Review




Structured Review

PolyLC INC polycat
Polycat, supplied by PolyLC INC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/polycat/pmc09130532-375-24-28
Average 90 stars, based on 1 article reviews
polycat - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Mind Your Spectra: Points to be Aware of When Validating the Identification of Isobaric Histone Peptidoforms.
Article Snippet: 75 μm) packed in-house with Polycat A (2 μm, 1000 Å, PolyLc inc.) to a length of 30 cm.

Article Title: Prioritization of The Zinc finger domain within BCL11A by the Amelioration capability of hemoglobinopathies using CRISPR-Cas9 technology
Article Snippet: Hb tetramers were separated using two cation-exchange columns (PolyCAT A, PolyLC, Columbia, MD) with elution carried out by a gradient mixture of solution A [20 mM Bis-Tris and 2 mM KCN (pH 6.5)] and solution B [20 mM Bis-Tris, 2 mM KCN, and 250 mM NaCl (pH 6.8)].

Article Title: The protein organization of a red blood cell.
Article Snippet: Triple phase ion exchange (WWC) Three columns, each 2003 4.6 mm ID, particle diameter 5 mm, pore diameter 100 Å, were connected in series in the following order: two PolyWAX LP columns followed by a single PolyCAT A (PolyLC, Inc, Columbia, MD).

Article Title: Quantitation of Single and Combinatorial Histone Modifications by Integrated Chromatography of Bottom-up Peptides and Middle-down Polypeptide Tails.
Article Snippet: The analysis of histone posttranslational modifications (PTMs) by mass spectrometry (MS) has been critical to the advancement of the field of epigenetics.. The most sensitive and accurate workflow is similar to the canonical proteomics analysis workflow (bottom-up MS), where histones are digested into short peptides (4-20 aa) and quantitated in extracted ion chromatograms.. However, this limits the ability to detect even very common co-occurrences of modifications on histone proteins, preventing biological interpretation of PTM crosstalk.

Article Title: A pan-plant protein complex map reveals deep conservation and novel assemblies
Article Snippet: Triple phase ion exchange Three columns, each 200 × 4.6 mm ID, particle diameter 5 μm, pore diameter 100 Å, were connected in series in the following order: two PolyWAX LP columns followed by a single PolyCAT A (PolyLC, Inc, Columbia, MD).

Article Title: Mind Your Spectra: Points to be Aware of when Validating the Identification of Isobaric Histone Peptidoforms
Article Snippet: 75 μm) packed in-house with Polycat A (2 μm, 1000 Å, PolyLc inc.) to a length of 30 cm.

Article Title: VerteBrain reveals novel neural and non-neural protein assemblies conserved across vertebrate evolution
Article Snippet: Poly CATWAX A (PolyLC Mixed-Bed WAX-WCX) 200 3 4.6 mm ID, Particle diameter 5 mm, pore diameter 100 A ° (PolyLC Inc., Columbia, MD) comprises cation-exchange (PolyCAT A) and anion-exchange (PolyWAX LP) materials in equal amounts.

Article Title: High-level correction of the sickle mutation is amplified in vivo during erythroid differentiation
Article Snippet: Upon thawing, cell lysates were diluted 1:10 in mobile phase A and characterized by high-performance liquid chromatography (HPLC; Infinity 1260, Agilent) using a weak cation-exchange column (PolyCAT A, PolyLC).



Similar Products

90
Ciphergen inc wcx2 (weak cationic exchange) proteinchip arrays
Wcx2 (Weak Cationic Exchange) Proteinchip Arrays, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/wcx+2/pmc02275230-183-9-17
Average 90 stars, based on 1 article reviews
wcx2 (weak cationic exchange) proteinchip arrays - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Ciphergen inc seldi proteinchip arrays weak cation exchange (wcx-2
Seldi Proteinchip Arrays Weak Cation Exchange (Wcx 2, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/seldi+proteinchip/pmc03312904-100-6-10
Average 90 stars, based on 1 article reviews
seldi proteinchip arrays weak cation exchange (wcx-2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

93
Bio-Rad proteinchip cm10 weak cation exchanger array chip
Proteinchip Cm10 Weak Cation Exchanger Array Chip, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pm26011147-79-9-15
Average 93 stars, based on 1 article reviews
proteinchip cm10 weak cation exchanger array chip - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchanger array
Weak Cation Exchanger Array, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pm26426938-59-1-7
Average 93 stars, based on 1 article reviews
weak cation exchanger array - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchange cm10 proteinchip arrays
Weak Cation Exchange Cm10 Proteinchip Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pmc04016244-77-17-22
Average 93 stars, based on 1 article reviews
weak cation exchange cm10 proteinchip arrays - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchanger
Weak Cation Exchanger, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pm23289400-82-19-26
Average 93 stars, based on 1 article reviews
weak cation exchanger - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

90
Bio-Rad cm10 (weak cation exchange array
Cm10 (Weak Cation Exchange Array, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/cm10/pm21145706-68-15-11
Average 90 stars, based on 1 article reviews
cm10 (weak cation exchange array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Ciphergen inc proteinchip arrays: weak cation exchange (wcx2
Proteinchip Arrays: Weak Cation Exchange (Wcx2, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/wcx+2/pm21328600-81-22-21
Average 90 stars, based on 1 article reviews
proteinchip arrays: weak cation exchange (wcx2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchange proteinchip cm10 arrays
L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
Weak Cation Exchange Proteinchip Cm10 Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pmc03317844-132-0-5
Average 93 stars, based on 1 article reviews
weak cation exchange proteinchip cm10 arrays - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

Image Search Results


L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on CM10 array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).

Journal: Proteome Science

Article Title: S100A10 protein expression is associated with oxaliplatin sensitivity in human colorectal cancer cells

doi: 10.1186/1477-5956-9-76

Figure Lengend Snippet: L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on CM10 array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).

Article Snippet: Weak cation-exchange ProteinChip CM10 arrays (Bio-Rad Laboratories, Hercules, CA, USA) were used for protein profiling.

Techniques: Selection, Expressing

Characterization of the 11.1 kDa protein . (A) Estimation of pI of the 11.1 kDa protein. The affinity of the 11.1 kDa protein (indicated by the arrow) to a CM10 array changed with a pH range of 3.0-10.0. (B) Estimation of experimental molecular mass of the 11.1 kDa protein (indicated by the arrow). Bovine insulin (5733.5 Da) and equine cytochrome C (12361.0 Da) were calibrants for internal calibration.

Journal: Proteome Science

Article Title: S100A10 protein expression is associated with oxaliplatin sensitivity in human colorectal cancer cells

doi: 10.1186/1477-5956-9-76

Figure Lengend Snippet: Characterization of the 11.1 kDa protein . (A) Estimation of pI of the 11.1 kDa protein. The affinity of the 11.1 kDa protein (indicated by the arrow) to a CM10 array changed with a pH range of 3.0-10.0. (B) Estimation of experimental molecular mass of the 11.1 kDa protein (indicated by the arrow). Bovine insulin (5733.5 Da) and equine cytochrome C (12361.0 Da) were calibrants for internal calibration.

Article Snippet: Weak cation-exchange ProteinChip CM10 arrays (Bio-Rad Laboratories, Hercules, CA, USA) were used for protein profiling.

Techniques: