Review




Structured Review

Fisher Scientific live dead viability cytotoxicity kit
Cell-scaffold interaction <t>(A)</t> <t>Live/Dead</t> staining of L-929 fibroblast cultures after 3 and 7 days in 2D conditions and on top of RTU scaffolds rehydrated with PBS and PRGF, respectively (scale bars, 100 μm). Biocompatibility assessment following ISO 10993 standards, evaluated by both direct contact (B) and extract-based (C) assays on L-929 fibroblasts. Cell adhesion and proliferation: SEM imaging and quantification of HDF fibroblast adhesion 24 h post-seeding on the scaffolds (D), followed by proliferation assessment after 72 h (E). Statistical significance is indicated as follows: not significant (ns); ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, and ∗∗∗∗ p < 0.0001.
Live Dead Viability Cytotoxicity Kit, supplied by Fisher Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/cytotoxicity+dead+kit+live+viability/pmc13264137-31-0-4
Average 86 stars, based on 1 article reviews
live dead viability cytotoxicity kit - by Bioz Stars, 2026-11
86/100 stars

Images

1) Product Images from "Ready-to-use 3D bioprinted scaffolds from natural materials loaded with patient’s PRGF for personalized skin regeneration"

Article Title: Ready-to-use 3D bioprinted scaffolds from natural materials loaded with patient’s PRGF for personalized skin regeneration

Journal: iScience

doi: 10.1016/j.isci.2026.116185

Cell-scaffold interaction (A) Live/Dead staining of L-929 fibroblast cultures after 3 and 7 days in 2D conditions and on top of RTU scaffolds rehydrated with PBS and PRGF, respectively (scale bars, 100 μm). Biocompatibility assessment following ISO 10993 standards, evaluated by both direct contact (B) and extract-based (C) assays on L-929 fibroblasts. Cell adhesion and proliferation: SEM imaging and quantification of HDF fibroblast adhesion 24 h post-seeding on the scaffolds (D), followed by proliferation assessment after 72 h (E). Statistical significance is indicated as follows: not significant (ns); ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, and ∗∗∗∗ p < 0.0001.
Figure Legend Snippet: Cell-scaffold interaction (A) Live/Dead staining of L-929 fibroblast cultures after 3 and 7 days in 2D conditions and on top of RTU scaffolds rehydrated with PBS and PRGF, respectively (scale bars, 100 μm). Biocompatibility assessment following ISO 10993 standards, evaluated by both direct contact (B) and extract-based (C) assays on L-929 fibroblasts. Cell adhesion and proliferation: SEM imaging and quantification of HDF fibroblast adhesion 24 h post-seeding on the scaffolds (D), followed by proliferation assessment after 72 h (E). Statistical significance is indicated as follows: not significant (ns); ∗ p < 0.05, ∗∗ p < 0.01, ∗∗∗ p < 0.001, and ∗∗∗∗ p < 0.0001.

Techniques Used: Staining, Imaging

Related Articles

Staining:

Article Title: Protocol for developing a mucus-producing gut-on-a-chip model from Caco-2 and HT29-MTX-E12 cells
Article Snippet: ActinRed 555 ReadyProbes Reagent , Thermo Fisher Scientific , 2525759. .. EprediaTM Alcian Blue/PAS Special Stain Kit , Fisher Scientific , 23-900-664. .. Cell counting kit-8 , Sigma-Aldrich , 96992-500TESTS-F.

Article Title: Geometry-driven control of bacterial adhesion and corrosion performance on LIPSS-textured 316 L stainless steel
Article Snippet: .. Following incubation, the substrates were gently rinsed with sterile DI water to remove loosely attached bacteria and stained for 15 min with the LIVE/ DEAD BacLight bacterial viability kit (L13152, Fisher Scientific, UK) at room temperature in the dark. .. Bacterial adhesion and viability were assessed via fluorescence microscopy (OLYMPUS BX 41, Japan) and quantified using image processing software (Image-Pro Plus, Media Cybernetics, USA).

Article Title: Ketone ester supplementation in aged mice reduces activation of B cell subsets
Article Snippet: .. Cells were transferred to 96-well V-bottom plates in PBS and stained with Live/Dead Blue (Fisher Scientific #L23105) for 10 minutes at 4oC. ..

Article Title: Uncovering the mechanisms of clinically relevant altered antibiotic responses of Staphylococcus aureus under wound infection-mimetic conditions.
Article Snippet: RT-PCR was performed using the QuantStudioTM 5 Real-Time PCR (Thermo Fisher Scientific) with FastStart SYBR Green (Roche). .. Gels were washed three times with ultrapure water, then stained with Alcian Blue 8GX (Fisher Scientific, 1 mg/mL) overnight, and destained with ultrapure water until the bands became visible. ..

Article Title: In Vivo Study of Osseointegrable Bone Calcium Phosphate (CaP) Implants Coated with a Vanillin Derivative
Article Snippet: For it, 24-well plates (Sarstedt), equipped with sterile glass disks, were filled with 1 mL of TSBG, inoculated with 20 μL of the inoculum suspension with final inoculum of approximately 1 × 10 3 CFU/mL and was grown for 24 h at 37 °C in presence of CaP or CaP-Vanillin. .. After three washes with 500 μL of sterile PBS, bacterial cells were stained using the InvitrogenTM LIVE/DEADTM BacLightTM Bacterial Viability kit (Fisher Scientific, Madrid, Spain) according to the manufacturer’s protocol. .. For it, 24-well plates (Sarstedt), equipped with sterile glass disks, were filled with 1 mL of TSBG, inoculated with 20 μL of the inoculum suspension with final inoculum of approximately 1 × 10 3 CFU/mL and was grown for 24 h at 37 °C in presence of CaP or CaP-Vanillin.

Article Title: Immunogenicity and protection mediated by dmLT and alum adjuvants for an HIV-1 vaccine
Article Snippet: .. All steps were the same as above except that the live/dead stain (Fisher Scientific, # L34976 ) was included in the surface marker stain (full panel can be found in ). ..

Article Title: In Vivo Study of Osseointegrable Bone Calcium Phosphate (CaP) Implants Coated with a Vanillin Derivative.
Article Snippet: For it, 24-well plates (Sarstedt), equipped with sterile glass disks, were filled with 1 mL of TSBG, inoculated with 20 μL of the inoculum suspension with final inoculum of approximately 1 × 103 CFU/mL and was grown for 24 h at 37 ◦C in presence of CaP or CaP-Vanillin. .. After three washes with 500 μL of sterile PBS, bacterial cells were stained using the InvitrogenTM LIVE/DEADTM BacLightTM Bacterial Viability kit (Fisher Scientific, Madrid, Spain) according to the manufacturer’s protocol. ..

Incubation:

Article Title: Geometry-driven control of bacterial adhesion and corrosion performance on LIPSS-textured 316 L stainless steel
Article Snippet: .. Following incubation, the substrates were gently rinsed with sterile DI water to remove loosely attached bacteria and stained for 15 min with the LIVE/ DEAD BacLight bacterial viability kit (L13152, Fisher Scientific, UK) at room temperature in the dark. .. Bacterial adhesion and viability were assessed via fluorescence microscopy (OLYMPUS BX 41, Japan) and quantified using image processing software (Image-Pro Plus, Media Cybernetics, USA).

Sterility:

Article Title: Geometry-driven control of bacterial adhesion and corrosion performance on LIPSS-textured 316 L stainless steel
Article Snippet: .. Following incubation, the substrates were gently rinsed with sterile DI water to remove loosely attached bacteria and stained for 15 min with the LIVE/ DEAD BacLight bacterial viability kit (L13152, Fisher Scientific, UK) at room temperature in the dark. .. Bacterial adhesion and viability were assessed via fluorescence microscopy (OLYMPUS BX 41, Japan) and quantified using image processing software (Image-Pro Plus, Media Cybernetics, USA).

Article Title: In Vivo Study of Osseointegrable Bone Calcium Phosphate (CaP) Implants Coated with a Vanillin Derivative
Article Snippet: For it, 24-well plates (Sarstedt), equipped with sterile glass disks, were filled with 1 mL of TSBG, inoculated with 20 μL of the inoculum suspension with final inoculum of approximately 1 × 10 3 CFU/mL and was grown for 24 h at 37 °C in presence of CaP or CaP-Vanillin. .. After three washes with 500 μL of sterile PBS, bacterial cells were stained using the InvitrogenTM LIVE/DEADTM BacLightTM Bacterial Viability kit (Fisher Scientific, Madrid, Spain) according to the manufacturer’s protocol. .. For it, 24-well plates (Sarstedt), equipped with sterile glass disks, were filled with 1 mL of TSBG, inoculated with 20 μL of the inoculum suspension with final inoculum of approximately 1 × 10 3 CFU/mL and was grown for 24 h at 37 °C in presence of CaP or CaP-Vanillin.

Article Title: In Vivo Study of Osseointegrable Bone Calcium Phosphate (CaP) Implants Coated with a Vanillin Derivative.
Article Snippet: For it, 24-well plates (Sarstedt), equipped with sterile glass disks, were filled with 1 mL of TSBG, inoculated with 20 μL of the inoculum suspension with final inoculum of approximately 1 × 103 CFU/mL and was grown for 24 h at 37 ◦C in presence of CaP or CaP-Vanillin. .. After three washes with 500 μL of sterile PBS, bacterial cells were stained using the InvitrogenTM LIVE/DEADTM BacLightTM Bacterial Viability kit (Fisher Scientific, Madrid, Spain) according to the manufacturer’s protocol. ..

Bacteria:

Article Title: Geometry-driven control of bacterial adhesion and corrosion performance on LIPSS-textured 316 L stainless steel
Article Snippet: .. Following incubation, the substrates were gently rinsed with sterile DI water to remove loosely attached bacteria and stained for 15 min with the LIVE/ DEAD BacLight bacterial viability kit (L13152, Fisher Scientific, UK) at room temperature in the dark. .. Bacterial adhesion and viability were assessed via fluorescence microscopy (OLYMPUS BX 41, Japan) and quantified using image processing software (Image-Pro Plus, Media Cybernetics, USA).

Marker:

Article Title: Immunogenicity and protection mediated by dmLT and alum adjuvants for an HIV-1 vaccine
Article Snippet: .. All steps were the same as above except that the live/dead stain (Fisher Scientific, # L34976 ) was included in the surface marker stain (full panel can be found in ). ..



Similar Products

95
Vazyme Biotech Co cell counting lite 2 0 luminescent cell viability assay
Cell Counting Lite 2 0 Luminescent Cell Viability Assay, supplied by Vazyme Biotech Co, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/CellCounting-Lite+2%2E0+Luminescent+Cell+Viability+Assay/pm43003801-309-0-9
Average 95 stars, based on 1 article reviews
cell counting lite 2 0 luminescent cell viability assay - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

99
Dojindo Labs viability
Viability, supplied by Dojindo Labs, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Cell+Counting+Kit-8/pmc13004575-101-0-8
Average 99 stars, based on 1 article reviews
viability - by Bioz Stars, 2026-11
99/100 stars
  Buy from Supplier

97
Beyotime calcein pi cell viability cytotoxicity assay kit
Calcein Pi Cell Viability Cytotoxicity Assay Kit, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pmc13763943-232-2-32
Average 97 stars, based on 1 article reviews
calcein pi cell viability cytotoxicity assay kit - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

94
Beyotime celltiter lumi plus luminescent cell viability assay kit
Celltiter Lumi Plus Luminescent Cell Viability Assay Kit, supplied by Beyotime, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/CellTiter-Lumi+Plus+Luminescent+Cell+Viability+Assay+Kit/pmc13758398-294-54-61
Average 94 stars, based on 1 article reviews
celltiter lumi plus luminescent cell viability assay kit - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

97
Beyotime calcein am pi kit
Calcein Am Pi Kit, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pmc13748765-248-6-44
Average 97 stars, based on 1 article reviews
calcein am pi kit - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

97
Beyotime calcein am pi
Calcein Am Pi, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pmc13749005-251-2-12
Average 97 stars, based on 1 article reviews
calcein am pi - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

95
Vazyme Biotech Co cellcounting lite 2 0 luminescent cell viability assay
Cellcounting Lite 2 0 Luminescent Cell Viability Assay, supplied by Vazyme Biotech Co, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/CellCounting-Lite+2%2E0+Luminescent+Cell+Viability+Assay/pm42956743-882-97-103
Average 95 stars, based on 1 article reviews
cellcounting lite 2 0 luminescent cell viability assay - by Bioz Stars, 2026-11
95/100 stars
  Buy from Supplier

97
Beyotime calcein am propidium iodide pi
Calcein Am Propidium Iodide Pi, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pmc13745762-42-0-17
Average 97 stars, based on 1 article reviews
calcein am propidium iodide pi - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

97
Beyotime calcein am pi cell viability assay kit
Calcein Am Pi Cell Viability Assay Kit, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pm42998808-66-6-41
Average 97 stars, based on 1 article reviews
calcein am pi cell viability assay kit - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

97
Beyotime calcein pi cell viability
Calcein Pi Cell Viability, supplied by Beyotime, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/viability/Calcein%2FPI+Cell+Viability%2FCytotoxicity+Assay+Kit/pmc13757693-177-6-13
Average 97 stars, based on 1 article reviews
calcein pi cell viability - by Bioz Stars, 2026-11
97/100 stars
  Buy from Supplier

Image Search Results