    Structured Review

    Psychology Software Tools hyperion digital projection system
    Hyperion Digital Projection System, supplied by Psychology Software Tools, used in various techniques. Bioz Stars score: 94/100, based on 38 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/visual+stimulation+task/Hyperion/pm39854199-76-35-39
    Average 94 stars, based on 38 article reviews
    hyperion digital projection system - by Bioz Stars, 2026-11
    94/100 stars

    Images

    Related Articles

    Magnetic Resonance Imaging:

    Article Title: An open-access multi-site fMRI dataset for investigating conscious visual perception
    Article Snippet: .. At Yale, stimuli were presented using a Hyperion projection system (Psychology Software Tools; 1920 × 1080 pixels, 60 Hz; viewing distance ~113 cm) and an MRI-compatible BOLDscreen 32” IPS LCD monitor (Cambridge Research Systems; 1920 × 1080 pixels, 60 Hz; viewing distance ~134 cm) at the DCCN. ..

    Article Title: Meta-awareness, mind-wandering, and the control of automatic external and internal orientations of attention.
    Article Snippet: .. Visual stimuli and video content were displayed using PsychoPy2 66 and projected onto a screen 80 cm from the eyes through an angled mirror mounted on top of the head coil using a digital light processing projector (Hyperion MRI Digital Projection System, Psychology Software Tools, Sharpsburg, PA, USA) with a resolution of 1920 x 1080 pixels at 60 Hz. .. Audio for each video clip was delivered with MRI-compatible Sensimetrics in-ear headphones.

    other:

    Article Title: A multi-session simultaneous EEG-fMRI dataset with repeated experience sampling
    Article Snippet: A screen displaying visual stimuli was rear projected using a Psychology Software Tools Hyperion projector at the end of the scanner bore.

    Article Title: Spatial and semantic memory reorganize a hippocampal long-axis gradient.
    Article Snippet: The stimuli were presented using a Psychology Software Tools, Inc. Hyperion projector on a 60.0 cm (width) × 45.0 cm (height) screen with a resolution of 1,024 × 768 pixels at 60 Hz.



    Similar Products

    90
    Scherf GmbH visual stimulation task
    Visual Stimulation Task, supplied by Scherf GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/visual+stimulation+task/visual+cortex/pmc06865463-286-1-13
    Average 90 stars, based on 1 article reviews
    visual stimulation task - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    MathWorks Inc dynamic visual stimulation task
    Patients with fibromyalgia report increased affective unpleasantness in response to visual <t>stimulation.</t> (A) A dynamic visual stimulus was presented to individuals with fibromyalgia and healthy controls wherein participants viewed a 3-minute movie clip of alternating 20-second blocks of a flashing (8 Hz) blue-yellow annulus checkerboard (left panel) and a static fixation cross (right panel). The checkerboard was presented in increasing illumination levels, ranging from 4.5 to 78 lux. (B) Participants rated the unpleasantness evoked by the visual stimulus at each illumination level (left panel), and the overall unpleasantness of the entire visual task (right panel). FM = patients with fibromyalgia; HC = healthy control participants. *Significant pairwise comparisons.
    Dynamic Visual Stimulation Task, supplied by MathWorks Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/visual+stimulation+task/pmc04988086-38-4-10
    Average 90 stars, based on 1 article reviews
    dynamic visual stimulation task - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    Patients with fibromyalgia report increased affective unpleasantness in response to visual stimulation. (A) A dynamic visual stimulus was presented to individuals with fibromyalgia and healthy controls wherein participants viewed a 3-minute movie clip of alternating 20-second blocks of a flashing (8 Hz) blue-yellow annulus checkerboard (left panel) and a static fixation cross (right panel). The checkerboard was presented in increasing illumination levels, ranging from 4.5 to 78 lux. (B) Participants rated the unpleasantness evoked by the visual stimulus at each illumination level (left panel), and the overall unpleasantness of the entire visual task (right panel). FM = patients with fibromyalgia; HC = healthy control participants. *Significant pairwise comparisons.

    Journal: Pain

    Article Title: Pharmacologic attenuation of cross-modal sensory augmentation within the chronic pain insula

    doi: 10.1097/j.pain.0000000000000593

    Figure Lengend Snippet: Patients with fibromyalgia report increased affective unpleasantness in response to visual stimulation. (A) A dynamic visual stimulus was presented to individuals with fibromyalgia and healthy controls wherein participants viewed a 3-minute movie clip of alternating 20-second blocks of a flashing (8 Hz) blue-yellow annulus checkerboard (left panel) and a static fixation cross (right panel). The checkerboard was presented in increasing illumination levels, ranging from 4.5 to 78 lux. (B) Participants rated the unpleasantness evoked by the visual stimulus at each illumination level (left panel), and the overall unpleasantness of the entire visual task (right panel). FM = patients with fibromyalgia; HC = healthy control participants. *Significant pairwise comparisons.

    Article Snippet: Participants underwent a 3-minute dynamic visual stimulation task developed in MATLAB (Mathworks, Natick, MA) that consisted of alternating 20-second blocks of a flashing (8 Hz frequency) blue-yellow annulus checkerboard and a static fixation cross (Fig. A).

    Techniques: Control

    Journal: Pain

    Article Title: Pharmacologic attenuation of cross-modal sensory augmentation within the chronic pain insula

    doi: 10.1097/j.pain.0000000000000593

    Figure Lengend Snippet: Age, clinical pain, and responses to experimental sensory stimulation.

    Article Snippet: Participants underwent a 3-minute dynamic visual stimulation task developed in MATLAB (Mathworks, Natick, MA) that consisted of alternating 20-second blocks of a flashing (8 Hz frequency) blue-yellow annulus checkerboard and a static fixation cross (Fig. A).

    Techniques:

    Increased brain activation in response to aversive visual stimulation is associated with clinical pain intensity in fibromyalgia. (A) Individuals with fibromyalgia (FM) displayed greater functional magnetic resonance imaging blood–oxygen-level-dependent (BOLD) activations in right anterior insula than healthy controls (HC) during the presentation of a dynamic visual stressor. (B) Within the FM group, anterior insular activation was positively correlated with the degree of clinical pain measured using a 100-mm visual analog scale (VAS). IC, insular cortex.

    Journal: Pain

    Article Title: Pharmacologic attenuation of cross-modal sensory augmentation within the chronic pain insula

    doi: 10.1097/j.pain.0000000000000593

    Figure Lengend Snippet: Increased brain activation in response to aversive visual stimulation is associated with clinical pain intensity in fibromyalgia. (A) Individuals with fibromyalgia (FM) displayed greater functional magnetic resonance imaging blood–oxygen-level-dependent (BOLD) activations in right anterior insula than healthy controls (HC) during the presentation of a dynamic visual stressor. (B) Within the FM group, anterior insular activation was positively correlated with the degree of clinical pain measured using a 100-mm visual analog scale (VAS). IC, insular cortex.

    Article Snippet: Participants underwent a 3-minute dynamic visual stimulation task developed in MATLAB (Mathworks, Natick, MA) that consisted of alternating 20-second blocks of a flashing (8 Hz frequency) blue-yellow annulus checkerboard and a static fixation cross (Fig. A).

    Techniques: Activation Assay, Functional Assay, Magnetic Resonance Imaging

    Specific attenuation of insular response to aversive visual stimulation by pregabalin. (A) A subset of 17 patients with fibromyalgia underwent aversive visual stimulation during functional magnetic resonance imaging (fMRI) both before and after pregabalin and placebo administration. After the pregabalin period, a significant reduction in bilateral insular blood–oxygen-level-dependent (BOLD) activation in response to the visual stimulus was observed (left). No reductions in insular activation were observed after placebo treatment (right). Lines denote fMRI BOLD values for each participant (pre and post drug or placebo). Blue lines represent individuals with a decrease in BOLD activity, whereas red lines denote increases in BOLD activity. (B) A direct contrast between pregabalin and placebo periods shows decreased visual stimulus-evoked BOLD response in the right insula after pregabalin treatment.

    Journal: Pain

    Article Title: Pharmacologic attenuation of cross-modal sensory augmentation within the chronic pain insula

    doi: 10.1097/j.pain.0000000000000593

    Figure Lengend Snippet: Specific attenuation of insular response to aversive visual stimulation by pregabalin. (A) A subset of 17 patients with fibromyalgia underwent aversive visual stimulation during functional magnetic resonance imaging (fMRI) both before and after pregabalin and placebo administration. After the pregabalin period, a significant reduction in bilateral insular blood–oxygen-level-dependent (BOLD) activation in response to the visual stimulus was observed (left). No reductions in insular activation were observed after placebo treatment (right). Lines denote fMRI BOLD values for each participant (pre and post drug or placebo). Blue lines represent individuals with a decrease in BOLD activity, whereas red lines denote increases in BOLD activity. (B) A direct contrast between pregabalin and placebo periods shows decreased visual stimulus-evoked BOLD response in the right insula after pregabalin treatment.

    Article Snippet: Participants underwent a 3-minute dynamic visual stimulation task developed in MATLAB (Mathworks, Natick, MA) that consisted of alternating 20-second blocks of a flashing (8 Hz frequency) blue-yellow annulus checkerboard and a static fixation cross (Fig. A).

    Techniques: Functional Assay, Magnetic Resonance Imaging, Activation Assay, Activity Assay