>microscope</t> ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.
Zen Black Version 2.6 Microscope Control Software, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/software+zen/pm32737465-301-19-16
Average 90 stars, based on 1 article reviews
zen black version 2.6 microscope control software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Carl Zeiss zen blue microscope control software
Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the <t>microscope</t> ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.
Zen Blue Microscope Control Software, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/software+zen/pm31616241-72-12-11
Average 90 stars, based on 1 article reviews
zen blue microscope control software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

96
Carl Zeiss zen microscope control software
Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the <t>microscope</t> ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.
Zen Microscope Control Software, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/zen+microscope+control+software/pmc06481736-143-16-5
Average 96 stars, based on 1 article reviews
zen microscope control software - by Bioz Stars, 2026-11
96/100 stars
  Buy from Supplier

Image Search Results


Journal: iScience

Article Title: Segregated input to thalamic areas that project differently to core and shell auditory cortical fields

doi: 10.1016/j.isci.2024.111721

Figure Lengend Snippet:

Article Snippet: The montage of tiled images was created using the "Stitching" method in the microscope control software (Zen, Carl Zeiss).

Techniques: Virus, Plasmid Preparation, Recombinant, Software, Microscopy

KEY RESOURCES TABLE

Journal: Cell reports

Article Title: Gasdermin D pore-forming activity is redox-sensitive

doi: 10.1016/j.celrep.2023.112008

Figure Lengend Snippet: KEY RESOURCES TABLE

Article Snippet: FRAP experiments were performed on a Zeiss 880 laser scanning confocal microscope using the in-built FRAP module within the microscope control software Zen Black.

Techniques: Recombinant, Protease Inhibitor, Binding Assay, Plasmid Preparation, Transfection, CyQUANT Assay, LDH Cytotoxicity Assay, Bicinchoninic Acid Protein Assay, Mutagenesis, Software, Live Cell Imaging, Laser-Scanning Microscopy, Imaging, Mass Spectrometry

Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the microscope ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.

Journal: Development (Cambridge, England)

Article Title: Imaging the onset of oscillatory signaling dynamics during mouse embryo gastrulation

doi: 10.1242/dev.200083

Figure Lengend Snippet: Light-sheet microscopy for multi-sample live imaging of mouse embryos from gastrulation to organogenesis. (A) Imaging chamber and objective configuration of the Lightsheet Z.1 (Zeiss) with two illumination light-sheets (ill.) and one detection light path (det.). The sample-containing capillary (1) is suspended from the top into the imaging chamber (2) and orientated with respect to the illumination (3) and detection (4) objectives (degrees of freedom indicated by red arrows; XYZ, translation; R, rotation). (B) Vertical section view through the sample chamber with inserted embryo culture chamber (5). The embryo culture chamber consists of a chamber lid (dark blue) and the chamber body (light blue) with membrane-covered windows for the light paths. It is connected via tubes (6) to the closed-cycle perfusion system of the microscope ( Fig. S1 ). (C) For mounting, embryos were first agarose embedded in a capillary (left), then the agarose was peeled off around the embryo, leaving only the ectoplacental cone embedded to allow growth during culture (right). (D) Bright-field images of an embryo developing on the customized light-sheet microscope (anterior towards the left). The experiment starts at mid-streak stage at E6.5. Morphological features are the allantois (a), the head fold (hf), somites (s) and foregut pocket (fg). Scale bar: 500 μm. (E) Examples of embryos after culture on the microscope: (i) LuVeLu reporter imaging ( z -stacks with 7.5 μm spacing, 100 slices per sample, 300 ms exposure time with 2.0% 50 mW 514 nm laser and 10 min imaging interval. n =6); (ii) R26-H2BmCherry reporter imaging ( z -stacks with 7.5 μm spacing, 120 slices per sample, 200 ms exposure time with 1.2% 20 mW 561 nm laser and 10 min imaging interval. n =4); (iii) cultured on microscope without imaging ( n =9); (iv) roller culture ( n =29); and (v) in utero developed control embryos dissected at E8.5 ( n =12). For all embryos, a hybridization-chain reaction (HCR)-based in situ mRNA hybridization was performed for following genes: Msgn1 (cyan), a marker for presomitic mesoderm; Shh (yellow), expressed in notochord and the floorplate of the neural tube; and Uncx4.1 (magenta), marking the anterior-posterior subdivisions of the somites. Scale bar: 200 μm. Brightness and contrast were set identically for samples i, iii, iv and v, but adjusted separately for ii. (F) SPIM-for-4 multi-sample holder. Four sample capillaries are positioned in the sample holder (7), which is mounted on the Z.1 stage using the standard sample holder disc for syringes (8). A capillary cap is glued to the top of each capillary (9; in top view on the right). With a hex key, each capillary can be turned individually around its long axis (small R), while the rotation drive of the microscope stage allows for switching between samples (large R). (G) Horizontal section view through the imaging chamber in the plane of the light path. Sample capillaries (red circles) in the SPIM-for-4 multi-sample holder do not interfere with the light paths during imaging and the holder is compatible with the embryo culture chamber. CAD drawings of Z.1 microscope parts are courtesy of Carl Zeiss Microscopy.

Article Snippet: During acquisition, both images were combined using a mean fusion algorithm provided with the microscope control and image processing software ZEN (Carl Zeiss).

Techniques: Microscopy, Imaging, Embryo Culture, Membrane, Cell Culture, In Utero, Control, Hybridization, In Situ, Marker