high-performance, automatic adsorbed gas amount measuring device ac-1-c/vp/tcd/ms (Quantachrome gmbh)
Structured Review
High Performance, Automatic Adsorbed Gas Amount Measuring Device Ac 1 C/Vp/Tcd/Ms, supplied by Quantachrome gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tcd+device/high+performance++automatic+adsorbed+gas+amount+measuring+device+ac+1+c+vp+tcd+ms/us10103387-93-32-42
Average 90 stars, based on 1 article reviews
Images
Related Articles
other:Article Title: Method for producing fuel cell catalyst layer Article Snippet: S=A×vm×N/W Formula (2) S: Specific surface area A: Sectional area of adsorbed molecule N: Avogadro's number W: Amount of sample vm: Amount of adsorbed monolayer (Measurement of Adsorbed Ammonia Amount) Measurement device: High-performance, automatic adsorbed gas amount measuring |

![Fig. 3. Efficacy of scaled-up <t>TCD</t> <t>device</t> for microbial inactivation. (A) Schematic of microbial inactivation process using the scaled-up TCD device, where aerosols containing bacteria or viruses are dispersed on the device surface after charge injection. (B) Microbial inactivation efficiency for different model microorganisms [E. coli (gram-negative bacterium), B. subtilis (gram-positive bacterium), and MS2 bacteriophage (virus)]. (C) Effect of graphene on the microbial inactivation efficiency. No charg- ing voltage is applied to the device. (D) Effect of charging voltage on microbial inactivation efficiency. (E) Images showing the concentration of E. coli (left), B. subtilis (middle), and MS2 (right) at charging voltages of 20 and 1 V using the scaled-up TCD device. (F) Effect of humidity (up to 90%) and temperature (up to 60°C) on the effi- cacy of the TCD device for E. coli inactivation after 48 and 72 hours. (G) Efficacy of TCD device for bacterial inactivation when treating intermittently applied aerosols containing E. coli or B. subtilis. In (B) to (E), the experiment is performed at a fixed temperature (20°C) and humidity (30%). In (E) to (G), the TCD device is charged to 10 V, and microorganisms are measured after 1 min of attachment. Dashed lines indicate that all microorganisms are inactivated (i.e., no live microorganisms detected). Error bars represent SD (n = 3). Significant differences among groups are indicated by * and ** for P < 0.05 and P < 0.01, respectively.](https://pub-med-unpaywalled-images-cdn.bioz.com/pub_med_ids_ending_with_1201/pm38701201/pm38701201__page5_image1.jpg)