Review




Structured Review

Bioyong Technologies Inc weak cation exchange magnetic bead wcx mb kit
Weak Cation Exchange Magnetic Bead Wcx Mb Kit, supplied by Bioyong Technologies Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/wcx+magnetic+bead+kit/pmc05557491-92-1-11
Average 90 stars, based on 1 article reviews
weak cation exchange magnetic bead wcx mb kit - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Proteomic study of benign and malignant pleural effusion.
Article Snippet: Abbreviations WCX-MB Weak cationic-exchanger magnetic bead MALDI-TOF-MS Matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry GA Genetic algorithm CARD9 Caspase recruitment domain-containing protein 9 PPV Positive predictive value NPV Negative predictive value nano-LC/ESI-MS/MS Nano-liquid chromatography– electrospray ionization–tandem mass spectrometry NSCLC Non-small cell lung cancer NF-kB Nuclear factor-kappaB MAPK Mitogen-activated protein kinase

Article Title: Salivary peptidome profiling analysis for occurrence of new carious lesions in patients with severe early childhood caries
Article Snippet: A weak cation exchange magnetic bead (WCX MB) kit was used (Bioyong Tech, Beijing, China).

Article Title: Longitudinal investigation of salivary proteomic profiles in the development of early childhood caries.
Article Snippet: Accepted Manuscript Title: Longitudinal Investigation of Salivary Proteomic Profiles in the Development of Early Childhood Caries Authors: Shuang Ao, Xiangyu Sun, Xiangru Shi, Xin Huang, Feng Chen, Shuguo Zheng PII: S0300-5712(17)30090-8 DOI: http://dx.doi.org/doi:10.1016/j.jdent.2017.04.006 Reference: JJOD 2758 To appear in: Journal of Dentistry Received date: 9-2-2017 Revised date: 13-4-2017 Accepted date: 18-4-2017 Please cite this article as: Ao Shuang, Sun Xiangyu, Shi Xiangru, Huang Xin, Chen Feng, Zheng Shuguo.Longitudinal Investigation of Salivary Proteomic Profiles in the Development of Early Childhood Caries.Journal of Dentistry http://dx.doi.org/10.1016/j.jdent.2017.04.006 This is a PDF file of an unedited manuscript that has been accepted for publication.. As a service to our customers we are providing this early version of the manuscript.. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form.

Article Title: Analysis of salivary proteomic biomarkers for the surveillance of changes in high-risk status of early childhood caries
Article Snippet: Magnetic bead kits (Bioyong Tech, Inc., Beijing, China) were used to analyse saliva samples.

Article Title: The Urinary Peptidome as a Noninvasive Biomarker Development Strategy for Prenatal Screening of Down's Syndrome.
Article Snippet: Prenatal screening for Down’s syndrome based on maternal age, ultrasound measures, and maternal serum biomarkers is recommended worldwide, but the false-positive rate and poor diagnostic performance of these screening tests remain problematic.. Genetic analysis of cell-free DNA in maternal blood has been developed as a new prenatal screening for Down’s syndrome, but it has a number of limitations, including turnaround time and cost.. Prenatal screening diagnostic innovation calls for new tests that are noninvasive, accurate, and affordable.

Article Title: Magnetic bead-based salivary peptidome profiling analysis for severe early childhood caries.
Article Snippet: Objective: To investigate the differential salivary protein expression profiles between children with severe early childhood caries (S-ECC) and caries-free (CF) children at the age of 3 years.. Methods: We used matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry (MALDI-TOF MS) combined with weak cation exchange magnetic beads, and peptide mass fingerprints were created by scanning mass spectrometry signals.. Salivary samples from 20 children were analyzed (10 for each group).

Matrix-assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry:

Article Title: Magnetic bead-based salivary peptidome profiling for periodontal-orthodontic treatment
Article Snippet: .. The WCX magnetic bead kit (SPE-C; Bioyong Tech, Beijing, China), alpha-cyano-4-hydroxycinnamic acid (HCCA), MALDI-TOF MS (Bruker Bio-sciences, Bremen, Germany), 100% ethanol (chromatographic grade), and 100% acetone (chromatographic grade) were freshly prepared. ..

Magnetic Beads:

Article Title: Identification of salivary peptidomic biomarkers in chronic kidney disease patients undergoing haemodialysis.
Article Snippet: Background: Chronic kidney disease (CKD) is a worldwide public health problem.. To detect discriminating salivary peptide profiles between CKD patients undergoing haemodialysis (HD) and healthy controls (HCs) and to screen candidate biomarkers for CKD, we preliminarily explored the diagnostic potentiality of saliva.. Methods: Saliva samples from 30 CKD HD patients and 35 HCs were analysed using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) combined with weak cation exchange magnetic beads.



Similar Products

90
Ciphergen inc wcx2 (weak cationic exchange) proteinchip arrays
Wcx2 (Weak Cationic Exchange) Proteinchip Arrays, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/wcx+2/pmc02275230-183-9-17
Average 90 stars, based on 1 article reviews
wcx2 (weak cationic exchange) proteinchip arrays - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Ciphergen inc seldi proteinchip arrays weak cation exchange (wcx-2
Seldi Proteinchip Arrays Weak Cation Exchange (Wcx 2, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/seldi+proteinchip/pmc03312904-100-6-10
Average 90 stars, based on 1 article reviews
seldi proteinchip arrays weak cation exchange (wcx-2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

93
Bio-Rad proteinchip cm10 weak cation exchanger array chip
Proteinchip Cm10 Weak Cation Exchanger Array Chip, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pm26011147-79-9-15
Average 93 stars, based on 1 article reviews
proteinchip cm10 weak cation exchanger array chip - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchanger array
Weak Cation Exchanger Array, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pm26426938-59-1-7
Average 93 stars, based on 1 article reviews
weak cation exchanger array - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchange cm10 proteinchip arrays
Weak Cation Exchange Cm10 Proteinchip Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pmc04016244-77-17-22
Average 93 stars, based on 1 article reviews
weak cation exchange cm10 proteinchip arrays - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchanger
Weak Cation Exchanger, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pm23289400-82-19-26
Average 93 stars, based on 1 article reviews
weak cation exchanger - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

90
Bio-Rad cm10 (weak cation exchange array
Cm10 (Weak Cation Exchange Array, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/cm10/pm21145706-68-15-11
Average 90 stars, based on 1 article reviews
cm10 (weak cation exchange array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Ciphergen inc proteinchip arrays: weak cation exchange (wcx2
Proteinchip Arrays: Weak Cation Exchange (Wcx2, supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/wcx+2/pm21328600-81-22-21
Average 90 stars, based on 1 article reviews
proteinchip arrays: weak cation exchange (wcx2 - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

93
Bio-Rad weak cation exchange proteinchip cm10 arrays
L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
Weak Cation Exchange Proteinchip Cm10 Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/weak+cation+exchanger+array/ProteinChip+CM10+Arrays/pmc03317844-132-0-5
Average 93 stars, based on 1 article reviews
weak cation exchange proteinchip cm10 arrays - by Bioz Stars, 2026-11
93/100 stars
  Buy from Supplier

Image Search Results


L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on CM10 array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).

Journal: Proteome Science

Article Title: S100A10 protein expression is associated with oxaliplatin sensitivity in human colorectal cancer cells

doi: 10.1186/1477-5956-9-76

Figure Lengend Snippet: L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on CM10 array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).

Article Snippet: Weak cation-exchange ProteinChip CM10 arrays (Bio-Rad Laboratories, Hercules, CA, USA) were used for protein profiling.

Techniques: Selection, Expressing

Characterization of the 11.1 kDa protein . (A) Estimation of pI of the 11.1 kDa protein. The affinity of the 11.1 kDa protein (indicated by the arrow) to a CM10 array changed with a pH range of 3.0-10.0. (B) Estimation of experimental molecular mass of the 11.1 kDa protein (indicated by the arrow). Bovine insulin (5733.5 Da) and equine cytochrome C (12361.0 Da) were calibrants for internal calibration.

Journal: Proteome Science

Article Title: S100A10 protein expression is associated with oxaliplatin sensitivity in human colorectal cancer cells

doi: 10.1186/1477-5956-9-76

Figure Lengend Snippet: Characterization of the 11.1 kDa protein . (A) Estimation of pI of the 11.1 kDa protein. The affinity of the 11.1 kDa protein (indicated by the arrow) to a CM10 array changed with a pH range of 3.0-10.0. (B) Estimation of experimental molecular mass of the 11.1 kDa protein (indicated by the arrow). Bovine insulin (5733.5 Da) and equine cytochrome C (12361.0 Da) were calibrants for internal calibration.

Article Snippet: Weak cation-exchange ProteinChip CM10 arrays (Bio-Rad Laboratories, Hercules, CA, USA) were used for protein profiling.

Techniques: