Review



massarray typeranalyzer v3.3 software  (Sequenom)

 
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Sequenom massarray typeranalyzer v3.3 software
    Massarray Typeranalyzer V3.3 Software, supplied by Sequenom, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/typeranalyzer+software/massarray+assay+design+3+0+software/pmc02405805-201-7-11
    Average 90 stars, based on 1 article reviews
    massarray typeranalyzer v3.3 software - by Bioz Stars, 2026-11
    90/100 stars

    Images

    Related Articles

    Polymerase Chain Reaction:

    Article Title: Association of iron homeostasis-related gene polymorphisms with pregnancy and neonatal outcomes in patients with gestational diabetes mellitus
    Article Snippet: .. Sequenom Genotyping Tools and MassArray Assay Design were used to design PCR amplification primers and single-base extension primers for the test site. ..

    Amplification:

    Article Title: Association of iron homeostasis-related gene polymorphisms with pregnancy and neonatal outcomes in patients with gestational diabetes mellitus
    Article Snippet: .. Sequenom Genotyping Tools and MassArray Assay Design were used to design PCR amplification primers and single-base extension primers for the test site. ..

    other:

    Article Title: Frequency of Tumor Necrosis Factor-α, Interleukin-6, and Interleukin-10 Gene Polymorphisms in Mexican Patients with Diabetic Retinopathy and Diabetic Kidney Disease.
    Article Snippet: The 4 PCR primer pairs and 4 probes for TNF-α rs361525, TNF-α rs1800629, IL-10 rs1800872, and IL-10 rs1800871 were designed using MassARRAY Assay Design v 3.1 software (Sequenom, Inc., San Diego, CA, USA) with the following design parameters: locus-specific primer sizes between 12 and 30 nucleotides, average sizes of amplicons between 80 and 120 base pairs (bp), an annealing temperature between 45 and 100 ◦C, optimal robustness of 0.8 in loop formation, dimers and false amplification primers, average robustness in dimer formation and false primer extension of 0.5, a spectrometric range of 4 to 10 kDa, a separation distance between SNPs of 15 Da, and a maximum multiplexing number of 8 SNPs.

    Article Title: FCRL3 genetic variants drive autoimmune pathogenesis in multiple sclerosis and neuromyelitis optica spectrum disorders
    Article Snippet: PCR and extension primers were designed using MassArray Assay Design 3.1 software (Sequenom, San Diego, CA, USA) ( ).

    Article Title: Frequency of Tumor Necrosis Factor-α, Interleukin-6, and Interleukin-10 Gene Polymorphisms in Mexican Patients with Diabetic Retinopathy and Diabetic Kidney Disease
    Article Snippet: The 4 PCR primer pairs and 4 probes for TNF-α rs361525, TNF-α rs1800629, IL-10 rs1800872, and IL-10 rs1800871 were designed using MassARRAY Assay Design v 3.1 software (Sequenom, Inc., San Diego, CA, USA) with the following design parameters: locus-specific primer sizes between 12 and 30 nucleotides, average sizes of amplicons between 80 and 120 base pairs (bp), an annealing temperature between 45 and 100 °C, optimal robustness of 0.8 in loop formation, dimers and false amplification primers, average robustness in dimer formation and false primer extension of 0.5, a spectrometric range of 4 to 10 kDa, a separation distance between SNPs of 15 Da, and a maximum multiplexing number of 8 SNPs.

    Mass Spectrometry:

    Article Title: Interactions between ABC gene polymorphisms and processing speed in predicting depression severity
    Article Snippet: .. Peripheral blood DNA was extracted using Trizol technology, and genotyping was conducted using the MassARRAY ® Analyzer 4 platform (Sequenom, San Diego, CA) employing matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry. .. Allele and genotype frequency analyses were performed using R studio version (4.0.2).



    Similar Products

    90
    agena bioscience typeranalyzer® software
    Typeranalyzer® Software, supplied by agena bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/typeranalyzer+software/typer+analyzer+software+version+4+0+147/pm40050386-202-12-16
    Average 90 stars, based on 1 article reviews
    typeranalyzer® software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    agena bioscience massarray typeranalyzer 4.1 software
    Massarray Typeranalyzer 4.1 Software, supplied by agena bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/typeranalyzer+software/massarray+typeranalyzer+4+1+software/pmc11239497__41559_2024_2436_MOESM1_ESM-327-22-15
    Average 90 stars, based on 1 article reviews
    massarray typeranalyzer 4.1 software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Sequenom massarray typeranalyzer software version 4.0
    Massarray Typeranalyzer Software Version 4.0, supplied by Sequenom, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/typeranalyzer+software/massarray+assay+design+3+0+software/pm36632909-69-20-25
    Average 90 stars, based on 1 article reviews
    massarray typeranalyzer software version 4.0 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Sequenom massarray typeranalyzer v3.3 software
    Massarray Typeranalyzer V3.3 Software, supplied by Sequenom, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/typeranalyzer+software/massarray+assay+design+3+0+software/pmc02405805-201-7-11
    Average 90 stars, based on 1 article reviews
    massarray typeranalyzer v3.3 software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Sequenom typeranalyzer 4.0 software
    This figure shows the 4 steps of the SNPflow data analysis wizard. In brief, the first step allows the uploading of either SDS files (ABI 7900HT) or TyperAnalyzer 4.0 (MassARRAY) files. For TyperAnalyzer files, a second input field asks for the name of the result group under which results shall be grouped. The second step checks the validity of the IDs found in the uploaded and reports IDs, which are not found in the study definition and shall thus be deleted. Step 3 converts the found genotype designations to standard genotypes and allows entering the name of the result, the operator name, an optional comment and the rs-number of the SNP in HapMap and the 1000 Genomes Project. This is useful in case that a SNP ID changed between the current dbSNP release and the dbSNP release used in HapMap, as happened for some SNPs. For convenience, the result name is automatically pre-set as HapMap lookup. In multiplex assays, pagination allows navigating through the single SNPs. For quality reasons a manual confirmation of each conversion is required (Checkbox “All settings are correct”). Finally, step 4 confirms the successful analysis and brings the user to the report. Exemplary abbreviation used in this figure: NTC, Non-template control; ER, annulled samples (“error”), i.e. DNA samples present on the plates, but known to be flawed. The IDs of these samples were thus replaced with “ER” in order to avoid data collection for these samples.
    Typeranalyzer 4.0 Software, supplied by Sequenom, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/typeranalyzer+software/typeranalyzer+4+0+software/pmc03602247-61-12-11
    Average 90 stars, based on 1 article reviews
    typeranalyzer 4.0 software - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results


    This figure shows the 4 steps of the SNPflow data analysis wizard. In brief, the first step allows the uploading of either SDS files (ABI 7900HT) or TyperAnalyzer 4.0 (MassARRAY) files. For TyperAnalyzer files, a second input field asks for the name of the result group under which results shall be grouped. The second step checks the validity of the IDs found in the uploaded and reports IDs, which are not found in the study definition and shall thus be deleted. Step 3 converts the found genotype designations to standard genotypes and allows entering the name of the result, the operator name, an optional comment and the rs-number of the SNP in HapMap and the 1000 Genomes Project. This is useful in case that a SNP ID changed between the current dbSNP release and the dbSNP release used in HapMap, as happened for some SNPs. For convenience, the result name is automatically pre-set as HapMap lookup. In multiplex assays, pagination allows navigating through the single SNPs. For quality reasons a manual confirmation of each conversion is required (Checkbox “All settings are correct”). Finally, step 4 confirms the successful analysis and brings the user to the report. Exemplary abbreviation used in this figure: NTC, Non-template control; ER, annulled samples (“error”), i.e. DNA samples present on the plates, but known to be flawed. The IDs of these samples were thus replaced with “ER” in order to avoid data collection for these samples.

    Journal: PLoS ONE

    Article Title: SNPflow: A Lightweight Application for the Processing, Storing and Automatic Quality Checking of Genotyping Assays

    doi: 10.1371/journal.pone.0059508

    Figure Lengend Snippet: This figure shows the 4 steps of the SNPflow data analysis wizard. In brief, the first step allows the uploading of either SDS files (ABI 7900HT) or TyperAnalyzer 4.0 (MassARRAY) files. For TyperAnalyzer files, a second input field asks for the name of the result group under which results shall be grouped. The second step checks the validity of the IDs found in the uploaded and reports IDs, which are not found in the study definition and shall thus be deleted. Step 3 converts the found genotype designations to standard genotypes and allows entering the name of the result, the operator name, an optional comment and the rs-number of the SNP in HapMap and the 1000 Genomes Project. This is useful in case that a SNP ID changed between the current dbSNP release and the dbSNP release used in HapMap, as happened for some SNPs. For convenience, the result name is automatically pre-set as HapMap lookup. In multiplex assays, pagination allows navigating through the single SNPs. For quality reasons a manual confirmation of each conversion is required (Checkbox “All settings are correct”). Finally, step 4 confirms the successful analysis and brings the user to the report. Exemplary abbreviation used in this figure: NTC, Non-template control; ER, annulled samples (“error”), i.e. DNA samples present on the plates, but known to be flawed. The IDs of these samples were thus replaced with “ER” in order to avoid data collection for these samples.

    Article Snippet: SNPflow is able to deal with results coming both from the Sequenom TyperAnalyzer 4.0 software and the ABI SDS software version 2.2.2, since these two platforms are present in our laboratory and we were thus able to implement SNPflow respectively.

    Techniques: Multiplex Assay