Review



microfluidic single-cell resolution western blot device  (Vortex Biosciences)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Vortex Biosciences microfluidic single-cell resolution western blot device
    Schematic representation (a) and experimental setup (b) of a piezo-ring-on-chip <t>microfluidic</t> device for depositing sample on a MALDI-MS target plate in small 40 nL volumes. Reprinted with permission from Tsao, C.-W.; Lei, I. C.; Chen, P.-Y.; Yang, Y.-L. Analyst 2018, 143, 981–988 (ref 20). Copyright 2018 Centre National de la Recherche Scientifique (CNRS) and The Royal Society of Chemistry.
    Microfluidic Single Cell Resolution Western Blot Device, supplied by Vortex Biosciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/microfluidic+device/pmc07393861-334-3-55
    Average 90 stars, based on 1 article reviews
    microfluidic single-cell resolution western blot device - by Bioz Stars, 2026-11
    90/100 stars

    Images

    1) Product Images from "Protein and Proteome Measurements with Microfluidic Chips"

    Article Title: Protein and Proteome Measurements with Microfluidic Chips

    Journal: Analytical chemistry

    doi: 10.1021/acs.analchem.9b04711

    Schematic representation (a) and experimental setup (b) of a piezo-ring-on-chip microfluidic device for depositing sample on a MALDI-MS target plate in small 40 nL volumes. Reprinted with permission from Tsao, C.-W.; Lei, I. C.; Chen, P.-Y.; Yang, Y.-L. Analyst 2018, 143, 981–988 (ref 20). Copyright 2018 Centre National de la Recherche Scientifique (CNRS) and The Royal Society of Chemistry.
    Figure Legend Snippet: Schematic representation (a) and experimental setup (b) of a piezo-ring-on-chip microfluidic device for depositing sample on a MALDI-MS target plate in small 40 nL volumes. Reprinted with permission from Tsao, C.-W.; Lei, I. C.; Chen, P.-Y.; Yang, Y.-L. Analyst 2018, 143, 981–988 (ref 20). Copyright 2018 Centre National de la Recherche Scientifique (CNRS) and The Royal Society of Chemistry.

    Techniques Used:

    Integrated platform composed of a microfluidic device and a His/Myc-double-tagged ORF library spotted on glass for monitoring the parallel expressions and phosphorylation of thousands of proteins. One assay unit contains DNA and protein chambers isolated by valves. (a) The microfluidic device. (b) Following incubation with a mammalian reticulocyte lysate, the target proteins are expressed in the DNA chambers, diffused, and immobilized in the protein chambers via a His tag. (c) Proteins expressed in mammalian cell lysates; the enzymes that have autophosphorylation activity are expected to be functional and undergo autophosphorylation during expression. (d, e) The proteins and the p-Tyr proteins are both quantified in situ using Cy3-coupled anti-Myc antibodies and Cy5-coupled antiphosphorylated-Tyr antibodies, respectively. Adapted with permission from Nevenzal, H.; Noach-Hirsh, M.; Skornik-Bustan, O.; Brio, L.; Barbiro-Michaely, E.; Glick, Y.; Avrahami, D.; Lahmi, R.; Tzur, A.; Gerber, D. Commun. Biol. 2019, 2, 42 (ref 27). Copyright 2019 granted underCreative Commons CC BY license (https://creativecommons.org/licenses/by/4.0/).
    Figure Legend Snippet: Integrated platform composed of a microfluidic device and a His/Myc-double-tagged ORF library spotted on glass for monitoring the parallel expressions and phosphorylation of thousands of proteins. One assay unit contains DNA and protein chambers isolated by valves. (a) The microfluidic device. (b) Following incubation with a mammalian reticulocyte lysate, the target proteins are expressed in the DNA chambers, diffused, and immobilized in the protein chambers via a His tag. (c) Proteins expressed in mammalian cell lysates; the enzymes that have autophosphorylation activity are expected to be functional and undergo autophosphorylation during expression. (d, e) The proteins and the p-Tyr proteins are both quantified in situ using Cy3-coupled anti-Myc antibodies and Cy5-coupled antiphosphorylated-Tyr antibodies, respectively. Adapted with permission from Nevenzal, H.; Noach-Hirsh, M.; Skornik-Bustan, O.; Brio, L.; Barbiro-Michaely, E.; Glick, Y.; Avrahami, D.; Lahmi, R.; Tzur, A.; Gerber, D. Commun. Biol. 2019, 2, 42 (ref 27). Copyright 2019 granted underCreative Commons CC BY license (https://creativecommons.org/licenses/by/4.0/).

    Techniques Used: Isolation, Incubation, Activity Assay, Functional Assay, Expressing, In Situ

    Schematic representation of a microfluidic chip for performing HDX of proteins on subsecond time scales. Reprinted from Svejdal, R. R.; Dickinson, E. R.; Sticker, D.; Kutter, J. P.; Rand, K. D. Anal. Chem. 2019, 91, 1309–1317 (ref 29). Copyright 2018 American Chemical Society.
    Figure Legend Snippet: Schematic representation of a microfluidic chip for performing HDX of proteins on subsecond time scales. Reprinted from Svejdal, R. R.; Dickinson, E. R.; Sticker, D.; Kutter, J. P.; Rand, K. D. Anal. Chem. 2019, 91, 1309–1317 (ref 29). Copyright 2018 American Chemical Society.

    Techniques Used:

    Microfluidic IMER chip for proteolytic digestion with trypsin adsorbed on the porous surface of PDMS channels. (a) Microfluidic chip. (b) Multiplexed design of the IMER channels. (c) Serpentine IMER channels. Reproduced with permission from Kecskemeti, A.; Nagy, C.; Csosz, E.; Kallo, G.; Gaspar, A. Prot. Clin. Appl. 2017, 11, 11–12, 1700055 (ref 39). Copyright 2017 John Wiley and Sons.
    Figure Legend Snippet: Microfluidic IMER chip for proteolytic digestion with trypsin adsorbed on the porous surface of PDMS channels. (a) Microfluidic chip. (b) Multiplexed design of the IMER channels. (c) Serpentine IMER channels. Reproduced with permission from Kecskemeti, A.; Nagy, C.; Csosz, E.; Kallo, G.; Gaspar, A. Prot. Clin. Appl. 2017, 11, 11–12, 1700055 (ref 39). Copyright 2017 John Wiley and Sons.

    Techniques Used:

    Microfluidic device for desalting protein samples with a silica isoporous membrane. (a) Microfluidic assembly. (b) Serpentine PMMA channel for sample delivery. (c) Representation of the desalting process through the membrane. Reproduced from Wu, W.; Zhang, D.; Chen, K.; Zhou, P.; Zhao, M.; Qiao, L.; Su, B. Anal. Chem. 2018, 90, 14395–14401 (ref 42). Copyright 2018 American Chemical Society.
    Figure Legend Snippet: Microfluidic device for desalting protein samples with a silica isoporous membrane. (a) Microfluidic assembly. (b) Serpentine PMMA channel for sample delivery. (c) Representation of the desalting process through the membrane. Reproduced from Wu, W.; Zhang, D.; Chen, K.; Zhou, P.; Zhao, M.; Qiao, L.; Su, B. Anal. Chem. 2018, 90, 14395–14401 (ref 42). Copyright 2018 American Chemical Society.

    Techniques Used:

    Workflow for selecting THP-1 cells with a microfluidic cell sorter device to test the ability to perform proteomic profiling of rare CTCs. Cell collection was performed in tubes with various coatings to enable different processing procedures prior to LC-MS/MS analysis: Group 1, 1000 cells in a BSA-coated tube digested with medium; Group 2, 1000 cells in a BSA-coated tube with the medium removed; Group 3, 1000 cells in a hydrophilic-coated tube with the medium removed; Group 4, 100 cells in a BSA-coated tube digested with medium; Group 5, 100 cells in a BSA-coated tube with the medium removed. Reprinted with permission from Kasuga, K.; Katoh, Y.; Nagase, K.; Igarashi, K. Proteomics 2017, 17, 1600420 (ref 52). Copyright 2017 John Wiley and Sons.
    Figure Legend Snippet: Workflow for selecting THP-1 cells with a microfluidic cell sorter device to test the ability to perform proteomic profiling of rare CTCs. Cell collection was performed in tubes with various coatings to enable different processing procedures prior to LC-MS/MS analysis: Group 1, 1000 cells in a BSA-coated tube digested with medium; Group 2, 1000 cells in a BSA-coated tube with the medium removed; Group 3, 1000 cells in a hydrophilic-coated tube with the medium removed; Group 4, 100 cells in a BSA-coated tube digested with medium; Group 5, 100 cells in a BSA-coated tube with the medium removed. Reprinted with permission from Kasuga, K.; Katoh, Y.; Nagase, K.; Igarashi, K. Proteomics 2017, 17, 1600420 (ref 52). Copyright 2017 John Wiley and Sons.

    Techniques Used: Liquid Chromatography with Mass Spectroscopy

    Schematic diagram of a multiplexed immunoassay microfluidic chip for analyzing cell-secreted cytokines. The chip contains 16 units, each comprising a cell culture chamber, transfer pump for cell culture media, and a chamber with 10 antibody capture spots for analyzing the secreted cytokines in the cell supernatant. The control layer (red) modulates the fluid flow (blue) in the cell/immunoassay layer. Reprinted with permission from Kaestli, A. J.; Junkin, M.; Tay, S. Lab Chip 2017, 17, 4124–4133 (ref 61). Copyright 2017 The Royal Society of Chemistry.
    Figure Legend Snippet: Schematic diagram of a multiplexed immunoassay microfluidic chip for analyzing cell-secreted cytokines. The chip contains 16 units, each comprising a cell culture chamber, transfer pump for cell culture media, and a chamber with 10 antibody capture spots for analyzing the secreted cytokines in the cell supernatant. The control layer (red) modulates the fluid flow (blue) in the cell/immunoassay layer. Reprinted with permission from Kaestli, A. J.; Junkin, M.; Tay, S. Lab Chip 2017, 17, 4124–4133 (ref 61). Copyright 2017 The Royal Society of Chemistry.

    Techniques Used: Cell Culture

    Microfluidic chip incorporating a reactor that enables cell culture, stimulation, and cell recovery for monitoring proteome-level fast cellular responses by mass spectrometry (a). COMSOL simulation of transversal delivery of a stimulant solution to the cell chamber (b–d). Reprinted with permission from Lazar, I. M.; Deng, J.; Stremler, M. A.; Ahuja, S. Microsystems & Nanoengineering 2019, 5, 7 (ref 68). Copyright granted under Creative Commons CC BY license (https://creativecommons.org/licenses/by/4.0/).
    Figure Legend Snippet: Microfluidic chip incorporating a reactor that enables cell culture, stimulation, and cell recovery for monitoring proteome-level fast cellular responses by mass spectrometry (a). COMSOL simulation of transversal delivery of a stimulant solution to the cell chamber (b–d). Reprinted with permission from Lazar, I. M.; Deng, J.; Stremler, M. A.; Ahuja, S. Microsystems & Nanoengineering 2019, 5, 7 (ref 68). Copyright granted under Creative Commons CC BY license (https://creativecommons.org/licenses/by/4.0/).

    Techniques Used: Cell Culture, Mass Spectrometry

    Related Articles

    Purification:

    Article Title: Apparatus and method for label-free analysis of rare cells from bodily fluids
    Article Snippet: .. In one embodiment, the purification device 12 may be in the form of a microfluidic chip that is available from Vortex BioSciences, Inc. (Palo Alto, Calif.). ..

    Cell Isolation:

    Article Title: Toward Microfluidic Label-Free Isolation and Enumeration of Circulating Tumor Cells from Blood Samples.
    Article Snippet: .. For cancer cell isolation from blood samples, the microfluidic chips and manifold for interfacing with fluidic tubing were Cytometry Part A 2019 3 provided by Vortex Biosciences (17). ..

    Cytometry:

    Article Title: Toward Microfluidic Label-Free Isolation and Enumeration of Circulating Tumor Cells from Blood Samples.
    Article Snippet: .. For cancer cell isolation from blood samples, the microfluidic chips and manifold for interfacing with fluidic tubing were Cytometry Part A 2019 3 provided by Vortex Biosciences (17). ..

    High Throughput Screening Assay:

    Article Title: Integrated system for isolation and emulsification of particles and cells
    Article Snippet: Existing CTC isolation technologies that rely on physical properties of CTCs such as size based filtration, acoustic wave deflection, dielectrophoresis and size based inertial separation are still limited in throughput, pre-processing steps such as RBC-lysis and low sample purity. .. More recently, a microfluidic-based device called the Vortex Chip (Vortex Biosciences, Inc., Menlo Park, Calif.) has demonstrated an ability to use high throughput inertial microfluidics and microscale vortices to passively enrich large cells such as CTCs at high purity from large volumes of blood. ..

    FACS:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    Single Cell:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    Western Blot:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    Staining:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    Lysis:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    Polyacrylamide Gel Electrophoresis:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    Immunostaining:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: .. The CTCs are larger (15-25 μm) than the normal surrounding cells, and the development of devices that enabled their capture (based on physical properties-traps, hydrodynamic, DEP or acoustic cell sorting; and, based on immunoaffinity methods-immunomagnetic or immunocapture on microstructures) and controlled-release from the capture surface (chemical or field-triggered) was particularly pursued.47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al.49 The microfluidic workflow included CTC enrichment from 2-4 mL blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μm diameter) and CTC lysis in the well, followed by PAGE separation (within Page 16 of 43 ACS Paragon Plus Environment Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 17 seconds), covalent immobilization of proteins to the gel and Western immunostaining of the panel of 12 proteins. ..

    other:

    Article Title: Protein and Proteome Measurements with Microfluidic Chips
    Article Snippet: 47 Recently, a microfluidic single-cell resolution Western blot device and method capable of capturing a panel of 12 proteins from ER+ and HER2+ circulating breast cancer cells was reported by Sinkala et al. 49 The microfluidic workflow included CTC enrichment from 2 to 4 mL of blood using a commercial size and deformability-selective microfluidic device (Vortex Biosciences), Hoechst/nuclear staining for visualizing the putative CTCs, single-cell CTC deposition into a microwell (50 μ m diameter), and CTC lysis in the well, followed by PAGE separation (within seconds), covalent immobilization of proteins to the gel, and Western immunostaining of the panel of 12 proteins.



    Similar Products

    86
    Scientific Industries Inc vortex genie 2 device
    Vortex Genie 2 Device, supplied by Scientific Industries Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/mixer+vortex+%EA%B8%B0%EA%B8%B0%EB%8A%94+%EC%82%AC%EC%9A%A9%EB%90%9C+%EC%8B%A4%ED%97%98%EC%97%90/pmc12803027-91-39-42
    Average 86 stars, based on 1 article reviews
    vortex genie 2 device - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    VELP Scientifica vortex device
    Vortex Device, supplied by VELP Scientifica, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/pm41418396-62-5-7
    Average 86 stars, based on 1 article reviews
    vortex device - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    86
    Daihan Scientific vortex device
    Vortex Device, supplied by Daihan Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/mixer+vortex/10__1007_slash_s11694___025___03580___4-90-39-42
    Average 86 stars, based on 1 article reviews
    vortex device - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    90
    SCILOGEX Inc vortex device scilogex mx-s vortex mixer
    Vortex Device Scilogex Mx S Vortex Mixer, supplied by SCILOGEX Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/vortex+mixer+scilogex+mx+s/pm40560267-123-25-27
    Average 90 stars, based on 1 article reviews
    vortex device scilogex mx-s vortex mixer - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Fanem Ltda vortex device
    Vortex Device, supplied by Fanem Ltda, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/vortex+apparatus+fanem/pm40332205-63-35-37
    Average 90 stars, based on 1 article reviews
    vortex device - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Heidolph Instruments vortex device
    Vortex Device, supplied by Heidolph Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/vortex+mixer+heidolph/pm40323540-77-20-22
    Average 90 stars, based on 1 article reviews
    vortex device - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Thistle Scientific Ltd vortex device csl-vortex
    Vortex Device Csl Vortex, supplied by Thistle Scientific Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/vortex+device+csl+vortex/pm39915581-127-13-16
    Average 90 stars, based on 1 article reviews
    vortex device csl-vortex - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Coriolis Pharma vortex fluidic device
    Vortex Fluidic Device, supplied by Coriolis Pharma, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/vortex+device/vortex+fluidic+device/10__1002_slash_smsc__202400449-46-10-34
    Average 90 stars, based on 1 article reviews
    vortex fluidic device - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results