1) Product Images from "Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) Improves Chest CT Image Quality and Reduces Radiation Exposure"
Article Title: Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) Improves Chest CT Image Quality and Reduces Radiation Exposure
Journal: PLoS ONE
doi: 10.1371/journal.pone.0105735
Figure Legend Snippet: Results of qualitative scores* for image quality at different tube currents with AIDR3D and FBP (without AIDR3D).
Techniques Used:
Figure Legend Snippet: These images were created from scan data at 240 mA ( A, D ), 120 mA ( B, E ) and 60 mA ( C, F ). The three upper images ( A–C ) were reconstructed using AIDR3D and the three lower images ( D–F ) were reconstructed using a conventional reconstruction mode (Boost3D). Each image pair at the same tube current was created from single row data. Image noise was obviously reduced on images with AIDR3D, particularly at lower tube currents.
Techniques Used:
Figure Legend Snippet: Images are arranged as in ( A–C , with AIDR3D; D–F , without AIDR3D; A and D , at 240 mA; B and E , at 120 mA; C and F , at 60 mA). Severe image noise was observed at the upper lung zones and bottoms at 120 and 60 mA without AIDR3D ( E and F ), which was obviously improved using AIDR3D ( B and C ).
Techniques Used:
Figure Legend Snippet: Images are arranged as in and . Spiculae were found on all images, while density heterogeneity inside the mass was severe on images at 60 mA without AIDR3D ( F ).
Techniques Used:
Figure Legend Snippet: Images are arranged as in and . Nearly homogeneous density of the nodule was accurately depicted on images with AIDR3D at any of three tube currents ( A–C ). However, on images without AIDR3D ( D–F) , artificial density heterogeneity due to image noise increased as the tube current decreased from 240 ( D ) to 60 mA ( F ).
Techniques Used:
Figure Legend Snippet: , at 240 mA with AIDR3D; B , at 120 mA with AIDR3D; C , at 60 mA with AIDR3D; D , at 240 mA without AIDR3D; E , at 120 mA without AIDR3D; F , at 60 mA without AIDR3D. Many radial streaks from the spine were apparent in the heart, particularly on the image without AIDR3D at 60 mA ( F ). These streaks were greatly reduced using AIDR3D ( C , at 60 mA).
Techniques Used:
* ) at different tube currents with AIDR3D and FBP (without AIDR3D). " title="... different tube currents with AIDR3D and FBP (without AIDR3D). " property="contentUrl" width="100%" height="100%"/>
Figure Legend Snippet: Results of quantitative image noise (SD measurement
Techniques Used:
Figure Legend Snippet: Results of phantom study at different tube currents with AIDR3D and FBP (without AIDR3D).
Techniques Used:
Related Articles
other:Article Title: Deep Learning-Based Image Reconstruction for Different Medical Imaging Modalities Article Snippet: AIDR 3D , Article Title: Identification of Risk Factors for Coronary Artery Disease in Asymptomatic Patients with Type 2 Diabetes Mellitus Article Snippet: Control:Article Title: Challenging Cases of Aortic Prosthesis Dysfunction, the Importance of Multimodality Imaging, a Case Series Article Snippet: CT was performed with axial imaging using a third-generation 320 × 0.5-mm detector row CT unit (Aquilion ONE ViSION Edition; Toshiba Medical Systems, Otawara, Japan). .. Gantry rotation time: 350 ms; automatic exposure control (SURE bExposure 3D, Toshiba Medical Systems, SD 110 for contrast-enhanced images); 512 × 512 matrix; retrospective protocol; section thickness of 0.5 mm with 0.25 mm increments using kernel FC03; |